SR0080832
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
6819
>
2600 - Land Use Program
>
SR0080832
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2019 3:10:02 PM
Creation date
11/8/2019 1:56:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SR0080832
PE
2602
FACILITY_NAME
WINTERS PROPERTY
STREET_NUMBER
6819
Direction
E
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19714009
ENTERED_DATE
6/28/2019 12:00:00 AM
SITE_LOCATION
6819 E LATHROP RD
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Percolation Test Results <br /> The completed percolation test form is included in Appendix 3 of this report. The form <br /> was signed by Ms. Kaur and indicates a percolation rate for the hole based on the final <br /> water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is greater than or equal to 1 minute per inch (min/in) but less than <br /> or equal to 60 min/in drop. For the Site to utilize a standard septic system, one <br /> percolation test must demonstrate a satisfactory percolation rate within the proposed <br /> septic system disposal field. Details and results of the percolation test are summarized <br /> in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> 6/18/2019 3.29 15.62 4 hr. Satisfactor;y perc. <br /> rate <br /> Shallow Test <br /> Note: A satisfactory percolation rate for a "'shallow" test is greater than 1 but less than or equal to 60 minutes per <br /> inch. <br /> 1 Per San Joaquin County Environmental Health Department, a rate between 5.0 and 30 min/in requires an <br /> eight-foot separation between the bottom of dispersal system and ground water, or mitigation by system <br /> design or enhancement. <br /> Discussion of Percolation Test Results <br /> The soils within the proposed sewage disposal area of the Site have demonstrated a <br /> satisfactory percolation rate for the use of a septic system in accordance with the <br /> requirements of the San Joaquin County Environmental Health Department. <br /> Because of the percolation rate between 5.0 and 30 min/in encountered in the test hole, <br /> the San Joaquin County Environmental Health Department will require an eight-foot <br /> separation from the bottom of the dispersal system to ground water, or mitigation by <br /> system design or enhancement (see Table 2). Ground water is anticipated to be <br /> encountered approximately 37 to 45 feet below ground surface at the Site; as a result, <br /> no modification to standard shallow septic systems should be required. <br /> Discussion of Septic System Sizing <br /> Septic system construction should follow the San Joaquin County On-Site Wastewater <br /> Treatment Systems Standards (2017) where applicable. Because of the elevated <br /> nitrate level detected in the irrigation well, it is recommended that a shallow septic <br /> system utilizing leach lines or a filter bed be installed. <br /> LOGE 1932 Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.