Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sjgov.org/ehd -- <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CRUISERS MANTECA#29 1 1137 W LATHROP RD, MANTECA September 07, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms for the Tank ID#TA0518496 are not current in CERS. Under"Vent, Vapor Recovery <br /> (VR) and Riser/Fill Pipe Piping Construction" the"Vapor Recovery Primary Containment" should be blank. For all <br /> three tanks under"Tank Construction" a more adequate selection should be made for the"Secondary Containment' <br /> material, change"Yes" to"No" for"Ball Float' under"Overfill Protection", under"Vent, Vapor Recovery (VR) and <br /> Riser/Fill Pipe Piping Construction" the"Vent Piping Transition Sumps" should be double-walled. Any change of <br /> information must be updated in CERS within 30 days of the changes. Immediately log into CERS, update the <br /> required information, and submit for review by the EHD <br /> This is a Class II violation. <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. For all three tanks the monitoring panel model <br /> number should be "350 Plus" and needs to be updated wherever the model number is referenced, in "Tank <br /> Monitoring is Performed Using the Following Method(s)" vacuum should be under"Secondary Containment <br /> System" and under"Leak Sensor Model" change "208"to the correct annular sensor model number and vacuum <br /> sensor model number, in the "Piping Monitoring is Performed Using the Following Method(s)"change "No"to "Yes" <br /> for"Continuous Monitoring of Piping Secondary Containment' and fill out all corresponding information , change <br /> "Yes"to "No"for"Mechanical Line Leak Detector Performs 3 GPH Leak Test' and change "No"to "Yes" under <br /> "Electronic Line Leak Detector Performs 3 GPH Leak Test" and fill out all corresponding information, under"Under <br /> Dispenser Containment(UDC) Monitoring" make changes to reflect that the monitoring is continuous and enter all <br /> sensor and UDC panel information, "Detection of Leak into UDC Triggers Audible and Visual Alarms" should be <br /> "Yes", "UDC Leak Alarm Triggers Automatic Pump Shutdown" should be "Yes", "Failure/Disconnect of UDC <br /> Monitoring System Triggers Automatic Pump Shutdown" should be yes, "UDC Monitoring Stops Flow of Product at <br /> Dispenser" should be "No" "UDC Construction" should be double walled, "UDC Secondary Containment Monitoring" <br /> should be liquid and "Leak Within Secondary Containment of UDC causes Audible and Visual Alarms" should be <br /> "Yes". For Tank ID#TA0518494 under"Piping Monitoring is Performed Using the Following Method(s)"change <br /> "Yes"to "No for"Pipeline Integrity Testing" and under"Leak Sensor Manufacturer" change "Red Jacket'to Weeder <br /> Root' and add the vacuum "smart" sensor model number to the-"Leak Sensor Model". The monitoring plan must be <br /> uploaded to the California Environmental Reporting System (CERS). Immediately log into CERS, make the <br /> necessary changes, and submit for review by the EHD. <br /> This is a repeat violation, Class II. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. Away to identify symbols and letters associated with <br /> monitoring plan should be provided to identify all components of system. Sumps should be drawn to include all the <br /> monitoring components found in it and "Liquid line leak detectors (VMI) in sumps" locations do not reflect actual <br /> location of the line leak detectors. A site plan must be submitted identifying the locations where monitoring will be <br /> performed. Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> This is a minor violation. <br /> FA0019793 PR0530093 SCO01 09/07/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 8 Underground Storage Tank Program OIR <br />