<br /> SEEPAGE PIT LL I O
<br /> NATIVE GRE" FILTER FABRIC DR UNTREATED
<br /> DESIGN DATA
<br /> AD
<br /> FILTER FABRIC 0R UNTREATED L � A
<br /> 1` V
<br /> BUILDING PAPERA NATIVE SOIL BACKFILL TO BE FILTER FABRIC OR UNTREATED
<br /> CAP BUILDING PAPER 18" DEEP (MIN.) BUILDING PAPER GENERAL DESIGN DATA: o
<br /> _ E DISTRIBUTION PIPE o o `J
<br /> Application: 5 bedroom single family dwelling
<br /> j - - ---- ' Water supply: Community water supply `• .,
<br /> 4 , j Septic tank: 2000 gallon septic tank [R
<br /> 4 5' MIN.—L,,, /.� 1 ' / ' ' " ' Percolation tests; See original subdivision dataLQ
<br /> _ J
<br /> 98 Maximum daily design flow: 600 gpd
<br /> .._
<br /> 0 Disposal trench length required: 4 0 75 I.f.
<br /> - -.... S Y PER 700 L F. MAX.
<br /> _ 4" PERFORATED DISTRIBUTION PIPE WITH Seepage pits: 4 48"� x 25' deep
<br /> 5/8" ORIFICES FACING DOWNWARD. U, ([1
<br /> O 0 MAXIMUM PIPE GRADE = 2 INCHES PER 100 L.F `+
<br /> � ORIFICES ° 30 v
<br /> O FACE DOWNWARD ` w
<br /> 1-1/2" OR 2--1/2" DRAIN ROCK � VV
<br /> WASHED FREE OF FINE MATERIAL
<br /> 25 j O 0 a DRAIN ROCK 12" a o
<br /> oo �
<br /> a 0 0 - 40 0 0 0 REMOVE SMEARED OR COMPACTED OWNER'S RESPONSIBILITIES V
<br /> °fir SURFACES FROM 51ING. S
<br /> 1 O ,...O.�. .. _� ,. S2 �- r o.�- �--�_�'_ J PRIOR TO BACKFILLING. DQ
<br /> - �� NOT WALK IN TRENCHES.
<br /> UNDISTURBED SOIL E `
<br /> O I 1. All septic systems, regardless of type, have finite fife spans and as such V
<br /> I will not operate indefinitely. In accepting this plan, the owner understands
<br /> O I24" and accepts that repair and/or replacement of all or portions of this
<br /> 1 4 PERF, system will likely be required at some time in the future. �+
<br /> PIPE. EXTEND
<br /> O 2. Proper and diligent monitoring and maintenance will maximize the life of m
<br /> TO BOTTOM ON p g g 15 `V
<br /> PIT this system and is required. Monitoring & maintenance guidelines were u ` O
<br /> prepared for this system and were submitted with these plans to the Z
<br /> original owner; these guidelines must be understood and implemented for
<br /> the system to function reliably. All subsequent owners must secure a `
<br /> 0/5P05AL6 TiejNC-� 5ffCT/CN5 copy of, understand, and implement the monitoring and maintenance
<br /> guidelines or this design will be considered invalid,
<br /> - - - --- -- _ _ -- -- - - 3. This system is designed to accommodate ❑ finite quantity of domestic
<br /> 48'— NOT TO 5CALf wastewater generated by a single-family dwelling. felon-residential
<br /> wastewater will not be treated properly by this system and will damage its
<br /> components. Wastewater generation exceeding the daily design flow rate \J
<br /> listed elsewhere on these plans is likely to damage the system or cause
<br /> failure and is strictly prohibited. n
<br /> 4. All toilets and shower heads connected to this system must meet the \v}
<br /> following specifications: toilets shall have a maximum flush rate of 1.6
<br /> gallons per flush; shower heads shall have a maximum flow rate of 2.5
<br /> gallons per minute.
<br /> 5. Garbage disposal units will increase the need for septic tank pumping, will
<br /> increase the treatment load on the system, and will likely reduce the
<br /> system's functional life. These units, therefore, are strongly discouraged. j
<br /> 6. Recreational vehicle holding tank chemicals can damage this system's
<br /> microbiology and must not be discharged into the system.
<br /> 7. The creation of cut banks below the disposal or replacement areas
<br /> increases the possibility of interception and surfacing of migrating effluent I
<br /> and should always be avoided. Cut banks below the disposal or
<br /> replacement areas are created solely at the risk of the owner.
<br /> 8. The disturbance of native soils within or below the disposal or I
<br /> replacement areas increases the possibility of soil structure damage and
<br /> may lead to disposal field failure. Disturbance of native soils within or
<br /> below the disposal or replacement areas by any means including p !
<br /> vehicular traffic, grading, livestock, etc. is prohibited and will invalidate O ❑
<br /> this design. O m
<br /> Q) Q
<br /> t
<br /> INSTALLER'S RESPONSIBILITIES
<br /> LU �
<br /> 1, Construction of this septic may be undertaken only after obtaining a co
<br /> permit from the regulatory cuthority(ies). Do not begin construction O Q Q cl� Q�
<br /> prior to approval of this design and issuance of a permit by the
<br /> regulatcry outhority(ies). The owner and/or installer of this system
<br /> is/are solely responsible for identifying and obtaining any other
<br /> permits whiclh may be required for construction of this system.
<br /> 2. Inspections during construction by the designer and, in some cases,
<br /> the regulatory authority, are required. The installer and/or owner
<br /> are solely responsible for contacting the designer and/or regulatory
<br /> authority at least 24 hours in advance of each required inspection.
<br /> Every effort will be made to respond within 24 hours, however ❑
<br /> additional notice may sometimes be required. O N
<br /> 3. The permit and an approved set of design documents must be on
<br /> ct-
<br /> the job site at all times. V N
<br /> 4. The installer and/or owner are solely responsible for ensuring that Lr)
<br /> all property boundaries are accurately marked, that all appropriate
<br /> setbacks are observed, and that underground and/or overhead O Z U
<br /> utilities and/or utility easements are identified prior to construction, Q
<br /> These design documents may not show all present utilities. Q
<br /> 5, Under no circumstances shall the disposal or replacement areas, or W W p
<br /> the relative positions of the other system components, be modified __J Cy
<br /> without the prior consent of the designer and the regulatory Q
<br /> authority(ies). -0 p
<br /> 6. If the soil in the disposal area can be formed into a ribbon it is too 6 � �
<br /> wet to excavate. Do not remove vegetation, operate equipment, or
<br /> otherwise manipulate soils in the disposal area until receiving
<br /> approval from the designer.
<br /> 7. Disturbance of native sails in the disposal and/or replacement areas
<br /> and for a distance of 50 feet below the disposal or replacement ap
<br /> areas may damage the permeability of the soil column and cause z BEY d,�
<br /> premature system failure. Do not allow vehicular traffic, construction � �y`� d
<br /> o
<br /> equipment, or livestock in the area within or below the disposal or
<br /> replacement areas. 's
<br /> 8. Do not direct concentrated surface water runoff onto adjacent U
<br /> properties. Z o
<br /> 9. The OSI Simplex control panel utilizes magnetic motor contactors that yLLJ
<br /> can cause noise and/or vibration in the dwelling if mounted on the p��ydr
<br /> dwelling's exterior wall. Coordinate panel location with the owner i7y��( UJ 5b
<br /> prior to mounting to avoid conflicts.
<br /> FIBERGLASS LID WITH '', 10. All disturbed areas shall be seeded at a rate of 5 lbs./1000 s.f. with
<br /> STAINLESS STEEL BOLTS 24" DIA. RIBBED PVC RISER blando brome, annual rye, or other approved grasses. Apply fertilizer
<br /> AND NEOPRENE GASKET, TYP, WITH NEOPRENE GROMMETS AT at a rate of 250 lbs./acre and straw mulch at a rate of two tons/acre.
<br /> ALL PENETRATIONS, TYP. CONCRETE LID ti N r -
<br /> TWO-PART EPDXY TYP. c 4 N V
<br /> N V-
<br /> N
<br /> 1_4 ca
<br /> RISER-TANK JOINTS 4 TOSAL TR TO
<br /> o NV-
<br /> 4" � GRAVITY FEED DISPOSAL TRENCH INSPECTIONS BY THE DESIGNER � s,, u� z o 'I:
<br /> MUST BE WATER-TIGHT . 4' .• ..
<br /> LINE FROM SEPTIC TANK ` a ,f .; w� V O N N
<br /> ENSURE JOINT WITH :'` z u. m ri
<br /> D---BOX IS WATER TIGHT ° LL Y of
<br /> ' KNOCK—OUT (TYP.) Inspections by the designer ore required at the following stages of construction: © U o a N
<br /> 4" ABS INLET TEE _ } 4.-
<br /> TIGHT LINE FROM —� O
<br /> DWELLING PER UPC j 1 . Layout — The location and layout of the disposal trenches must be approved by PQ a
<br /> ,. the designer prior to construction. Contractor is responsible for laying rnl
<br /> _ P V1
<br /> out disposal trenches in advance of the inspection.
<br /> '`. 2. Open Trench - After disposal trenches have been excavated and curtain drain trench has
<br /> been excavated (if required), but prior to placing drain rock. Septic tank
<br /> 1 f.! should be on site.
<br /> 3. Final — When the system is complete in accordance with the approved
<br /> TWO-COMPARTMENT CONCRETE OR COMPACTED Y P PP
<br /> REINFORCED CONCRETE CONCRETE DISTRIBUTION BOX EARTH BASE plans. All system components must be in place and operational,
<br /> SEPTIC TANK. MUST BE _ SET LEVEL a These limited ins ections do not allow for detailed examination of all system
<br /> WATER TIGHT. P y
<br /> ,a components and workmanship and thereby provide only an indication of the installer's
<br /> work. The installer is responsible for all workmanship and materials
<br /> utilized on the project and for the means and methods of construction. Re—inspections
<br /> /Z j �� ,� required due to installer error will be billed to the owner as extra work.
<br /> NOTE: � COVER D-BOX W/ 12 " SOIL CODER ..
<br /> BED TANK ON SELECT
<br /> BACKFILL WITH NO ROCKS I
<br /> LARGER THAN 1-1/2"
<br /> - I
<br /> 3 0/5 T. BDX
<br /> r
<br /> SEPT/ TA NK NOT TO SCALA
<br /> Proprietary components are manufactured by Orenco Systems, Inc.
<br /> NOT TO 5CALE (OSI), 814 Airway Avenue, Sutherfin Oregon. OSI components are
<br /> distributed by Sender's Hardware in Mountain Ranch, Calaveras County;
<br /> Tel: (209) 754-1074. '
<br />
|