Laserfiche WebLink
Percolation Test <br /> Shallow percolation tests were conducted in the proposed septic disposal area and 100 <br /> percent replacement area of the Site. The soil borings discussed above were used for <br /> the percolation test holes (Plate 10). Percolation test procedures conformed to San <br /> Joaquin County Environmental Health Department policy. <br /> Preparation and Presaturation of Percolation Test Holes <br /> After the borings were advanced by hand auger and the soils logged, the test holes <br /> were completed for the percolation tests. Approximately two inches of pea gravel were <br /> placed in the bottom of each open soil boring, followed by a 2.0-inch diameter PVC pipe <br /> with perforations on the bottom. Pea gravel was then used to backfill a few inches of <br /> the annular space. <br /> Live Oak presaturated each percolation test hole approximately 24 hours prior to the <br /> percolation testing. The holes were filled with water to a height of 12 inches above the <br /> bottom of the borings for the presaturation. On the day of testing, both holes were <br /> found to be intact and dry. <br /> Percolation Test Procedure <br /> Live Oak conducted the percolation tests for the borings on December 13, 2018. Due to <br /> initial percolation rates observed, one-hour tests were selected. Water level . <br /> measurements were taken every ten minutes during this one-hour period. The last ten <br /> minutes of the test were observed by Sukhreet Kaur, Registered Environmental Health <br /> Specialist at the San Joaquin County Environmental Health Department. <br /> An electronic well sounder with a depth accuracy of 1/100th foot was utilized for the <br /> water level measurements. The water level was measured against a fixed reference <br /> point on the well casing. Measurements were recorded on the data sheet in decimal <br /> feet. When necessary after measuring the water level, the hole was refilled with water <br /> to a level of six inches or more above the bottom of the hole. <br /> Percolation Test Results <br /> The completed percolation test form is included in Appendix 2 of this report. The form <br /> was signed by Ms. Kaur and indicates a percolation rate for each hole based on the <br /> final water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is greater than or equal to 1 minute per inch (min/in) but less than <br /> or equal to 60 min/in drop. For the Site to utilize a standard septic system, one <br /> LOGE 1846 Page 5 <br />