My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2017 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
COMPLIANCE INFO_2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2019 2:36:09 PM
Creation date
11/19/2019 2:48:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J OAQ U I N AMEND Environmental Health Department <br /> B <br /> —COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CRUISERS MANTECA#29 1137 W LATHROP RD, MANTECA August 29, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 9/7/17 and an inspection report was issued identifying information to be submitted to <br /> bring this site into compliance. This information was required to be submitted by 10/7/17. This information was <br /> received on 4/11/18 resulting in a non-compliant status for this facility. An operator that receives an inspection <br /> report shall have 30 days to submit a written response that includes a statement documenting corrective actions <br /> taken or proposing corrective actions which will be taken. Ensure that a written response documenting corrective <br /> actions taken or proposed is submitted within 30 days of receiving an inspection report. <br /> This is a repeat violation, Class ll. <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection.The monitoring plan found on site had <br /> the incorrect line leak detectors.A copy of a an aprove these plans shall be accessible on site at all times. <br /> Immediately locate and retain a copy on site. <br /> This is a repeat violation, Class ll. <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions. <br /> Work order#1612283 was found on site describing the replacement of L4-91 product fill 208 sensor on 8/21/18 and <br /> EHD was not notified of this replacement nor was a permit obtained from the EHD. Emergency repairs relating to <br /> UST system monitoring and release detection may be performed by a properly licensed,trained, and certified <br /> contractor pursuant to the EHD'S policy and a permit, if required, obtained within one business day from the EHD. <br /> Provide proof that EHD was notified of this replacement or obtain a permit from the EHD for the replacement of the <br /> L4 sensor.A"Failure to Obtain a Permit"penalty applies. <br /> This is a repeat violation, Class ll. <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills. <br /> Fuel filters were observed outside of all under dispenser containments at the facility.The underground storage tank <br /> system shall be operated to prevent unauthorized releases. Immediately contact a properly licensed,trained, and <br /> certified contractor to replace or upgrade the component under permit and inspection with the EHD. <br /> This is a Class II violation. <br /> 305 HSC 25290.1(e)VPH monitoring of the interstitial spaces of the UST system is not maintained. <br /> The 87 product STP sump had very little evidence of brine. Loss of brine can be indicative of a leak in the <br /> secondary containment. Secondary containment shall be impervious to the liquid and vapor of the substance <br /> contained and constructed to prevent structural weakening as a result of contact with any hazardous substance <br /> released from the primary containment. Immediately contact a properly licensed,trained and certified contractor to <br /> make repairs to the UST system under permit and inspection of the EHD. <br /> This is a repeat violation, Class II. <br /> FA0019793 PR0530093 SC001 08/29/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.