My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2185
>
2300 - Underground Storage Tank Program
>
PR0231118
>
COMPLIANCE INFO 2009 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2023 2:30:31 PM
Creation date
10/21/2019 2:23:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2018
RECORD_ID
PR0231118
PE
2371
FACILITY_ID
FA0003284
FACILITY_NAME
FOOD MART GASOLINE*
STREET_NUMBER
2185
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
14113045
CURRENT_STATUS
01
SITE_LOCATION
2185 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOOD MART GAS VAPOR VALVE THERMOMETER TEST <br />UST #1 <br />§7.3.2 <br />Vapor polisher ambient temperature <br />82.83 <br />Vapor polisher outlet temperature <br />75.49 <br />Difference between ambient and outlet temperatures <br />7.34 <br />Is the difference less than 10° F? If not, proceed to section 9.2.1 <br />Yes <br />§9.2.2 <br />Vapor polisher ambient temperature <br />Vapor polisher outlet temperature <br />Difference between ambient and outlet temperatures <br />Is the difference less than 10° F? If not, proceed to section 9.2.4 <br />UST 92 <br />§9.2.4 & §9.2.5 <br />Vapor polisher ambient temperature <br />82.228 <br />Vapor polisher outlet temperature <br />81.571 <br />Calibrated thermometer ambient temperatures <br />0.657 <br />Difference between outlet temperature and the calibrated thermometer <br />Yes <br />Is the difference less than 10° F? If not, the outlet thermometer does not meet specifications <br />§9.1 <br />Difference between ambient temperature and the calibrated thermometer <br />Is the difference less than 10° F? If not, the ambient thermometer does not meet specifications <br />UST THERMOMETER TEST <br />I declare, under penalty ofperjuiy under the laws of the state of C,'alijornia that based on informati <br />UST #1 <br />§7.3.3 <br />T5 temperature <br />82.055 <br />T4 temperature <br />81.829 <br />Difference between T5 and T4 temperatures <br />0.226 <br />Is the difference less than 10° F? If not, proceed to section 9.1 <br />Yes <br />§9.1 <br />T5 temperature <br />Calibrated thermometer ambient temperature <br />Difference between T5 and calibrated thermometer <br />Is the difference less than 10° F? If not, the T5 thermometer does not meet specifications <br />UST 92 <br />§7.3.3 <br />T5 temperature <br />82.228 <br />T4 temperature <br />81.571 <br />Difference between T5 and T4 temperatures <br />0.657 <br />Is the difference less than 10° F? If not, proceed to section 9.1 <br />Yes <br />§9.1 <br />T5 temperature <br />Calibrated thermometer ambient temperature <br />Difference between T5 and calibrated thermometer <br />Is the difference less than 10° F? If not, the T5 thermometer does not meet specifications <br />on ana ae[aeJJormea <br />after reasonable inquiry, the statements and information provided in this document are true, accurate, and complete. <br />Signature of Technician: Date: 9/6/18 <br />Ver. 1.1 —01,20,09 <br />