My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0080902 SSCRPT
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
31411
>
2600 - Land Use Program
>
SR0080902 SSCRPT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2019 3:48:46 PM
Creation date
11/8/2019 3:30:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSCRPT
RECORD_ID
SR0080902
PE
2603
STREET_NUMBER
31411
Direction
S
STREET_NAME
KASSON
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
25534001
ENTERED_DATE
7/17/2019 12:00:00 AM
SITE_LOCATION
31411 S KASSON RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Garage requires one-hour fire 3.20 Doors may open into the garage <br /> protection on the garage side of only if the floor or landing in the <br /> walls and ceiling common to the garage is not more than 1" lower <br /> dwelling. Walls supporting ceilings than the door threshold, or if door <br /> require equivalent fire protection. opens into house, the landing, step <br /> UBC Table 76, Section 302.4. Q or floor difference shall not exceed <br /> L U.j���0 � ����� ��� `®� 811. UBC Section 1003.3.1.6. <br /> 3.16 Indicate that firewall extends from <br /> garage floor to roof sheathing or 3.21 Indicate a 36" minimum depth <br /> may terminate at garage ceiling if landing outside of exterior doors. <br /> the entire ceiling is finished with UBC Section 1003.3.1.7 <br /> a 1-Hr system. Detail attachment in <br /> accordance with UBC Table 7-C. If 4. FOUNDATION PLAN <br /> supporting structure is at 24" o.c., <br /> use two layers of 5/8"type-x 4.1 The proposed project is located <br /> gypsum board or one layer over within an expansive soil area where <br /> resilient channel at 24"o.c.or 2" a conventional foundation may not <br /> wood furring at 16"o.c. be suitable. Therefore, an engineer <br /> or an architect is required to re- <br /> 3.17 Show 1-3/8" solid core self-closing evaluate the foundation design or <br /> door or 20 minute door for openings specify all footings to be 18" deep. <br /> between garage and dwelling. UBC UBC Section 1804.4. <br /> Section 302.4. <br /> 4.2 The proposed project is located in a <br /> 3.18 All elements supporting floor above subsidence area where a <br /> garage, including walls supporting conventional foundation may not be <br /> floor joists, shall have one-hour, suitable. Therefore, a complete <br /> fire-resistive protection on the soils report by a geotechnical <br /> garage side. UBC Section 302.4. engineer and foundation design are <br /> required. UBC Section 1804. <br /> 3.19 Garages are not permitted to open <br /> into a room used for sleeping <br /> purposes. UBC Section 312.4. <br /> -76 'L'0 0o 8� <br /> 6 <br /> it <br />
The URL can be used to link to this page
Your browser does not support the video tag.