Laserfiche WebLink
Secondary Containment <br /> Vacuum <br /> Maximize protection with a vacuum t; <br /> monitored secondary containment,`_ <br /> system . <br /> �Y <br /> A Secondary Containment Vacuum Features and Benefits Facilitates penodicoperability tesung <br /> Sensing System for use with Veeder- Satisfy Requirements <br /> • Certified to meet California's requirement for Leverage Existing Veeder-Root Systems <br /> Root's ATG Systems. The Secondary ° • Uses STP as Zwcu mt sourt�and works with <br /> secondary monitoring for tanks and lines <br /> Containment Vacuum Sensing (SCVS) as regime s AB 2481 histallsRed Jacket a SIT s rn <br /> System is designed to detect leaks in double- Sadses the ts for Class I Leak console <br /> v the SIP connects to the <br /> walled tanks and piping systems while Detection as defined by the European console via intrinsically safe wiring <br /> Standard EN 13160 2 • Able to share wiring conduit with other <br /> helping to contain a release of product while Veeder--Root intrinsically safe(IS)probes and <br /> under vacuum.The system consists of: listY National Work Group and LG113 ed seniors induding sump or line leak sensors <br /> • Inttrfaces to the Smart Statsor Interface with <br /> • Vacuum Sensors,connected to tank, Reduce Exposure to Risk Embedded Pressure Module <br /> Alarms when vacuum cannot be maintained • Provides for positive shut down of pressurized <br /> sump or piping interstices or when replenish rate exceeds 85 liters per hour lines when required <br /> • A Submersible Turbine Pump(STP), The system alarms when liquid is detected in • Simple installation,no need to mess with brine <br /> to provide a source of vacuum the secondary space <br /> • A Smart Sensor Interface with Embedded <br /> Pressure Module in a TLS-350 Operating Temperature Rating: Console Capability <br /> Monitoring System -25 degrees C to+70 degrees C The Vacuum Sensor is compatible with <br /> the following consoles: <br /> The Vacuum Sensor is interfaced to Veeder- Cable Length: Console <br /> 8 feet TLS-350R/EMC WOW <br /> Root's TLS-350 Monitoring System via TLS-350 Plus/EMC Enhanced* <br /> intrinsically safe wiring to provide system Sensor Dimensions: TLS-350/EMC• <br /> status,replenish rate,alarm,and diagnostic high x 5"wide 2"deep Upgrade Note:The Vacuum Sensor System requires <br /> the console to have version 24C software(or greater) <br /> information. along with an ECPU2 or ECPU w/NVMEM 1 board. <br /> Standard Models <br /> Vacuum Sensor Kits are available in a variety Veeder-Root P/N Description <br /> Of models: 330020-467 4 Vacuum Sensor K t•for steel tank <br /> 330020-468,469,470.-471 4 Vacuum Sensor Kit'for fiberglass tanks(4',6',8',10') <br /> 330020-486 4 Vacuum Sensor Kir for no tank <br /> • For monitoring double-walled piping 330020-472 3 Vacuum Sensor Kir for steel tank <br /> 330020-473,474,475,476 3 Vacuum Sensor KR'for fiberglass tanks(4',6',8',10) <br /> and sump interstices 330024485 3 Vacuum Sensor Krt•for no tank <br /> • For monitoring double-walled steel tank 330024479 2 Vacuum Sensor Kir for steel tank <br /> interstices(see back page) 330020-481,-482,-483,484 2 Vacuum Sensor Kir for fiberglass tanks(4',6%8',10) <br /> • For double-walled fiberglass tanks 330024480 2 Vacuum Sensor Kit'for no tank <br /> $ 330020-495 1 Vacuum Sensor Kir for no tank <br /> 857284100 Vacuum Sensor for piping 8 sumps <br /> These kits differ In the number OE vacuum 857280-200 Vacuum Sensor for steel tanks <br /> 857284301,-302,-303,-304 Vacuum Sensor for fiberglass tanks(4',6',8%10') <br /> sensors and the configuration of associated 330024448 Mounting Kit <br /> liquid sensors.An inline kit mounted liquid 332217-001 Relief Valve Assembly <br /> sensor is used for Vacuum Sensors 332250.001 Smart Sensor w/Embedded Pressure Sensor Module(7 Channeq'" <br /> monitoring piping and sumps. An external Accessories Part Description Quantity/Length Part Number <br /> 1/4"NPT Barbed Fittings 3 330020-487 <br /> liquid sensor(to be installed in the secondary 1/4"NPT Barbed Fittings 1s 330020-488 <br /> space at the bottom of the tank)is provided 1/4'NPT Barbed Fittings 25 330020-489 <br /> with one of the Vacuum Sensors in the steel Barbed Tee 1 576008-657 <br /> Vacuum Hose 25' 25' 332310-001 <br /> and fiberglass tank kits to monitor the tank. Vacuum Hose 50' 50' 332310.002 <br /> Vacuum Hose 100' 100' 332314003 <br /> 3-Way Ball Valve 1 576008-649 <br /> Schrader Valve Barbed Frtfing 3 330024496 <br /> Schrader Valve Barbed Fitting 15 330020-497 <br /> • Idis include mounting bracket,6'of vacuum hose,relief valve assembly(6 required)and the appropriate number o1 liquid sensors, <br /> i-way bell valves,barbed fittings and hose damps so that each vacuum sensor can monitor a single tank,sump or piping interstices. <br /> The Vacuum Sensing System requires one 7 channel Smart Sensor Interface vrnh Embedded Pressure Module,8 channel Smart <br /> Sensor Modules Win 329356.004)can be used for Vacuum Sensors eight and above. <br /> For more information call: 1-888-561-7942 <br /> �' VEEDER-ROOT <br />