Monitoring System Certification eco,/ <br /> «,.0,CK COMM!-CE <br /> D. Results of Testing/Servicing <br /> Software Version Installed: 333.02 <br /> Complete the following checklist: <br /> M Yes ❑ No* Is the audible alarm operational? <br /> M Yes ❑ No* Is the visual alarm operational? <br /> M Yes ❑ No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> M Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) <br /> M N/A operational? <br /> * l'es ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak, fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-down? (Check all that apply) M Sump/Trench Sensors; M Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? M Yes; ❑No. <br /> M Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no <br /> ❑ N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? 90% <br /> M Yes* ❑ No Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑ Yes* M No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑ Product; ❑ Water. If yes,describe causes in Section E,below. <br /> M Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> M Yes ❑ No* 1 Is all monitoring equipment operational per manufacturer's specifications? <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: Tank#2 and Tank#3 are partitions of one tank—only one Annualar Sensor is installed. <br /> Additional the following equipment is connected to the monitoring system: <br /> 1.Veeder Root—794380-304 Sensor monitoring the 87 Piping Sump Annualar <br /> 2.Veeder Root—794380-304 Sensor monitoring the 91 Piping Sump Annualar-REPLACED during the test. <br /> 3.Veeder Root—794380-304 Sensor monitoring the Diesel Piping Sump Annualar <br /> 4.Veeder Root—794380-304 Sensor monitoring the 87 Fill Sump Annualar <br /> 5.Veeder Root—794380-304 Sensor monitoring the 91 Fill Sump Annualar <br /> 6.Veeder Root—794380-304 Sensor monitoring the Diesel Fill Sump Annualar. <br /> 7.Veeder Root—794380-304 Sensor monitoring the Under Dispenser Containment#112 Annualar <br /> 8.Veeder Root—794380-304 Sensor monitoring the Under Dispenser Containment#3/4 Annualar <br /> 9.Veeder Root—794380-304 Sensor monitoring the Under Dispenser Containment#5/6 Annualar <br /> 10.Veeder Root—794380-304 Sensor monitoring the Under Dispenser Containment#7/8 Annualar <br /> 11. Veeder Root—794380-304 Sensor monitoring the Under Dispenser Containment#9/10 Annualar <br /> 12. Veeder Root—794380-304 Sensor monitoring the Under Dispenser Containment#11/12 Annualar <br /> 13. Veeder Root—794380-304 Sensor monitoring the Vent Sump Annular <br /> 14. Veeder Root—794380-304 Sensor monitoring the Vent Sump-All additional sensors were tested. <br /> Pa(-'e 3 of 6 <br />