Laserfiche WebLink
SYSTEM CONSTRUCTION SYSTEM MAINTENANCE 0 <br /> eq 8 <br /> 1. THE SEPTIC SYSTEM COMPONENTS AND INSTALLATION SHOULD BE ACCORDING 1. THE SEPTIC TANK IS REQUIRED TO BE PUMPED AND CLEANED A MINIMUM OF Uj w <br /> TO SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH SEWAGE STANDARDS, EVERY THREE (3) YEARS.ACCESS TO THE SEPTIC SYSTEM DISPOSAL FIELD BY z W <br /> 2. THE SIDES AND BOTTOM OF ALL LEACH LINE TRENCHES AND THE SIDES(OF THE SERVICE EQUIPMENT SHOULD BE MAINTAINED. � a } 0 ° <br /> U O 0 Z O p <br /> DRY WELLS SHOULD BE RAKED OR SCARIFIED PRIOR TO THE PLACEMENT OF 2. ASEPTIC SYSTEM OPERATES BY UTILIZING MICRO ORGANISMS TO CONSUME <br /> U F <br /> GRAVEL TO ELIMINATE AN SOIL "SMEARING" THAT MAY HAVE OCCURRED DURING <br /> EXCAVATION, SINCE THIS IS CRITICAL.., ALL TRENCH AND DRY WELL EXCAVATIONS WASTE PRODUCTS. HOUSEHOLD CHEMICALS, PAINTS, OR MINERAL SALT FROM A � � � z g O O <br /> SHOULD BE INSPECTED BY A REPRESENTATIVE OF NEIL O.ANDERSON 8( ASSOC. WATER SOFTENER SHOULD BE KEPT OUT OF THE SEWER/SEPTIC SYSTEM AS <br /> PRIOR TO THE PLACEMENT OF ANY GRAVEL. THESE SUBSTANCES ARE HARMFUL TO THE NECESSARY ORGANISMS. <br /> 3. FINAL GRADING OF THE SURF=ACE OF THE DISPOSAL FIELDS SHOULD BE SUCH <br /> 3. POSITIVE DRAINAGE AWAY FROM THE DISPOSAL FIELDS SHOULD BE MAINTAINED Z +� O OI— O <br /> AT ALL TIMES. <br /> THAT DRAINAGE WATER IS NOT ALLOWED TO COLLECT OR POND OVER TIHE LU z V <br /> oFIELDS. o U <br /> � <br /> 4. NO PERMANENT STRUCTURES OR HARD SURFACES(I.E. CONCRETE FLAT'WORK, (� Q U <br /> ASPHALT PAVING, ETC.) SHOULD BE CONSTRUCTED OVER THE LEACH FIELDS. 1.= <br /> 5. THE ONLY LANDSCAPING PERMITTED OVER THE INSTALLED LEACH FIELDS IS W <br /> GRASS OR LOW SHRUBS. A MINIMUM SEPARATION OF 10 FEET SHOULD BE Q U <br /> MAINTAINED BETWEEN THE LEACH FIELDS AND PLANTED TREES OR DEEP' <br /> ROOTED SHRUBS, SAN JOAQUIN COUNTY Z 0 <br /> 6. THE DESIGNATED REPLACEMENT AREA SHOULD BE KEPT FREE OF ANY WINIRONMENTALNMTHDEPAWMW cn o <br /> PERMANENT STRUCTURES (I.E. SWIMMING POOLS). N4I1 I RAVETHWft 0R w � o <br /> CA Q o` c i co <br /> o ¢ LL __j 00 <br /> PROPOWA �Wilt O < f <br /> n. QdTANNIII11III'[AT01u.l O 6: ro <br /> ❑ I- u_ o Cl) <br /> �, S :J C14 <br /> CCS t D 10NdMDh'ED BELOW ;L Z O Z " z <br /> _ � <br /> R O p OT <br /> Q U Or, .J a- LL <br /> a Dft By <br /> RESIDENCE& O RESILIENCE18 ftM and <br /> ed <br /> fie <br /> FALLOW LAND W)& hemo�n VW not Outhodze��pme piny Omission bor <br /> ORCHARD deviation from requirements of state laws or focal ordinances. <br /> z <br /> TRETHWAY ROAD <br /> EXISTING WELL EXISTING WELL ">> <br /> 100'-0" 150'-0" TYPICAL WELT- <br /> TYPICAL WELL <br /> � 100'-0" 150'-0" / <br /> 100'-0" 150"-0" <br /> --' <br /> SAN J 1�f <br /> OAQUIN COUNTY � <br /> RESIDENCE (EXACT SIZE& RESIDENCE (EXACT SIZE� �� RESIDENCE (EXACT SIZE s, ENVIRONMENTAL HEALTH DEPARTMENT z <br /> LOCATION UNDETERMINED) i <br /> LOT I LOT ' r LOCATION UNDETERMll;E._, LOCATION UNDETERMINED) W Q 0 Q <br /> J <br /> LM <br /> � 'i'!1 �`,�.: .. .: Sewer pipe shall be no deeper than 3a" W O <br /> _ �r N N <br /> AF'PE':"JX. 5 ACRES APPROX. ��',�1�FS � d" <br /> I I �t I below finish grade, A depth greater H <br /> ❑ ❑ than 18"will require an approved N <br /> lift station. Maximum depth pt leach <br /> RESIDENCE& ENGINEERING SEPTIC SYSTEM ENGINEERING SEPTIC SYSTEM J .���JJJ line is 42". Maximum soil cover over V ( �1 � = Q <br /> ENGINEERING SEPTIC SYSTEM — sEwarlt uNE chamber e systems is 2 " V V <br /> FALLOW LAND NOT REQUIRED NOT REQUIRED SEPTIC TANK LOT 3 NOT REQUIRED SEPTICTANK — s SEI�TIC TANK 4 <br /> D (SEE SHEET G2 APPROX. 5 ACRES LOT '� hp vs 4 ' ~ Q V 0 " <br /> O FOR DETAILS) (SEE SHEET G2 I OT goal t t 0 �"' V ag G <br /> Q (SEESI-]EFT O APPROX. S ACRES FOR DETAILS) AI'PROX. _a �, -:.,, 18" 0 a <br /> p� FC)I DETAILS' fA <br /> QSEPTIC TANK z G W <br /> RESIDENCE& �ii p� M V <br /> � I <br /> FALLOW L/AND 0 z ■ N Q <br /> PRIMARY AREA <br /> PRIMARYAREA � PRIMARYAREA, <br /> I m RESERVE AREA RESERVE ARF/.\ RESERVE AREA <br /> ���• '�. _� �" <br /> 150` 0" *SDUPRIMARY ARE—k <br /> �DU RESERVE AREA -- <br /> .. <br /> � .. <br /> F <br /> 'SDU RESERIZVE <br /> AREA <br /> 100'-01, I <br /> �..._._.. .. ._-.__ - .,.SD'J PRIMARY <br /> r r yC�IJ f�RfMAFRY <br /> AREA Q <br /> `SF-GOND DWELLING UNIT(SDU) `SECOND DWELLING UNIT (SDU) A "SECOND DWELLING UNIT(SDU) <br /> z <br /> o <br /> SECONDARY DWELLING UNITS (SDU)ARE NOT PLANNED AS PART OF THIS OR ANY FUTURE PROJECT. THE 0 <br /> ENVIRONMENTAL HEALTH DEPARTMENT REQUIRES SDU SEPTIC SYSTEM LAYOUTS AS PART OF THE SITE APPROVAL. a, <br /> V <br /> Ln <br /> Lu <br /> i <br /> LUIsl <br /> Q <br /> t� <br /> O � co U <br /> GENERAL SEPTIC SYSTEM LAYOUT; APN: 007-380-11 ; LOT #3 tri <br /> SCALE: 1"=100'-o" <br /> Q�pFE53/a� % <br /> A <br /> xp. 7 <br /> *lglF OFICAtkFO��\�>k <br /> JOB NUMBER <br /> t" Eos> >6B <br /> SCALE: <br /> fAS NOTED <br /> 0 100' 200' 300' DATE: <br /> • <br /> 2/2/05 <br /> NOTES: APPROXIMATE SCALE:1"=100'-0" DRAWN BY: <br /> J. KAMENICKY <br /> 1. NAL LOCATION OF RESIDENCE AND SEPTIC SYSTEM TO BE DETERMINED BY PROPERTY OWNER. <br /> DESIGNED BY: <br /> 2. BASE MAP PROVIDED BY: COUNTY OF SAN JOAQUIN, CALIFORNIA, ASSESSORS MAP BK. 007, PG38 NOTES: <br /> D. WELCH <br /> 1)PLAN NOT VALID WITHOUT ORIGINAL ENGINEERING STAMP AND SIGNATURE. SHEET <br /> 2)PLAN ONLY TO BE USED FOR THE RESIDENCE AND LOT SPECIFIED IN TITLE BLOCK. <br /> Copyright 02005 Neil Anderson-All Rights Reserved-This document was prepared for use only by the client, only for the purposes stated, and within a reasonable time from issuance. Non-commercial, educational, and scientific use of this report by regulatory agencies is regarded as a"fair use"and not a violation of copyright. Regulatory agencies may make additional copies of this document for internal use. Copies may also be rade available to theG I <br /> public as required by law. The reprint must acknowledge the copyright and indicate that permission to reprint has been received. <br /> i <br /> i <br />