My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2185
>
2300 - Underground Storage Tank Program
>
PR0231118
>
COMPLIANCE INFO 2009 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2023 2:30:31 PM
Creation date
10/21/2019 2:23:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2018
RECORD_ID
PR0231118
PE
2371
FACILITY_ID
FA0003284
FACILITY_NAME
FOOD MART GASOLINE*
STREET_NUMBER
2185
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
14113045
CURRENT_STATUS
01
SITE_LOCATION
2185 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
41 <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:wvwv.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> FOOD MART GASOLINE` (209)547-1700 September 29,2017 <br /> Facility Address: CERS ID: <br /> 2185 E FREMONT ST, STOCKTON, CA 95205 10181081 <br /> Inspection Contact: Title: Phone: <br /> Devon Loomba Manager (408)839-8115 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 2371 -UST FACILITY-1702 COMPLIANT <br /> Consent For: Consent Given By: <br /> Z Inspection 2 Photos O Sample Devon Loomba, Manager <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Felix Ramirez 11/22/2018 David Winkler 02/26/2018 <br /> Service Technician Manufacturer's Training: <br /> Tank Tester, 05/31/20;Veeder Root,07/06/18;VMI, 11/05/17 <br /> CCR=California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284 No permit to operate ❑V ❑R ❑COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system ❑V o R o COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted o V o R o COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current o V o R o COS <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan o V o R o COS <br /> 106 CCR 2632(d)(2) Failed to have an approved UST response plan o V o R o COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed o V o R o COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing o V o R o COS <br /> 109 CCR 2637 Failed to test secondary containment o V o R o COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days o V o R o COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually o V o R ❑COS <br /> 112 HSC 25284.2 Failed to test spill containers annually ❑V o R o COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days o V o R o COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down o V o R ❑COS <br /> 115 CCR 2715(a) Failed to inform the EHD of designated operator identification or change within 30 days o V o R o COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification o V o R o COS <br /> 117 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after o V o R o COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests o V o R o COS <br /> 119 HSC 25299 Documents were falsified or misrepresented o V o R ❑COS <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification o V o R o COS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report o V o R ❑COS <br /> 122 CCR 26310) Failure to submit UST system component statement of compatibility for substance stored o V ❑R ❑COS <br /> On Site Records <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions ■V o R ❑COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years o V o R o COS <br /> 203 CCR 2712(b) Failed to maintain records of monitoring,repair,lining,and upgrades on site o V o R o COS <br /> FA0003284 PRO231118 SCO01 09/29/2017 <br /> EHD 23-01 Rev.09/22/16 Page 1 of 3 Underground Storage Tank Program OIR <br /> 9171 9690 0935 0151 6820 91 <br />
The URL can be used to link to this page
Your browser does not support the video tag.