<br /> SEEPAGE PIT
<br /> DESIGN DATA o
<br /> I n'
<br /> FILTER FABRIC OR UNTREATED NATIVE GRADE FILTER FABRIC OR UNTREATED
<br /> BUILDING PAPER BUILDING PAPER NATIVE SOIL BACKFILL TO BE FILTER FABRIC OR UNTREATED V (�
<br /> CAPdISTRIBUTION PIPE 18" DEEP (MIN.) GENERAL DESIGN DATA:
<br /> T-� --
<br /> BUILDING PAPER
<br /> Application: 5 bedroom single family dwelling
<br /> Water supply: Community water supply .,
<br /> f / Septic tank. 2000 gallon septic tank
<br /> i22 j4,'-5' MIN.--� I f .` f`/; f g lPercolation tests: See ori inal subdivision data
<br /> 18" Maximum daily design flow: 600 gpdDisposal trench length required: 4 ® 75 I.f.S e 2' PER 100 L.F. MAX. .3E"pp 4" PERFORATED DISTRIBUTION PIPE WITH Seepage pits: 4 ® 48" x 25' deep
<br /> a a o5/8" ORIFICES FACING DOWNWARD. `� �ORIFICES o a B" MAXIMUM PIPE GRADE = 2 INCHES PER 100 L.F {FACE DOWNWARD-
<br /> 1-1/2" OR 2-1 2" DRAIN ROCK/o / WASHED FREE OF FINE MATERIAL
<br /> Q)
<br /> a o
<br /> u 0 o DRAIN ROCK 12" a 0 0
<br /> O 3 a
<br /> to
<br /> REMOVE SMEARED OR COMPACTED OWNER`S RESPONSIBILITIES_0 a , oc o 0 0 0 0 SURFACES FROM SlDEWALLS
<br /> ,.: PRIOR TO BACKFILLING. DO
<br /> I UNDISTURBED SOIL NOT WALK IN TRENCHES. Cr
<br /> O 1. All septic systems, regardless of type, have finite life spans and as such
<br /> will not operate indefinitely. In accepting this plan, the owner understands o
<br /> O 4"0 PERF. 24" and accepts that repair and/or replacement of all or portions of this
<br /> s stem will like) be re uired at some time in the future.
<br /> Qi
<br /> j6
<br /> J PIPE. EXTEND y y q
<br /> O TO BOTTOM ON 2. Proper and diligent monitoring and maintenance will maximize the life of O '�
<br /> PIT this system and is required. Monitoring & maintenance guidelines were
<br /> prepared for this system and were submitted with these plans to the
<br /> original owner; these guidelines must be understood and implemented for
<br /> the system to function reliably. All subsequent owners must secure a
<br /> 4915P0 Al- T� z ff1 C1-1 ,5�CT10 ,5 copy of, understand, and implement the monitoring and maintenance
<br /> �J �/✓ / , ` � V � / / V guidelines or this design will be considered invalid.
<br /> �48'- _..._.... ._._-._ __.._...._ 3. This system is designed to accommodate a finite quantity of domestic
<br /> NOT TO 5CALE wastewater generated by a single-family dwelling. Non-residential
<br /> wastewater will not be treated properly by this system and will damage its
<br /> components. Wastewater generation exceeding the daily design flow rate `J
<br /> listed elsewhere on these plans is likely to damage the system or cause
<br /> failure and is strictly prohibited. o
<br /> 4. Aii toilets and shower heads connected to this system must meet the
<br /> following specifications: toilets shall have a maximum flush rate of 1.6
<br /> gallons per flush; shower heads shall have a maximum flow rate of 2.5
<br /> gallons per minute.
<br /> 5. Garbage disposal units will increase the need for septic tank pumping, will
<br /> increase the treatment load on the system, and will likely reduce the
<br /> system's functional life. These units, therefore, are strongly discouraged.
<br /> 6. Recreational vehicle holding tank chemicals can damage this system's
<br /> microbiology and must not be discharged into the system.
<br /> 7. The creation of cut banks below the disposal or replacement areas
<br /> increases the possibility of interception and surfacing of migrating effluent
<br /> and should always be avoided. Cut banks befow the disposal or
<br /> replacement areas are created solely at the risk of the owner.
<br /> 8, The disturbance of native soils within or below the disposal or
<br /> replacement areas increases the possibility of soil structure damage and C13
<br /> may lead to disposal field failure. Disturbance of native soils within or
<br /> below the disposal or replacement areas by any means including p
<br /> vehicular traffic, grading, livestock, etc. is prohibited and will invalidate
<br /> this design. �Ll
<br /> O O
<br /> INSTALLER'S RESPONSIBILITIES W
<br /> w -•
<br /> 1. Construction of this septic may be undertaken only after obtaining a Q W iyj
<br /> permit from the regulatory authority(ies). Do not begin construction S ❑ ❑ ❑ rl� ct
<br /> prior to approval of this design and issuance of a permit by the
<br /> regulatory outhority(ies). The owner and/or installer of this system
<br /> is/are solely responsible for identifying and obta;ning any other
<br /> permits which may be required for construction of this system.
<br /> 2. Inspections during construction by the designer and, in some cases,
<br /> the regulatory outhorAy, are required. The installer and/or owner
<br /> are solely responsible for contacting the designer and/or regulatory
<br /> authority at least 24 hours in advance of each required inspection.
<br /> Every effort will be made to respond within 24 hours, however C)
<br /> additional notice may sometimes be required. Q N
<br /> 3. The permit and an approved set of design documents must be on
<br /> the job site at all times. U N
<br /> 4. The installer and/or owner are solely responsible for ensuring that
<br /> all property boundaries are accurately marked, that all appropriate U
<br /> setbacks are observed, and that underground and/or overhead O �Z U
<br /> utilities and/or utility easements are identified prior to construction. LZ 0
<br /> These design documents may not show all present utilities.
<br /> 5. Under no circumstances shall the disposal or replacement areas, or W W j p
<br /> the relative positions of the other system components, be modified d
<br /> without the prior consent of the designer and the regulatoryto
<br /> Q
<br /> authority(ies). W ti Ca
<br /> 6. If the soil in the disposal area can be formed into a ribbon it is too <t
<br /> wet to excavate. Do not remove vegetation, operate equipment, or C', Lo
<br /> otherwise manipulate soils in the disposal area until receiving
<br /> approval from the designer.
<br /> 7. Disturbance of native soils in the disposal and/or replacement areas
<br /> and for a distance of 50 feet below the disposal or replacement aP
<br /> areas may damage the permeability of the soil column and cause
<br /> premature system failure. Do not allow vehicular traffic, construction
<br /> equipment, or livestock in the area within or below the disposal or
<br /> replacement areas. `
<br /> 8. Do not direct concentrated surface water runoff onto adjacent ¢ 1
<br /> properties. W _Z ;3o
<br /> 9. The OSI Simplex control panel utilizes magnetic motor contactors that Z w
<br /> can cause noise and/or vibration in the dwellirg if mounted on the Od ti� Al
<br /> dwelling's exterior wall. Coordinate panel location with the owner �����( Lu 5�
<br /> prior to mounting to avoid conflicts. o�R �
<br /> FIBERGLASS LID WITH 10. All disturbed areas shall be seeded at a rate of 5 lbs./1000 s.f. with
<br /> STAINLESS STEEL BOLTS 24" DIA. RIBBED PVC RISER I blando brome, annual rye, or other approved grasses. Apply fertilizer
<br /> AND NEOPRENE GASKET, TYP. WITH NEOPRENE GROMMETS AT CONCRETE LID at a rate of 250 lbs./acre and straw mulch at a rate of two tons/acre.
<br /> ALL PENETRATIONS, TYP. r•. tv c
<br /> c`O N Q
<br /> ,r- 'n c u_
<br /> TWO-PART EPDXY, TYR F i Q n i
<br /> 4" TIGHTLINE TO
<br /> MUST E W JOINTS 4" 0 GRAVITY FEED DISPOSAL TRENCH INSPECTIONS BY THE DESIGNER �, o
<br /> MUST BE WATER-TIGHT a'
<br /> LINE FROM SEPTIC TANKS : s• •.p r . . U] i�T U O N N
<br /> Z 0 LL CO
<br /> D-BOX IS WATER TIGHT y LL
<br /> U V
<br /> Inspections the d d t the following t f construction:ENSURE JOINT WITH '
<br /> 4" ABS INLET TEE ' KNOCK-OUT (TYP.) :; nspeC ions by e esigner are require a e o owing s ages o cons ruC ion: • U 9 a �,
<br /> TIGHT LINE.FROM O
<br /> DWELLING PER UPC Layout - The location and laIl'-"
<br /> of the disposal trenches must be approved by a
<br /> e designer prior to construction. Contractor is responsible for laying
<br /> ' out disposal trenches in advance of the inspection. 1i6rr� v
<br /> 2. Open Trench — After disposal trenches have been excavated and curtain drain trench has
<br /> been excavated (if required), but prior to placing drain rock. Septic tank
<br /> should be on site.
<br /> TWO-COMPARTMENT 4 CONCRETE OR COMPACTED 3. Final — When the system is complete in accordance with the approved
<br /> REINFORCED CONCRETE ' EARTH BASE plans. All system components must be in lace and operational.
<br /> SEPTIC TANK. MUST $E CONCRETE DISTRIBUTION BOXJ��`,' � .� p y p p p
<br /> WATER TIGHT. SET LEVEL �•e These limited inspections do not allow for detailed examination of all system
<br /> -T-r� • components and workmanship and thereby provide only an indication of the installer's
<br /> .�`• '° / work. The installer is responsible for all workmanship and materials
<br /> f utilized on the project and for the means and methods of construction. Re—inspections
<br /> required due to installer error will be billed to the owner as extra work.
<br /> NOTE., CO VER D---BOX W1 12 " SOIL COVER
<br /> BED TANK ON SELECT
<br /> BACKFILL WITH NO ROCKS
<br /> LARGER THAN 1-112-
<br /> 3
<br /> 0-15 T Z5ox
<br /> NOT TO SCALE
<br /> _ SEPT/C TSI Nf�
<br /> Proprietary components are manufactured by Orenco Systems, Inc. ---- -.-- --- .
<br /> NOT TO 5CAfE (OSI), 814 ,Airway Avenue, Sutherlin Oregon. OSI components are /
<br /> distributed by Sender's Hardware in Mountain Ranch, Coloveras County;
<br /> Tel: (209) .754-1074.