My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2017 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
COMPLIANCE INFO_2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2019 2:36:09 PM
Creation date
11/19/2019 2:48:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification „ <br /> D. Results of Testing/Servicing <br /> I <br /> Software Version Installed: <br /> CDttl tete the folio in&checklists <br /> I <br /> CI Y ❑ No* Is the audible alarm operational? <br /> Cl Yes ❑ No* Is the visual alarm operational? <br /> CI Yes ❑ No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> Cl Yes C1 No* Were all sensors installed at lowest poirit of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> CI Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) <br /> ❑ N/A oPerational? <br /> CI Yes ❑ NO For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:-which sensors initiate <br /> positive shut-down? (Check all that apply) ❑Sump french Sensors; ❑Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks fLnd sensor failure/disconnection? ❑Yes; ❑No. <br /> t <br /> , <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no <br /> ❑ N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank i <br /> (ill point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? 95% 1 <br /> [) Yes* O No Was any monitoring equipment re laced? If yes,identify specific sensors,probes,or other equipment re laced 3 <br /> f <br /> and list the manufacturer name and model for all replacement parts in Section 1 ,below. I <br /> Cl Yes* 0 No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> _ ❑Product; ❑Water, If yes,describe causes in Section E,below. <br /> C] Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable j <br /> [I Yes C) No* Is all monitoring equipment operational per manufacturer's speci fications? <br /> i`In Section E below,describe how,and when these deficiencies were or will be corrected. <br /> i <br /> F;. Comments: Test after repairs. Brine communication,304 sensor,and 20B sensor tested in Diesel fill sump. <br /> I <br /> ( <br /> I <br /> , <br /> h <br /> r <br /> L <br /> i <br /> l <br /> IIN-036- 3/6 www.unidomor6 Rev.OUly/66 <br /> i <br /> i <br /> � 1 <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.