My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2017 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
COMPLIANCE INFO_2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2019 2:36:09 PM
Creation date
11/19/2019 2:48:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification Form: Addendum for Vacuum/Pressure Interstitial Sensors LG 163-1,Enc.II <br /> 1. Results of Vacuum/Pressure Monitoring Equipment Testing <br /> This page should be used to document testing and servicing of vacuum and pressure interstitial sensors. A copy of <br /> this form must be included with the Monitoring System Certification Form, which must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of the Monitoring System Certification Form to the <br /> local agency regulating UST systems within 30 days of test date. <br /> Manufacturer: VEEDER ROOT Model: 463 System Type: ❑Pressure;®Vacuum <br /> Sensor ID <br /> S1 Component(s)Monitored by this Sensor: 87 PROD_ <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result:®Pass; ❑ Fail <br /> S2 Components)Monitored by this Sensor: --87 VENT <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result:®Pass; ❑ Fail <br /> S3 Component(s)Monitored by this Sensor: 87 ANN <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result:®Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: 87 VAPOR <br /> S4 <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result: ®Pass; ❑ Fail <br /> S5 Component(s)Monitored by this Sensor: 91 PROD <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result: ®Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: 91 VENT <br /> S6 <br /> Sensor Functionality Test Result:❑Pass; ® Fail Interstitial Communication Test Result:❑Pass; ® Fail <br /> S7 Component(s)Monitored by this Sensor: DSL PROD <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result:❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: DSL VENT <br /> -S9 <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result: ®Pass; ❑ Fail <br /> 10 Component(s)Monitored by this Sensor: DSL-91 ANN <br /> S <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result: ®Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass: ❑ Fail Interstitial Communication Test Result: ❑ Pass: ❑ Fail <br /> How was interstitial communication verified? <br /> ® Leak Introduced at Far End of Interstitial Space;' ❑ Gauge; ® Visual Inspection; ❑ Other(Describe in Sec.J,below) <br /> Vacuum was restored to operating levels in all interstitial spaces: ®Yes ❑No(If no, describe in Sec.J, belola-) <br /> J. Comments: S6 FAILED HIGH LIQUID <br /> TEST <br /> 'A w4 <br /> � 0 rt� <br /> ENV!MONMENTAL <br /> F1r I TL-1 DFS"° ''_ <br /> -7, , 7 <br /> If the sensor suc ly detects a simulated vacuum/pressure leak introduced in the interstitial space at the furthest point from the <br /> sensor,vacuum/pressure has been demonstrated to be communicating throughout the interstice. <br />
The URL can be used to link to this page
Your browser does not support the video tag.