My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0080902 SSCRPT
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
31411
>
2600 - Land Use Program
>
SR0080902 SSCRPT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2019 3:48:46 PM
Creation date
11/8/2019 3:30:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSCRPT
RECORD_ID
SR0080902
PE
2603
STREET_NUMBER
31411
Direction
S
STREET_NAME
KASSON
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
25534001
ENTERED_DATE
7/17/2019 12:00:00 AM
SITE_LOCATION
31411 S KASSON RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5.32 Braced wall panels shall be spaced 5.39 Show stud size and spacing. <br /> every 25 feet in interior and exterior Maximum allowable stud heights; <br /> braced wall lines and as required by bearing wall: 2 x 4 and 2 x 6 <br /> UBC Table 23-1V-C-1 for multi-story maximum 10 foot, non-bearing: 2 x <br /> buildings. 4 maximum 14 foot,2 x 6 maximum <br /> 20 feet. UBC Section 2320.11.1 and <br /> 5.33 If method 5 is used for a braced wall Table 23-IV-B. <br /> panel, nail gypsum board at 7" on <br /> center with nails as required by 5.40 Specify all header sizes for <br /> UBC Table 25.1. openings over 4 feet wide. UBC <br /> Section 2320.11.6. <br /> 5.34 Provide an alternate wall panel not <br /> less than 2'-8" wide in accordance 5.41 Specify floor and roof plywood <br /> with Section 2320.11.4 where a 48 grade and panel identification Index. <br /> inch wide wall is not available. UBC Table 23-11-E-1. <br /> 5.42 When roof slope is less than 3:12, <br /> 5.35 The top plate of interior braced wall members supporting rafters and <br /> lines shall be attached to the top ceiling joists such as ridge board, <br /> plate of the intersecting exterior wall hips and valleys shall be designed <br /> by use of a coil strap or equal. as beams. UBC Section 2320.12.1 <br /> 5.36 Let-in bracing is not allowed in 5.43 Show or note fire blocks and draft <br /> Seismic Zones 3 and 4 as required stops at the following locations per <br /> bracing. UBC Section 708. <br /> 5.37 Show double top plate with a. In concealed spaces in stud walls <br /> minimum 48" lap splice and nailed and partitions at the ceiling and <br /> at each end with four 16d nails. floor levels and at 10 ft. intervals <br /> UBC Section 2320.11.2. both horizontal and vertical. <br /> b. At all interconnections between <br /> 5.38 Show nailing schedule on plans in concealed vertical and horizontal <br /> compliance with UBC Table 23-11-B- spaces such as occur at soffits, <br /> 1. drop ceilings and cove ceilings. <br /> I <br /> 12 <br />