Laserfiche WebLink
I <br /> ' Co o <br /> 0 <br /> I <br /> � o <br /> SEEPAGE PIT <br /> DESIGN DATA o <br /> I n' <br /> FILTER FABRIC OR UNTREATED NATIVE GRADE FILTER FABRIC OR UNTREATED <br /> BUILDING PAPER BUILDING PAPER NATIVE SOIL BACKFILL TO BE FILTER FABRIC OR UNTREATED V (� <br /> CAPdISTRIBUTION PIPE 18" DEEP (MIN.) GENERAL DESIGN DATA: <br /> T-� -- <br /> BUILDING PAPER <br /> Application: 5 bedroom single family dwelling <br /> Water supply: Community water supply ., <br /> f / Septic tank. 2000 gallon septic tank <br /> i22 j4,'-5' MIN.--� I f .` f`/; f g lPercolation tests: See ori inal subdivision data <br /> 18" Maximum daily design flow: 600 gpdDisposal trench length required: 4 ® 75 I.f.S e 2' PER 100 L.F. MAX. .3E"pp 4" PERFORATED DISTRIBUTION PIPE WITH Seepage pits: 4 ® 48" x 25' deep <br /> a a o5/8" ORIFICES FACING DOWNWARD. `� �ORIFICES o a B" MAXIMUM PIPE GRADE = 2 INCHES PER 100 L.F {FACE DOWNWARD- <br /> 1-1/2" OR 2-1 2" DRAIN ROCK/o / WASHED FREE OF FINE MATERIAL <br /> Q) <br /> a o <br /> u 0 o DRAIN ROCK 12" a 0 0 <br /> O 3 a <br /> to <br /> REMOVE SMEARED OR COMPACTED OWNER`S RESPONSIBILITIES_0 a , oc o 0 0 0 0 SURFACES FROM SlDEWALLS <br /> ,.: PRIOR TO BACKFILLING. DO <br /> I UNDISTURBED SOIL NOT WALK IN TRENCHES. Cr <br /> O 1. All septic systems, regardless of type, have finite life spans and as such <br /> will not operate indefinitely. In accepting this plan, the owner understands o <br /> O 4"0 PERF. 24" and accepts that repair and/or replacement of all or portions of this <br /> s stem will like) be re uired at some time in the future. <br /> Qi <br /> j6 <br /> J PIPE. EXTEND y y q <br /> O TO BOTTOM ON 2. Proper and diligent monitoring and maintenance will maximize the life of O '� <br /> PIT this system and is required. Monitoring & maintenance guidelines were <br /> prepared for this system and were submitted with these plans to the <br /> original owner; these guidelines must be understood and implemented for <br /> the system to function reliably. All subsequent owners must secure a <br /> 4915P0 Al- T� z ff1 C1-1 ,5�CT10 ,5 copy of, understand, and implement the monitoring and maintenance <br /> �J �/✓ / , ` � V � / / V guidelines or this design will be considered invalid. <br /> �48'- _..._.... ._._-._ __.._...._ 3. This system is designed to accommodate a finite quantity of domestic <br /> NOT TO 5CALE wastewater generated by a single-family dwelling. Non-residential <br /> wastewater will not be treated properly by this system and will damage its <br /> components. Wastewater generation exceeding the daily design flow rate `J <br /> listed elsewhere on these plans is likely to damage the system or cause <br /> failure and is strictly prohibited. o <br /> 4. Aii toilets and shower heads connected to this system must meet the <br /> following specifications: toilets shall have a maximum flush rate of 1.6 <br /> gallons per flush; shower heads shall have a maximum flow rate of 2.5 <br /> gallons per minute. <br /> 5. Garbage disposal units will increase the need for septic tank pumping, will <br /> increase the treatment load on the system, and will likely reduce the <br /> system's functional life. These units, therefore, are strongly discouraged. <br /> 6. Recreational vehicle holding tank chemicals can damage this system's <br /> microbiology and must not be discharged into the system. <br /> 7. The creation of cut banks below the disposal or replacement areas <br /> increases the possibility of interception and surfacing of migrating effluent <br /> and should always be avoided. Cut banks befow the disposal or <br /> replacement areas are created solely at the risk of the owner. <br /> 8, The disturbance of native soils within or below the disposal or <br /> replacement areas increases the possibility of soil structure damage and C13 <br /> may lead to disposal field failure. Disturbance of native soils within or <br /> below the disposal or replacement areas by any means including p <br /> vehicular traffic, grading, livestock, etc. is prohibited and will invalidate <br /> this design. �Ll <br /> O O <br /> INSTALLER'S RESPONSIBILITIES W <br /> w -• <br /> 1. Construction of this septic may be undertaken only after obtaining a Q W iyj <br /> permit from the regulatory authority(ies). Do not begin construction S ❑ ❑ ❑ rl� ct <br /> prior to approval of this design and issuance of a permit by the <br /> regulatory outhority(ies). The owner and/or installer of this system <br /> is/are solely responsible for identifying and obta;ning any other <br /> permits which may be required for construction of this system. <br /> 2. Inspections during construction by the designer and, in some cases, <br /> the regulatory outhorAy, are required. The installer and/or owner <br /> are solely responsible for contacting the designer and/or regulatory <br /> authority at least 24 hours in advance of each required inspection. <br /> Every effort will be made to respond within 24 hours, however C) <br /> additional notice may sometimes be required. Q N <br /> 3. The permit and an approved set of design documents must be on <br /> the job site at all times. U N <br /> 4. The installer and/or owner are solely responsible for ensuring that <br /> all property boundaries are accurately marked, that all appropriate U <br /> setbacks are observed, and that underground and/or overhead O �Z U <br /> utilities and/or utility easements are identified prior to construction. LZ 0 <br /> These design documents may not show all present utilities. <br /> 5. Under no circumstances shall the disposal or replacement areas, or W W j p <br /> the relative positions of the other system components, be modified d <br /> without the prior consent of the designer and the regulatoryto <br /> Q <br /> authority(ies). W ti Ca <br /> 6. If the soil in the disposal area can be formed into a ribbon it is too <t <br /> wet to excavate. Do not remove vegetation, operate equipment, or C', Lo <br /> otherwise manipulate soils in the disposal area until receiving <br /> approval from the designer. <br /> 7. Disturbance of native soils in the disposal and/or replacement areas <br /> and for a distance of 50 feet below the disposal or replacement aP <br /> areas may damage the permeability of the soil column and cause <br /> premature system failure. Do not allow vehicular traffic, construction <br /> equipment, or livestock in the area within or below the disposal or <br /> replacement areas. ` <br /> 8. Do not direct concentrated surface water runoff onto adjacent ¢ 1 <br /> properties. W _Z ;3o <br /> 9. The OSI Simplex control panel utilizes magnetic motor contactors that Z w <br /> can cause noise and/or vibration in the dwellirg if mounted on the Od ti� Al <br /> dwelling's exterior wall. Coordinate panel location with the owner �����( Lu 5� <br /> prior to mounting to avoid conflicts. o�R � <br /> FIBERGLASS LID WITH 10. All disturbed areas shall be seeded at a rate of 5 lbs./1000 s.f. with <br /> STAINLESS STEEL BOLTS 24" DIA. RIBBED PVC RISER I blando brome, annual rye, or other approved grasses. Apply fertilizer <br /> AND NEOPRENE GASKET, TYP. WITH NEOPRENE GROMMETS AT CONCRETE LID at a rate of 250 lbs./acre and straw mulch at a rate of two tons/acre. <br /> ALL PENETRATIONS, TYP. r•. tv c <br /> c`O N Q <br /> ,r- 'n c u_ <br /> TWO-PART EPDXY, TYR F i Q n i <br /> 4" TIGHTLINE TO <br /> MUST E W JOINTS 4" 0 GRAVITY FEED DISPOSAL TRENCH INSPECTIONS BY THE DESIGNER �, o <br /> MUST BE WATER-TIGHT a' <br /> LINE FROM SEPTIC TANKS : s• •.p r . . U] i�T U O N N <br /> Z 0 LL CO <br /> D-BOX IS WATER TIGHT y LL <br /> U V <br /> Inspections the d d t the following t f construction:ENSURE JOINT WITH ' <br /> 4" ABS INLET TEE ' KNOCK-OUT (TYP.) :; nspeC ions by e esigner are require a e o owing s ages o cons ruC ion: • U 9 a �, <br /> TIGHT LINE.FROM O <br /> DWELLING PER UPC Layout - The location and laIl'-" <br /> of the disposal trenches must be approved by a <br /> e designer prior to construction. Contractor is responsible for laying <br /> ' out disposal trenches in advance of the inspection. 1i6rr� v <br /> 2. Open Trench — After disposal trenches have been excavated and curtain drain trench has <br /> been excavated (if required), but prior to placing drain rock. Septic tank <br /> should be on site. <br /> TWO-COMPARTMENT 4 CONCRETE OR COMPACTED 3. Final — When the system is complete in accordance with the approved <br /> REINFORCED CONCRETE ' EARTH BASE plans. All system components must be in lace and operational. <br /> SEPTIC TANK. MUST $E CONCRETE DISTRIBUTION BOXJ��`,' � .� p y p p p <br /> WATER TIGHT. SET LEVEL �•e These limited inspections do not allow for detailed examination of all system <br /> -T-r� • components and workmanship and thereby provide only an indication of the installer's <br /> .�`• '° / work. The installer is responsible for all workmanship and materials <br /> f utilized on the project and for the means and methods of construction. Re—inspections <br /> required due to installer error will be billed to the owner as extra work. <br /> NOTE., CO VER D---BOX W1 12 " SOIL COVER <br /> BED TANK ON SELECT <br /> BACKFILL WITH NO ROCKS <br /> LARGER THAN 1-112- <br /> 3 <br /> 0-15 T Z5ox <br /> NOT TO SCALE <br /> _ SEPT/C TSI Nf� <br /> Proprietary components are manufactured by Orenco Systems, Inc. ---- -.-- --- . <br /> NOT TO 5CAfE (OSI), 814 ,Airway Avenue, Sutherlin Oregon. OSI components are / <br /> distributed by Sender's Hardware in Mountain Ranch, Coloveras County; <br /> Tel: (209) .754-1074. <br /> r <br /> f <br /> I! <br />