� � O <br /> d � o <br /> � o <br /> SEEPAGE PIT <br /> O <br /> DESIGN DATA <br /> FILTER FABRfC OR UNTREATED NATIVE GRADE FILTER FABRIC OR UNTREATED n <br /> BUILDING PAPER BUILDING PAPER NATIVE SOIL BACKFILL TO BE FILTER FABRIC OR UNTREATED v <br /> CAPA 18" DEE'" (MIN.) BUILDING PAPER GENERAL DESIGN DATA: \ <br /> DISTRIBUTION PIPE n ' O V <br /> rr Application: 5 bedroom single family dwelling ■�/ �n <br /> __.. <br /> —L --------- Water supply: Community water supply ` V � <br /> — — / Septic tank: 2000 gallon septic tanLQ <br /> k <br /> / ! . <br /> �5 MIN I " Maximum daily flow: 600 gpdnal subdivision data <br /> 22 f 18 1 p o <br /> � . . 0 1F <br /> S� ?'PER ADO L.F. MAX. 36" 1 Disposal trench length required: 4 0 75 Lf. 4 <br /> 1 Seepage pits: 4 0 48"0 x 25' deep <br /> 4" PERFORATED DISTRIBUTION PIPE WITH (� un <br /> Q — 5/8" ORIFICES FACING DOWNWARD. <br /> O " — S PER 100 L.F <br /> ORIFICES MAXIMUM PIPE GRADE 2 INCHES z � w <br /> O FACE DOWNWAR q 1-1/2" OR 2-112* DRAIN ROCK <br /> WASHED FREE OF FINE MATERIAL <br /> ' �? " o a <br /> 25DRAIN ROCK 12 o REMOVE SMEARED OR COMP <br /> A <br /> CTED OWNER'S RESPONSIBILITIES <br /> O SURFACES FROM SIDEWALLS <br /> oo ° PRIOR TO BACKFILLING. DO <br /> O V o <br /> NOT WALK IN TRENCHES. ( l <br /> UNDISTURBED SOIL 1_ All septic systems, regardless of type, have finite life spans and as such <br /> O will not operate indefinitely. In accepting this plan, the owner understands <br /> and accepts that repair and/or replacement of all or portions of this <br /> a 4"0 PERF. 24" system will likely be required at some time in the future. <br /> PIPE. EXTEND 2, Proper and diligent monitoring and maintenance will maximize the life of <br /> O TO BOTTOM ON this system and is required. Monitoring & maintenance guidelines were <br /> PIT prepared for this system and were submitted with these plans to the 1` <br /> original owner; these guidelines must be understood and implemented for J <br /> '6 <br /> the system to function reliably. All subsequent owners must secure a <br /> o�5Po5�i! T��Nc� S�cT�oNS copy of, understand, and implement the monitoring and maintenance <br /> guidelines or this design will be considered invalid. <br /> _...... 3. This system is designed to accommodate a finite quantity of domestic <br /> 481------- NO7 TO SCALE wastewater generated by a single--family dwelling. Non—residential <br /> wastewater will not be treated properly by this system and will damage its <br /> components. Wastewater generation exceeding the daily design flow rate <br /> listed elsewhere on these plans is likely to damage the system or cause o <br /> failure and is strictly prohibited. <br /> 4. All toilets and shower heads connected to this system must meet the <br /> i following specifications: toilets shall have a maximum flush rate of 1.6 <br /> gallons per flush; shower heads shall have a maximum flow rate of 2.5 <br /> gallons per minute. <br /> 5. Garbage disposal units will increase the need for septic tank pumping, will <br /> increase the treatment load on the system, and will likely reduce the <br /> system's functional life. These units, therefore, are strongly discouraged. <br /> 6_ Recreational vehicle holding tank chemicals can damage this systems <br /> microbiology and must not be discharged into the system. <br /> 7. The creation of cut banks below the disposal or replacement areas <br /> increases the possibility of interception and surfacing of migrating effluent <br /> and should always be avoided. Cut banks below the disposal or <br /> replacement areas are created solely at the risk of the owner. j <br /> 8. The disturbance of native soils within or below the disposal or I <br /> replacement areas increases the possibility of soil structure damage and R <br /> may lead to disposal field failure. Disturbance of native soils within or tC} <br /> below the disposal or replacement areas by any means including �_ 0 <br /> vehicular traffic, grading, livestock, etc. is prohibited and will invalidate O m m <br /> this design. 03 C� <br /> ti cr7 a O <br /> E <br /> INSTALLER'S RESPONSIBILITIES �°, <br /> m � Q � <br /> 1. Construction of this septic may be undertaken only after obtaining a Q 0 O q <br /> permit from the regulatory outhority(ies). Do not begin construction <br /> prior to approval of this design and issuance of a permit by the <br /> regulatory outhority(ies). The owner and/or installer of this system <br /> is/are solely responsible for identifying and obtaining any other <br /> permits which may be required for construction of this system_ <br /> 2. Inspections during construction by the designer and, in some cases, <br /> the regulatory authority, ore required. The installer and/or owner <br /> are solely responsible for contacting the designer and/or regulatory <br /> authority at least 24 hours in advance of each required inspection. <br /> Every effort will be made to respond within 24 hours, however O <br /> additional notice may sometimes be required. <br /> 3. The permit and an approved set of design documents must be on c N <br /> the job site at all times. U <br /> 4. The installer and/or owner are solely responsible for ensuring that _J V 0) <br /> all property boundaries are accurately marked, that alt appropriate <br /> setbacks are observed, and that underground and/or overhead O ot = U <br /> utilities and/or utility easements are identified prior to construction. W U) <br /> These design documents may not show all present utilities. Z <br /> 5. Under no circumstances shall the disposal or replacement areas, or LJ J O O <br /> the relative positions of the other system components, be modified Q � <br /> without the prior consent of the designer and the regulatory cl� W cQ (J <br /> authority(ies). Q O <br /> 6, If the soil in the disposal area can be formed into a ribbon it is too W <br /> wet to excavate. Do not remove vegetation, operate equipment, or <br /> otherwise manipulate soils in the disposal area until receiving <br /> approval from the designer. <br /> 7. Disturbance of native soils in the disposal and/or replacement areas �P�ct 1sr <br /> and for a distance of 50 feet below the disposal or replacement <br /> areas may damage the permeability of the soil column and cause <br /> premature system failure. Do not allow vehicular traffic, construction r`"PJC) do <br /> equipment, or livestock in the area within or below the disposal or <br /> CD <br /> replacement areas. Q7 � s <br /> 8, Do not direct concentrated surface water runoff onto adjacent Z <br /> properties. <br /> 9. The OSI Simplex control panel utilizes magnetic motor contactors that �-A w <br /> can cause noise and/or vibration in the dwelling if mounted on the Oj yd� <br /> dwelling's exterior wail. Coordinate panel location with the owner <br /> prior to mounting to avoid conflicts. <br /> 10, All disturbed areas shall be seeded at a rate of 5 ibs./1000 s.f. with <br /> FIBERGLASS LID WITH <br /> STAINLESS STEEL BOLTS 24" DIA. RIBBED PI/'C RISER blando brome, annusl rye, or other approved grasses. Applyfertilizer <br /> AND NEOPRENE GASKET, TYP. WITH NEOPRENE GROMMETS AT CONCRETE LID ata rate of 250 lbs./acre and straw mulch ata rote at two tans/acre. <br /> MtpN < <br /> ALL PENETRATIONS, TYP. Z L c iQ <br /> h c! L.2 <br /> TWO—PART EPDXY, TYP. I 4" TIGHTLlNE TO <br /> RISER—TANK JOINTS 4" 0 GRAVITY FEED r . 4F � `, DISPOSAL TRENCH INSPECTIONS BY THE DESIGNER r�is � v O N N <br /> MUST BE WATER TIGHT LINE FROM SEPTIC TANKS : :y a . , ; :.: Z C) Lei. Y 01 <br /> ENSURE JOINT WITH <br /> D—BOX !S WATER TIGHT 0. �' O U N <br /> KNOCK—OUT (TYP.) Inspections by the designer are required at the following stages of construction: U <br /> 4"ABS INLET TEE ,,.i a <br /> TIGHT LINE FROM ' 1 . Layout — The location and layout of the disposal trenches must be approved by <br /> the designer prior to constructionresponsible Contractor is for laying PER UPC <br /> �I <br /> out disposal trenches in advance of the inspection. <br /> 2. Open Trench — After disposal trenches have been excavated and curtain drain trench has <br /> 4. •r!�� <br /> been excavated (if required), but prior to placing drain rock. Septic tank <br /> should be on site. <br /> 6• CONCRETE OR COMPACTED 3• Final — When the system is complete in accordance with the approved <br /> TWO--COMPARTMENT ,. EARTH BASE plans. All system components must be in place and operational. <br /> REINFORCED CONCRETE CONCRETE DISTRIBUTION BOX��•; <br /> SEPTIC TANK. MUST BE SETLEVEL These limited inspections do not allow for detailed examination of all system <br /> WATER TIGHT. components and workmanship and thereby provide only an indication of the installer's <br /> work. The installer is responsible for all workmanship and materials <br /> utilized on the project and for the means and methods of construction. Re—inspections <br /> required due to installer error will be billed to the owner as extra work. <br /> NOTE COVER D-BOX W/ 12 " SOIL COVER <br /> BED TANK ON SELECT <br /> BACKFILL WITH NO ROCKS <br /> LARGER THAN 1-1/2" <br /> D/5 T. BOX <br /> Nor To 5CAL If <br /> fPT/C TANK' 2 � 5 Proprietary components are manufactured by Orenco Systems, Inc. <br /> NOT To SCALE (OSI), 814 Airway Avenue, Sutherlin Oregon. OSI components are <br /> distributed by Senders Hardware in Mountain Ranch, Calaveras County; <br /> Tel: (209) 754-1074. <br /> I <br />