l <br /> ACTON • <br /> MICKELSON • <br /> van DAM, INC. <br /> Consulting Scientists,Engineers,and Geologists <br /> RECEI Eu" <br /> May 20, 1994 MAY 111 1994 <br /> ENVIRONMENTAL HEALTH <br /> PERMIT/SERVICES <br /> Mr. Kenneth Earnest <br /> Ultramar Inc. <br /> 525 West Third Street <br /> Hanford, California 93230 19005.13 <br /> Subject: Start-Up and First Quarter 1994 Remediation Status Report--Beacon Station #494 <br /> Located at 2185 East Fremont Street, Stockton, California <br /> (Soil Vapor Extraction System) <br /> Dear Mr. Earnest: <br /> Acton • Mickelson • van Dam, Inc. (AMV), prepared this letter to document remediation <br /> activity at the referenced site during 1993 and the first quarter of 1994, specifically, the period <br /> from November 5, 1993 to March 25, 1994. Table 1 summarizes the system performance. <br /> Figure 1 graphically presents hydrocarbon extraction rates versus time. <br /> AMV activated the oxidation unit briefly on October 28, 1993, in the presence of a <br /> representative of the San Joaquin Valley Unified Air Pollution Control District (San Joaquin <br /> APCD), for the purpose of demonstrating operation and collecting air samples to verify <br /> destruction efficiency. After San Joaquin APCD approval of the air sample analytical results, <br /> AMV started operation of the system on November 5, 1993. The system ran a total of 68 days- <br /> in the 140-dgy Loorting veriod ending March 25,_L994, Following is a month-by-month <br /> summary of activity. <br /> November 5 to 29, 1993 <br /> After start-up on November 5, 1993, the THERMTECH oxidation unit ran for about 19 days J <br /> out of the 24-day reporting period. High_hydrocarbon concentrations during the start-up phase <br /> made it necessary to supply dilution air from November 5 to 19, 1993. During the initial <br /> operational period, the system experienced four shutdowns. One of the shutdowns was caused <br /> by high temperature from the lack of sufficient dilution air, and the other three shutdowns were <br /> a result of a burner control failure. On November 29, 1993, the unit was left down in order to <br /> find a solution to the erratic performance of the burner control. During the reporting period, <br /> the system extracted an estimated 5,133 pounds of h droc (based on field readings). The <br /> laboratory results for an influent air sample collected on October 28, 1993, indicated an average <br /> kpwao.m; <br /> 4511 Golden Foothill Parkway,Suite 1 (916)939-7550 <br /> El Dorado Hills,California 95762 Fax(916) 939-7570 <br />