SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility name: Inspection date: <br /> Facility address: UST#/ , <br /> Product ' - <br /> Facility contact: it e: Phone: , <br /> NUk 1 Ghs�-er►�er c� F7`7 <br /> Monitoring panel: iping syste�1;- 2 e II prevention: Violations: <br /> $ <br /> VP-TL <br /> p c72 "�/V /Pressurize Suction Suction C Gravity mechanicaludible/visual =M1-RDetect ❑M2-RPrev Ll M3-Both <br /> Inspection type: Designated orator: 0 ICC exp.date: <br /> �,Koutine Monitoring Certification C Installation 11 Other: '+' * �� <br /> On site Service Technician's name: ICC exp.date: Manufacturer's training: <br /> J'"& VoldV�AC 53 0-79U-VT V L 6 35Y1 t U b 1011 V AA 01 10 N- <br /> # Code Section VIOLATIONS V R <br /> HSC=CA Health&Safety Code; CCR=CA Code of Regulations;V=Violation; RV=Re eat Violation V <br /> 1 HSC 25284 No permit tooperate <br /> Secondary containment: (a)test not performed; (e)test report not submitted within 30 days; (f)test <br /> 2 CCR 2637 notification not provided to the Envir nmental Health Department(EHD)at least 48 hours prior to <br /> conductingthe test I <br /> 3 CCR 2711 b Current Unified Program Consoli ted Forms not on file with the EHD (Facility and tank form) <br /> 4 HSC 25292.2 Current financial responsibility documents not on file with the EHD <br /> 5 CCR 2632(b) Monitoring Program(Monitoring & Response Plans) is not current or approved by the EHD <br /> 6 CCR 2712(i) Monitoring Ian, response plan, and/oroperating permit and all conditions not onsite <br /> Maintenance&monitoring records not maintained 3 years, cathodic protection records for 6'Y2 (M1) <br /> years,written performance claims pertaining to release detection systems for 5 years,or records of <br /> repairs, linings, and upgrades for the life of the tank. Monitoring records include: (1)date and time of <br /> 7 CCR 2712(b) all monitoring or sampling; (2)monitoring equipment calibration and maintenance records; (3) results <br /> of any visual observations; (4)results of sample analysis performed a lab or in the field; (5)logs of all <br /> readings of gauges or other monitoring equipment,ground water elevations,or other test results; (6) <br /> results of inventory readings and reconciliations <br /> 8 CCR 2643(d) Daily monitoring of suction piping (pre-January1, 1984 not performed (M1) <br /> 9 HSC 25292.1 UST system is not operated to prevent unauthorized release, includings ills and overfills <br /> 10 CCR 2632(c)(2) Monitoring system is not present in the interstitials ace of a double walled UST (M1) <br /> 11 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity(mi) <br /> 12 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (M1) <br /> containment <br /> 13 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates (M1) <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631 a Primary containment is not product tight <br /> 15 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 16 CCR 2636(c)(1) All releases in secondary pipingdo not flow to a collection sum <br /> 17 CCR 2636(f)(2) Line leak detectors not installed or failed to detect a 3-gallon per hour leak at 10 psi (M1) <br /> 18 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons, or failed to provide a means (M2) <br /> to keep the spill container empty <br /> 19 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements in this section (M2) <br /> 20 CCR 2636(a) Failed to have secondary containment for piping (includes conventional suction piping) (M2) <br /> 21 1 HSC 25291(e) Water in 20 containment not removed, analyzed &properly disposed of <br /> Unauthorized release that: (c)did not escape secondary containment and cleaned up within eight (M1) <br /> 22 CCR 2650 hours was not recorded; (e) escaped secondary containment, not cleaned up after eight hours,or a <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> 23a CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 da s <br /> 23b CCR 2715(b) Designated operator did not possess a current ICC UST S st e for certification <br /> EHD inspector: Received b : Title: <br /> EHD 23-02-002 REV 06/2,8//10�/T Page 1 UST INSPECTION REPORT <br />