My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0000119 SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FLOOD
>
21409
>
2600 - Land Use Program
>
MS-98-30
>
SU0000119 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2019 2:32:16 PM
Creation date
11/14/2019 2:17:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0000119
PE
2622
FACILITY_NAME
MS-98-30
STREET_NUMBER
21409
Direction
E
STREET_NAME
FLOOD
STREET_TYPE
RD
City
LINDEN
ENTERED_DATE
8/8/2001 12:00:00 AM
SITE_LOCATION
21409 E FLOOD RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PERCOLATION TEST RESULTS: <br /> ON JUNE 18, 1999, PARCELS 1 AND 2 WERE TESTED TO DETERMINE THE <br /> PERCOLATION RATE. MR. TREVENA FROM THE SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT OBSERVED THE READINGS FROM 11:00 <br /> AM TO 11:30 AM. THE LAST READINGS WERE TAKEN BETWEEN 11:30AM AND 12:00 <br /> PM. TWO TEST HOLES WERE DUG FOR EACH PARCEL. TEST HOLE 2A FAILED; <br /> HOWEVER TEST HOLE 2B PASSED. IT IS MY OPINION THAT TEST 2A WOULD HAVE <br /> PASSED IF WE REFILLED THE HOLE WITH MORE WATER AFTER THE WATER <br /> PERCOLATED. PARCELS 1 AND 2 PASSED THE PERCOLATION TEST WITH A <br /> PERCOLATION RATE OF 21 MIN/INCH FOR A DEPTH OF 3 FEET AND 60 MIN/INCH <br /> FOR A DEPTH OF 3 FEET, RESPECTIVELY. PERCOLATION TESTS WERE <br /> CONDUCTED IN ACCORDANCE WITH SAN JOAQUIN COUNTY ENVIRONMENTAL <br /> HEALTH DEPARTMENT REQUIREMENTS. <br /> COMMENTS REGARDING EXISTING SEPTIC SYSTEMS: <br /> BASED ON THE INFORMATION GIVEN ON SHEET 5, THE EXISTING SEPTIC <br /> SYSTEMS IN THE AREA ARE FUNCTIONING WITH NO PROBLEMS. THE EXISTING <br /> SEPTIC SYSTEMS IN THE AREA CONSIST OF A SEPTIC TANK AND LEACH LINES <br /> WITH A SEEPAGE PIT OR PITS WITH A DEPTH OF 25 FEET WITH A DIAMETER OF NO <br /> LESS THAN 33 INCHES. <br /> ENGINEER'S OPINION SOIL SUITABILITY: <br /> FROM THE RESULTS OBTAINED FROM THE PERCOLATION TESTS AND EXISTING <br /> PERMITS FOR THE REPAIR AND INSTALLATION OF PRIVATE DISPOSAL SYSTEMS, <br /> THE SEPTIC SYSTEMS FOR PARCELS 1 AND 2 SHOULD CONSIST OF A 12, 000 <br /> SQUARE FOOT LEACH FIELD AREA AND SEEPAGE PITS. THE SEEPAGE PITS <br /> SHOULD HAVE A MINIMUM DIAMETER OF 33 INCHES AND SHALL NOT BE <br /> INSTALLED TO A DEPTH OF GREATER THAN 25 FEET. THE NUMBER OF SEEPAGE <br /> PITS AND LENGTH OF LEACH LINES SHALL BE DESIGNED FOR THE SOIL <br /> CONDITIONS IN THE AREA, AND THE SIZE OF THE HOUSE OR FACILITY TO BE <br /> SERVED. <br /> THE GROUNDWATER TABLE IS LOCATED APPROXIMATELY 125 FEET BELOW THE <br /> GROUND SURFACE. THEREFORE, THE GROUNDWATER LEVEL WILL MEET THE <br /> TEN FOOT MINIMUM DISTANCE BETWEEN THE BOTTOM OF THE SEEPAGE PITS <br /> AND THE TOP OF THE GROUNDWATER TABLE. THE SEPTIC SYSTEM SHOULD NOT <br /> ADVERSELY AFFECT THE GROUND WATER TABLE. <br /> IT IS OUR PROFESSIONAL OPINION THAT THE FINDINGS INCLUDED IN THIS STUDY <br /> ARE A REPRESENTATIVE ASSESSMENT OF THE PROJECT AREA AT THE PRESENT <br /> TIME. THIS OPINION CANNOT CONSTITUTE A GUARANTEE OR WARRANTY, <br /> EITHER EXPRESSED OR IMPLIED. <br /> WATER TEST RESULTS: <br /> ENCLOSED ON THE FOLLOWING PAGES IS THE TEST RESULTS FOR THE EXISTING <br /> WELL BY FGL ENVIRONMENTAL. <br /> SHEET 6 <br />
The URL can be used to link to this page