Percolation Test Results <br /> The completed percolation test form is included in Appendix 3 of this report. The form <br /> was signed by Ms. Kaur and indicates a percolation rate for the hole based on the final <br /> water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is greater than or equal to 1 minute per inch (min/in) but less than <br /> or equal to 60 min/in drop. For the Site to utilize a standard septic system, one <br /> percolation test must demonstrate a satisfactory percolation rate within the proposed <br /> septic system disposal field. Details and results of the percolation test are summarized <br /> in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> P1, <br /> 7/23/2019 3.18 4.46 4 hr. Satisfactor�r perc. <br /> rate <br /> Shallow Test <br /> Note: A satisfactory percolation rate for a "shallow' test is greater than 1 but less than or equal to 60 minutes per <br /> inch. <br /> 1 Per San Joaquin County Environmental Health Department, a rate between 1.0 and 5.0 min/in requires a <br /> 20-foot separation between the bottom of dispersal system and ground water, or mitigation by system <br /> design or enhancement. <br /> Discussion of Percolation Test Results <br /> The soils within the proposed sewage disposal area of the Site have demonstrated a <br /> satisfactory percolation rate for the use of a standard septic system in accordance with <br /> the requirements of the San Joaquin County Environmental Health Department. <br /> Because of the percolation rate between 1.0 and 5.0 min/in encountered in the test <br /> hole, the San Joaquin County Environmental Health Department will require a 20-foot <br /> separation from the bottom of the dispersal system to ground water (see Table 2). <br /> Ground water is anticipated to be encountered approximately 28 to 45 feet below <br /> ground surface at the Site; consequently, no modifications to standard, shallow septic <br /> systems should be required. <br /> Discussion of Septic System Sizing <br /> Septic system construction utilizing leach lines or a filter bed should follow the San <br /> Joaquin County On-Site Wastewater Treatment Systems Standards (2017) where <br /> applicable. <br /> LOGE 1936 Page 6 <br />