Laserfiche WebLink
I <br /> 1203.2. <br /> 3. FLOOR PLAN 3.7 Openable window and openable <br /> skylight area in habitable rooms <br /> 3.1 Provide a copy of a complete floor must be 1/20 of the floor area and a <br /> plan to be given to the County minimum of 5 square feet. In <br /> Assessor. bathrooms and similar rooms, 1/20 <br /> of area is required and the minimum <br /> 3.2 Identify all rooms as to use. Show is 1.5 square feet. UBC Section <br /> dimensions of all rooms. 1203.3. <br /> 3.3 Indicate window sizes and their 3.8 At least 1/2 of the common wall <br /> method of opening on floor plan. must be open and have an opening <br /> not less than 1/10 of the floor area <br /> 3.4 Provide floor plan of rooms of the interior room or 25 square <br /> adjoining proposed addition. feet whichever is greater if light and <br /> Indicate any windows and doors, ventilation is being supplied from <br /> including their sizes and method of adjacent room. UBC Section 1203.1. <br /> opening, which are affected by the <br /> addition. 3.9 Required windows shall not open <br /> into a roofed porch unless the <br /> 3.5 Dwelling units and congregate ceiling is at least 7 feet and the <br /> residences shall have at least one longer side is at least 65% open. <br /> room which shall have not less than UBC Section <br /> 120 sq.ft. of floor area. Habitable 1203.1. <br /> rooms, other than kitchens shall <br /> contain at least 70 square feet of <br /> floor area with no dimension less <br /> than 7 feet.UBC Section 310.6.2&3. <br /> Window and skylight area must be <br /> at least 1110 of the floor area with a <br /> minimum of 10 square feet in all <br /> habitable rooms. UBC Section <br /> A� F�� <br /> 4 <br /> I <br />