My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0012525
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
24061
>
2600 - Land Use Program
>
PA-1900117
>
SU0012525
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/26/2019 2:16:17 PM
Creation date
11/19/2019 1:31:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0012525
PE
2631
FACILITY_NAME
PA-1900117
STREET_NUMBER
24061
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
RIPON
Zip
95366-
APN
25724035
ENTERED_DATE
9/4/2019 12:00:00 AM
SITE_LOCATION
24061 S AUSTIN RD
RECEIVED_DATE
9/3/2019 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
h. BUILDING CODE REQUIREMENTS: The following California Building Code (CBC) and San <br /> Joaquin County Ordinance requirements will be applicable to the proposed project. The following <br /> conditions shall be addressed prior to submittal of a building permit application to the Building <br /> Inspection Division. <br /> (1) A building permit for each separate structure or building is required. Submit plans, <br /> Specifications and supporting calculations, prepared by a Registered Design Professional <br /> (architect or engineer) for each structure or building, showing compliance with the 2016 <br /> California Building, Existing Building, Mechanical, Plumbing, Electrical, Energy and Fire <br /> Codes as may be applicable. Plans for the different buildings or structures may be combined <br /> into a single set of construction documents. <br /> (2) A grading permit will be required for this project. Submit plans and grading calculations, <br /> including a statement of the estimated quantities of excavation and fill, prepared by a <br /> Registered Design Professional. The grading plan shall show the existing grade and finished <br /> grade in contour intervals of sufficient clarity to indicate the nature and extent of the work and <br /> show in detail that it complies with the requirements of the code. The plans shall show the <br /> existing grade on adjoining properties in sufficient detail to identify how grade changes will <br /> conform to the requirements of the code. <br /> (3) The required plans must be complete at the time of submittal for a building permit. Plans <br /> must address building design and construction, fire and life safety requirements, accessibility, <br /> and show compliance with the current California codes and San Joaquin County ordinances. <br /> A complete set of plans must include fire sprinkler plans, truss design submittals, metal <br /> building shop drawings, structural plans and calculations, plumbing, electrical, and <br /> mechanical drawings and energy report. <br /> (4) A soils report is required pursuant to CBC § 1803 for foundations and CBC appendix§ J104 <br /> for grading. All recommendations of the Soils Report shall be incorporated into the <br /> construction drawings. <br /> (5) For each proposed new building, provide the following information on the plans: <br /> a. Description of proposed use <br /> b. Existing and proposed occupancy Groups <br /> c. Type of construction <br /> d. Sprinklers (Yes or No <br /> e. Number of stories <br /> f. Building height <br /> g. Allowable floor area <br /> h. Proposed floor area <br /> i. Occupant load based on the CBC <br /> j. Occupant load based on the CPC <br /> (6) If high piled combustible storage is to be used in a building, an automatic fire sprinkler <br /> system will be required. <br /> PA-1900117 (SA) Conditions of Approval 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.