4 <br /> KEY TO RESULT FLAGS <br /> RPD between sample duplicates exceeds 309., <br /> *� RPD between sample duplicates or MS/MSD exceeds Zoe <br /> Correlation coefficient for the Method of Standard Additions is less than 0 995 <br /> Sample result is less than reported value <br /> -I Value is between Method Detection Limit and Reporting Limit <br /> B-0 Analyte found in blank and sample <br /> The result confirmed by secondary column or GC/MS analysis <br /> NA Cr+6 not analyzed, Total Chromium concentration below Cr+6 regulatory level <br /> COMP Sample composited by equal volume prior to analysis <br /> CV 2-Chloroethylvinyl ether cannot be determined in a preserved sample. <br /> WT Due to the sample matrix, constant weight could not be achieved <br /> The result has an atypical pattern for Diesel analysis. <br /> D1 The result for Diesel is an unknown hydrocarbon which consists of a single peak <br /> ND for hydrocarbons, non-discrete baseline rise detected <br /> j-18, The result appears to be a heavier hydrocarbon than Diesel <br /> L The result appears to be a lighter hydrocarbon than Diesel <br /> DR Elevated Reporting Limit due to Matrix <br /> S Surrogate diluted out of range <br /> X The result for Diesel is an unknown hydrocarbon which consists of several peaks <br /> A Compound quantitated at a 2X dilution factor <br /> FB Compound quantitated at a 5X dilution factor <br /> 'FC Compound quantitated at a lOX dilution factor <br /> FD Compound quantitated at a 20X dilution factor <br /> FE Compound quantitated at a 50X dilution factor <br /> FF Compound quantitated at a 100X dilution factor <br /> 'FG Compound quantitated at a 20OX dilution factor <br /> FH Compound quantitated at a 50DX dilution factor <br /> FI Compound quantitated at a 1000X dilution factor <br /> Compound quantitated at a greater than 1000x dilution factor <br /> Compound quantitated at a 25X dilution factor <br /> I*F Compound quantitated at a 25OX dilution factor <br /> G- The result has an atypical pattern for Gasoline <br /> ,G1 The result for Gasoline is an unknown single peak <br /> GH The result appears to be a heavier hyarocarbon than Gasoline <br /> GL The result appears to be a lighter hydrocarbon than Gasoline <br /> GX The result for Gasoline is an unknown hydrocarbon which consists of several peaks <br /> 'HT Analysis performed outside of the method specified holding time <br /> HTC Confirmation analyzed outside of the method specified holding time <br /> HTP Prep procedure performed outside of the method specified holding time <br /> HTR Received after holding time expired, analyzed ASAP after receipt <br /> I <br /> HX Peaks detected within the quantitation range do not match standard used <br /> J Value is estimated <br /> MI Matrix Interference Suspected <br /> IMSA Value determined by Method of Standard Additions <br /> MSA* Value obtained by Method of standard Additions, Correlation coefficient is <0 995 <br /> NI1 Sample spikes outside of QC limits, matrix interference suspected <br /> NI2 Sample concentration is greater than 4X the spiked value, the spiked value is <br /> considered insignificant <br /> 'NI3 Matrix Spike values exceed established QC limits, post digestion spike is in <br /> control <br /> NI4 MS/MSD outside of control limits, serial dilution within control <br /> ' P There is >40o difference between primary and confirmation analysis <br /> P7 pH of sample > 2, sample analyzed past 7 days <br /> RSC Refer to subcontract laboratory report for QC data <br /> S2 Matrix interference confirmed by repeat analysis <br /> ' SCN Thiocyanate not analyzed separately, total value is below the Reporting Limit for <br /> Free Cyanide <br /> Analysis performed by Selective Ion Monitoring <br /> Conc of the total analyte ND, therefore this analyte is ND also <br /> UMDL Undetected at the Method Detection Limit <br /> UTD Unable to perform requested analysis <br /> FORM FLAGS rev 04/08/1997 <br />