Laserfiche WebLink
15999 W CORRAL HOLLOW RD Project No.2019-00027 P a g e 11 <br /> Table 5. <br /> Summary of Percolation Tests-July 19,2019 <br /> Test No., Percolation percolation Rate Test Comments <br /> Date Tested Test (minutes/inch) Duration (see notes) <br /> Depth(feet) <br /> Site 300-Building T8021 <br /> P-1 (shallow) 3.10 4.39 1 hour Satisfactory <br /> Note: A satisfactory percolation rate for a"shallow"test is less than or equal to 60 minutes per inch. <br /> A satisfactory percolation rate for a"deep"test is less than or equal to 30 minutes per inch. <br /> The soils within the percolation test area for the site have demonstrated a satisfactory percolation <br /> rate in accordance with the requirements of the EHD for the use of a standard septic system. <br /> 7.0 CONCLUSIONS <br /> In summary,percolation rates that meet the minimum EHD standards were achieved in the proposed <br /> septic disposal areas for the subject site;these parcels appear suitable for the use of a standard septic <br /> system. <br /> No ground water was encountered in the boring drilled on the property.The nearest onsite water <br /> well was tested for nitrate and DBCP. Nitrate as nitrogen,nitrate,and nitrite results (non-detected) <br /> are below the MCL of 10 mg/L set by the United States EPA and CA State.DBCP was not detected in <br /> the well tested. <br /> 8.0 LIMITATIONS <br /> The conclusions of this report are established from the information provided regarding the proposed <br /> and existing development,the use of each parcel,and the site conditions as they existed at the time <br /> we excavated our test hole and performed the percolation test. It was assumed that the test hole and <br /> percolation test results are representative of the subsurface conditions in the general area. <br /> If there is a substantial amount of time between the submission of this study and commencement of <br /> work at the site, or if conditions have changed due to construction activities or natural causes at or <br /> adjacent to the site, we recommend that our report be reviewed to access the applicability of the <br /> recommendations and conclusions with consideration regarding changed conditions and or lapse of <br /> time.This report should not be used after 3 years without a review and update from our office. <br /> Our professional services were performed, our findings obtained, and our conclusions proposed in <br /> accordance with generally accepted engineering principles and practices. This warranty is in lieu of <br /> all other warranties either expressed or implied. Test findings and statements of professional <br /> opinion do not constitute a guarantee or warranty,expressed or implied. <br /> Petralogix Engineering,Inc. <br /> 26675 Bruella Road,Galt,Ca 95632 <br /> (209)-400-5729 <br /> www.petralogix.com <br />