Laserfiche WebLink
STI Aboveground Storage Tank Report Formal External Inspection COVEY AUTO EXPRESS,Stockton,CA <br /> Storage Tank Report 1/21/2014 Tank No.4—Used Oil Weather: Clear moderate <br /> Inspection Goal Methods Employed Results <br /> 7,2 DETERMINE ORIGINAL SHELL THICKNESS <br /> 7.2.1 Review original documentation. Not Available <br /> 7.2.2 Consult tank manufacturer. <br /> 7.2.3 Examine tank labels for evidence of widely accepted tank <br /> standard,such as Underwriters Laboratories Standard UL142. <br /> 7,2.4 Measure shell thickness of several areas with no corrosion 0.072-0.077 IN,14 ga <br /> measured UTT <br /> 7.3 HORIZONTAL AST Requirements in addition to applicable items in 71: HOR(ZOWAL <br /> 7.3.1 Inspect shell plates, Inspect areas accessible without entering AST. Concentrate Sound OK Ultra Sonic <br /> welds where corrosion is likely.If significant internal corrosion is measurements,visible <br /> detected,further investigation using Ultrasonic Testing Scans underneath&on PCC floor <br /> (UTS)is required. <br /> 7,3,2 Inspect shell Inspect for changes made after AST was fabricated.Record 1-1/2"pipe legs w/casters <br /> attachments repads and/or insert plates.Inspect welds for signs of stress 4topside 2"NPT openings <br /> and corrosion. <br /> 7,4 VERTICAL-or Requirements in addition to applicable items in 7.1: N/A <br /> RECTANGULAR AST <br /> 7.4.1 Inspect shell plates, Inspect areas accessible without entering AST. Concentrate N/A <br /> welds where corrosion is likely.If significant internal corrosion is <br /> detected,further Investigation using UTS is required. <br /> 7,4.2 Inspect shell Inspect for changes made after AST was fabricated. Record N/A <br /> attachments repads and/or insert plates.Inspect welds for signs of stress <br /> and corrosion. <br /> 7,4,3 Vertical AST Roof Inspect for low areas,standing water,paint failure,holes and N/A <br /> corrosion.Take Ultrasonic Thickness Testing(UTT)readings on <br /> roof and record results. If significant internal corrosion is <br /> detected,further Investigation using UTS is required. <br /> 7.4.4 DOUBLE WALL& Requirements in addition to applicable items In 7.1: NIA <br /> DOUBLE BOTTOM AST <br /> 7.4.5 Leak Detection Verify that the leak detection equipment method is operating N/A <br /> if the tank Is so equipped. <br /> 7,4,6 Inspect Interstice Check for leak or liquid in Interstice,not vented to N!A <br /> atmosphere. <br /> 7,4,7 Double bottom Double-bottom ASTs require LITT readings of areas that are N/A <br /> single-wall.Double-wall ASTs do not require UTT readings. <br /> 7,5 INSULATED AST Requirements in addition to applicable Items In 7.1 to 7.4. N/A <br /> 7,5,1 Remove insulation Remove insulation in areas where mold or moisture is present N/A <br /> or likely to accumulate and examine metal surface for corrosion. <br /> 7,5,2 Verify damage extent If insulation damage Is suspected,remove insulation until N/A <br /> extent and nature of corrosion has been established. <br /> 7.5.3 Take UTT readings Take UTT readings on shell and record results. If significant N/A <br /> corrosion is detected,further investigation using UTS is <br /> required. <br /> 7.5.6 FIELD ERECTED AST Additional requirements for field-erected ASTs are included In N/A <br /> SPo01 Appendix B. <br /> 7,7 FINAL REPORT Include:Field data,measurements,pictures,drawings,tables Dated 1/21/14 Re-inspect <br /> and an inspection summary,identify unacceptable conditions in 5 years or as specified in <br /> and recommended corrective actions.Determine the SPCCP or hazardous waste <br /> suitability for continued service.Include the next scheduled regulations <br /> formal external or internal inspection as applicable.Include <br /> inspectors name and certification number in the report <br />