Laserfiche WebLink
Spargerw Analytical Laboratory Division <br /> Mobile Laboratory Division <br /> Technonc.y IScientific Division <br /> With Automation rn MrnC <br /> III Quality Control <br /> A. Protect Specific QC. No project specific QC (i.e., spikes and/or <br /> duplicates) was requested. <br /> B. Method Blank Results. A method blank is a laboratory-generated <br /> sample which assesses the degree to which laboratory operations and <br /> procedures cause false-positive analytical results for your sample. <br /> No target parameters were detected in the method blank associated <br /> with your sample at the reporting limit levels noted on the data sheets <br /> in the Analytical Results section. <br /> C. Laboratory Control Spike. A Laboratory Control Spike (LCS) is a <br /> sample which is spiked with 30 ppb BTEX, and analyzed at <br /> approximately 10% of the sample load in order to establish method- <br /> specific control limits. The LCS results associated with your samples <br /> are on the attached 8020 Modified LCS BTEX Analysis Report. <br /> Accuracy is measured by Percent Recovery as in: <br /> % recovery = (measured concentration) x 100 <br /> (actual concentration) <br /> IV Analysis Results <br /> Results are on the attached data sheets. <br /> 3C50 Fire Circle. Surae ^^,� ccrc,^^cr„o, Co.':;cmrc =�a�i (916) 362-8947 • FAX (916) 362-0947 <br />