My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL 1993
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2185
>
2300 - Underground Storage Tank Program
>
PR0231118
>
REMOVAL 1993
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/21/2019 1:49:44 PM
Creation date
10/21/2019 1:38:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
1993
RECORD_ID
PR0231118
PE
2371
FACILITY_ID
FA0003284
FACILITY_NAME
FOOD MART GASOLINE*
STREET_NUMBER
2185
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
14113045
CURRENT_STATUS
01
SITE_LOCATION
2185 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNT 'ELIC HEALTH SERVICES/ENVIRONMENTAL HEALTH I 'TSION <br /> UGS RKSHEET FOR SITE CLOSURE EVALUATION DATE j v�j <br /> ME OF FACILITY �/�/ SWEEPS CODE elf G <br /> NA <br /> ^G C Ll�/ e4 +i cz -ZO <br /> TANK IO $ <br /> IADORESSI S6_ /:�7_ je' '-XIC' "j <br /> TANK SIZE /C-;,/ G F E _TYPE <br /> II. GE4ERAL SITE HISTORY +•+ <br /> Is permit current? Yes No Permit - Facility Status Code Doc.Soil/GW Cont Yes No <br /> Number of Tanks at facility Age of Tanks(if available) Type of Tank Steel Fbrgl Sngl Dual <br /> :II. TANK HISTORY <br /> Was Tank testedl Yes No Failed precision test 7 Yes No If yes, give dates) / <br /> Was a repair made to the tank system? Yes No if yes, what was repaired? <br /> Was repair done under inspection? Yes No Were soil sanples analyzed? Yes 'No BTXEI TPH-G TPH D Pb/EDB <br /> Type of failure/discharge catastrophic long-term leakage overfill unknown other: <br /> tV. REMOVAL HISTORY (ATTACH INSPECTION REPORT FOR SITE DETAILS/COLLECT DATA FOR LEACHING POTENTIAL ANALYSIS) <br /> Soil Samples Received Yes No Depth to Ground Water Ref/Year ; <br /> Average Arcual Precipitation A= 14 10-25 <br /> On-Site Wells) Yes No Number & Type Irr Dom Pub <br /> S Score S Score S Score <br /> Distance to Well(S) from Tank ft; ft; ft C 10 pts C 9 pts C 5 pts <br /> 0 if 0 if 0 if <br /> R condition R condition R condition <br /> V. Site Feature - Leaching Potential Analysis E is met E is net E is met <br /> Minimum Depth to groundwater from the Soil Sample (feet) <br /> >100 51-100 25-50\1 <br /> Fractures in subsurface (applies to foothills or mountain areas) <br /> None I Unknown Present <br /> Average Annual Precipitation (inches) <br /> xxxxxx <10 9 10-25 xxxxxxx 26-40\2 <br /> Man-Made conduits which increase vertical migration No Unknown Present <br /> of leachate (i.e., septic systems, water wells, ponds) <br /> At least More than <br /> Unique site features: Recharge area, coarse soil, nearby wells. xxxxxx None one one <br /> COLUMN TOTALS»>TOTAL POINTS <br /> LSampLelt• (B T X OR E) RANGE OF TOTAL POINTS 49 pts or more 41 - 48 pts 40 pts or less <br /> 31 T I X I E B T X E <br /> MAXIMUM ALLOWABLE B-T-X-E LEVELS (PPM) 1 50 50 50 .3 .3 1. 1. <br /> NA\3 <br /> GASOLINE 1000 100 10 <br /> Sample Result: <br /> MAXIMUM ALLOWABLE TPH LEVELS (PPM) 100 <br /> TPH DIESEL 10,000 1000 <br /> FOOTNOTES: ***If documented soil and/or ground water contamination is present, do not complete the leaching potential <br /> analysis. (i.e., site is currently on UGT Contamination List for soil or ground water.) <br /> \1 if depth is > 5 ft. and < 25 ft., score 0 points. If depth <=5 ft., do not use table. <br /> \2 If precipitation is > 40 inches, score 0 points. <br /> \3 Levels for BTX&E are not applicable at a TPH concentration of 10 ppm (gasoline) or 100 ppm (diesel). <br /> VI. STAFF RECOMMENDATION/CONCLUSION <br /> 1. Are BTX & E or TPH Concentrations > Allowable Levels *Yes No <br /> 2. Recommend Site Closure Yes No If Yes, Refer to Site Mitigation for Evaluation <br /> 11II. REVIEW EVALUATION - TO BE COMPLETED BY A SUPERVISOR/SENIOR <br /> CCNCUR WITH STAFF RECOMMENDATION FOR CLOSURE YES NO REFERRED TO SITE MITIGATION FOR EVALUATION YES NO <br /> DATE REFERRED / / DATE CLOSURE LETTER MAILED <br /> NAME OF <br /> EVALUATOR <br /> EH 23 N (UGTUKSHT) 5/90 <br />
The URL can be used to link to this page
Your browser does not support the video tag.