My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0080902 SSCRPT
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
31411
>
2600 - Land Use Program
>
SR0080902 SSCRPT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2019 3:48:46 PM
Creation date
11/8/2019 3:30:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSCRPT
RECORD_ID
SR0080902
PE
2603
STREET_NUMBER
31411
Direction
S
STREET_NAME
KASSON
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
25534001
ENTERED_DATE
7/17/2019 12:00:00 AM
SITE_LOCATION
31411 S KASSON RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6.7 Provide a raised platform for any <br /> furnace, water heater or other 6.11 Note on plan: Gas vents and <br /> device in the garage which may noncombustible piping,in walls, <br /> develop a spark or flame so that the passing through three floors or less <br /> spark or flame will be at least 18" shall be effectively draft-stopped at <br /> above the garage floor. UMC, each floor or ceiling with <br /> Section 308.0. noncombustible material. UBC <br /> Section 711.3. <br /> 6.8 Show the source of combustion air <br /> to furnace in compliance with Where a water heater and furnace <br /> Chapter 7,Table No.7-1, UMC. The are shown side by side, indicate <br /> minimum free area of both the that they will be separately vented <br /> upper and lower combustion air or detail the combined vent <br /> openings when taken from inside or connector on the plans, sized in <br /> outside of building shall not be less accordance with the GAMA Venting <br /> than 100 square inch each and Tables. <br /> located within 12" of floor and <br /> ceiling,with a maximum input rating 6.13 Provide dryer vent to exterior. <br /> of 100,000 BTU/HR. Unless otherwise permitted or <br /> required by the dryer <br /> 6.9 When all combustion air is taken manufacturers installation <br /> from the outdoors one opening is instructions and approved by the <br /> permitted. The opening shall equal building official,domestic dryer <br /> 1 sq.in.per 3,000 BTU/HR input,but moisture exhaust ducts shall not <br /> no smaller than vent flow area. exceed a total combined horizontal <br /> and vertical length of 14 feet(4267 <br /> 6.10 Furnace shall not be installed in any mm),including two 90-degree <br /> bedroom,bathroom or In a closet or elbows. Two feet(610 mm)shall be <br /> confined space with access only deducted for each 90-degree elbow <br /> through such room, unless in excess of two. UMC,Section <br /> specified as direct vent appliance, 504.3.1. <br /> enclosed furnace or electric heating <br /> appliance. UMC,Section 904.5. <br /> 14 <br />
The URL can be used to link to this page
Your browser does not support the video tag.