COMPLIANCE INFO_2017 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
COMPLIANCE INFO_2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2019 2:36:09 PM
Creation date
11/19/2019 2:48:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br /> JA p 1 2018 <br /> D. Results of Testing/Servicin EWRONMENTAL <br /> Software Version Installed: ^ql T�` nP`?,3PTNAENT <br /> Complete the following checklist: <br /> X Yes No' Is the audible alarm operational? <br /> X Yes No' Is the visual alarm operational? <br /> X Yes No' Were all sensors visually inspected,functionally tested.and confirmed operational? <br /> X Yes No' Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br /> proper operation? <br /> X Yes No' If alarms are relayed to a remote monitoring station.is all communications equipment(e g.modem)operational? <br /> X N/A <br /> X Yes No' For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system <br /> NIA detects a leak,fails to operate,or is electrically disconnected? If yes.which sensors initiate positive shut-down? (Check all that apply) <br /> X Sump(Trench Sensors, Dispenser Containment Sensors Did you confirm positive shut-down due to leaks and sensor <br /> failure/disconnection? X Yes, No. <br /> X Yes No' For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e no mechanical overfill prevention <br /> N/A valve is installed),is the overfill warning alarm visible and audible at the tank fill point(s)and operating properly? If so.at what percent <br /> of tank capacity does the alarm trigger? 95 <br /> X No Was any monitoring equipment replaced? If yes, identify specific sensors, probes. or other equipment replaced and list the <br /> Yes' manufacturer name and model for all replacement parts in Section E,below. <br /> X Yes' No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) Product. X Water. If <br /> es,describe causes in Section E.below. <br /> X Yes No' Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> X Yes No' Is all monitoring equipment operational per manufacturer's specifications? <br /> 'In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: REMOVED WATER FROM ALL SUMPS THAT HAD <br /> WATER. <br /> Monitoring System Certification Page 2 of 4 12/07 <br /> ?l?1107 <br />