9.2 Provide form MF-1 R,"The 9.8 Show double glazing as per Energy <br /> Mandatory Energy Conservation Design on Glazing Schedule and <br /> Requirements"with items SHGC's. If Lo E,so note. <br /> appropriately checked. <br /> 9.9 The energy calculations stipulate <br /> 9.3 Show the size, type, make, and that a Radiant Barrier will be <br /> model of the space heating (or installed. The submitted plans do <br /> cooling) system and provide heat not specify this requirement <br /> loss and cooling load calculations. <br /> 9.10 The energy calculations stipulate <br /> 9.4 Show the size,type,make,model that diagnostic testing of the duct <br /> and energy factor of the water system by an approved HERS rater <br /> heater. is required. The submitted plans do <br /> not specify this requirement. <br /> 9.5 Unless an exempted model is <br /> specified, an R-12 external water 9.11 The energy calculations stipulate <br /> heater blanket shall be installed. that a split HVAC system(s)will be <br /> installed and a TXV is required to be <br /> 9.6 Show on the Title Sheet of the plans verified by an approved HERS rater. <br /> the required elements of the The plans submitted do not specify <br /> alternative energy package that was this requirement. <br /> selected, and next to each element <br /> show how you are complying with 9.12 The energy calculations stipulate <br /> each element. If calculations were that a hydronic heating system with <br /> used, provide similar data on the panels imbedded in concrete is to <br /> plans. be installed. Perimeter slab edge <br /> insulation is required with a value of <br /> 9.7 Show on the plans the"R value for R-10. The plans do not specify or <br /> the walls, floors, ceiling and related detail this requirement. <br /> areas. <br /> 19 <br />