My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2185
>
2300 - Underground Storage Tank Program
>
PR0231118
>
COMPLIANCE INFO 2009 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2023 2:30:31 PM
Creation date
10/21/2019 2:23:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2018
RECORD_ID
PR0231118
PE
2371
FACILITY_ID
FA0003284
FACILITY_NAME
FOOD MART GASOLINE*
STREET_NUMBER
2185
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
14113045
CURRENT_STATUS
01
SITE_LOCATION
2185 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
416 2"" Street <br />Galt, CA 95632 <br />(209) 744-0113 Fax (209) 744-0116 <br />E.O. VR -203/204 <br />Vapor Pressure Sensor Verification Test & VST Processor Activation Pressure <br />Test Report Form <br />Permit Number: N-4721-14 <br />CONF # 18-25877 <br />Test Company: AFFORDA TEST <br />416 2ND STREET GALT, CA 95632 <br />209-744-0113 FAX 209-744-0113 <br />Site Name: FOOD <br />MART GAS <br />Technician: Zane A. Nimmo <br />Site Address: 2185 <br />E. FREMONT STREET <br />Certification Number / Expiration Date <br />City: STOCKTON <br />Zip: 95205 <br />District: S J V A P C D <br />Date/Time of Test: <br />9/6/2018 <br />VST: 3000839502 <br />Veeder-Root: Zane A. Nimmo #A28446 <br />TEST INFORMATION <br />Pressure sensor located at dispenser number(s) <br />VENT STACK <br />Pressure sensor serial number <br />1 2 8 06 <br />Calibration date for digital manometer (must be within 12 months of the test) <br />7/13/2018 <br />Ending value for digital manometer drift test (must be 0.01 in. w.c. or less) <br />.00 <br />VAPOR PRESSURE SENSOR UST PRESSURE TEST <br />UST pressure from digital manometer (in. w.c.) <br />3.31 <br />Pressure sensor value from TLS -350 (in. w.c.) <br />3.345 <br />Is Pressure Value Between -0.20 and +0.20 in. w.c.? <br />YES <br />VAPOR PRESSURE SENSOR AMBIENT REFERENCE TEST1,2 <br />Non -calibrated pressure sensor value from TLS -350 (in. w.c.) 0.037 <br />Is pressure value between -0.20 and +0.20 in. w.c.? YES <br />VST PROCESSOR ACTIVATION PRESSURE TESTf,a <br />VST processor activation pressure (in. w.c.) <br />Is the VST processor activation pressure _< 0.4 in. w.c.? N / A <br />NOTES: 'Valve must be returned to normal operating position after testing is comp>ietea. <br />ZThe ambient reference port cap must be in place after testing is completed. <br />I declare, under penalty <br />of perjury under the laws of the state of California that based on information and belief formed <br />after reasonable inquiry, the statements and information provided in this document are true, accurate, and complete. <br />Signature of Technician: ej Date: 9/6/2018 <br />
The URL can be used to link to this page
Your browser does not support the video tag.