Laserfiche WebLink
... a � .. <br /> TLS-350 Monitoring System Requirement's`" 2 5 2014 Assist ISD <br /> •TIS-350 with ECPU2 Part Numer Description Requirement <br /> •NVMEM 203 ENVIRONMENTAL HEALTH 330020-445 Assist Vapor Flow Meter Kit 1 per dispenser <br /> •RS-232 Interface Module for On-site PC re <br /> gPc8@TM ENT 330020-515 Wired Vapor Pressure Sensor Kit' <br /> •Smart Sensor Module 861190-201 "E"Wireless Vapor Pressure Sensor Kit' 1 per site <br /> 330020-715 "r"'Vapor Pressure Sensor Site Start-up KIN <br /> •Dispenser Interface Module(DIM) <br /> 332250-110 Seven Input Smart Sensor Modules <br /> • 1 per seven or eight <br /> ISD Software Enhancement Module(SEM) <br /> 329356-004 Eight Input Smart Sensor Module Smart Sensors <br /> •Site Shutdown Control Hardware <br /> Alarm Table Balance ISD <br /> The lollowin,mole contains a list of warnings and alarms posted or Part Numer Description Requirement <br /> used by the ISD System: 330020-585 Balance Vapor Flow Meter Kit 1 per dispenser <br /> Balance Assist Warning Days to Description <br /> 330020-515 Wired Vapor Pressure Sensor Kit' <br /> ISD ISD Alarm <br /> 861190-201 "r"Wireless Vapor Pressure Sensor Kit' 1 per site <br /> X X ISD DEGRD PRESSURE 30 751"percentile of 30 days'ullage "Ew , <br /> pressure that exceeds 0.3 IWC 330020-715 Vapor Pressure SensorSite Start-up Kit <br /> 95"percentile of 7 days'ullage 332250-001 Seven Input Smart Sensor Modules 1 per seven or eight <br /> X X ISO GROSS PRESSURE 7 <br /> pressure that exceeds 1.3 IWC 329356-004 Eight Input Smart Sensor Module Smart Sensors <br /> X X ISD VAPOR LEAKAGE 7 Containment system leaks at two 847490-315 PMC Port Controller Module' 1 per TLS Console <br /> times the TP 201.3 standard <br /> X X ISD SENSOR OUT 7 Failure of Sensor Self-test TLS-350 Software/Memory <br /> X x ISD SETUP 7 Failure of Setup Test Upgrade Options for ISD <br /> X Hnn:DEGRD COLLECT 7 7-day Degradation AIL Test Part Numer Description Requirement <br /> X Hnn:GROSS COLLECT 1 1-day Gross AIL Test Warning 331500-358 ECPU2,latestV.3XX software,NVMEM 203 <br /> Vapor collection flow perfomance 331500-322 Latest V.3XX software,NVMEM 203 <br /> X Hnn:FLOW COLLECT is less than 50% <br /> 332966-203 NVMEM 203(report storage) 1 per Console <br /> X ISD VP PRESSURE 1 90'"percentile of 1-day ullage 330160-004 ISD Software Enhancement Module(SEM) <br /> pressure exceeds 2.5 IWC <br /> 331500-353 TLS V3XX software <br /> X ISD VP EMISSIONS 1 Mass emission exceeded the <br /> certified threshold <br /> Failure of Vapor Processor Effluent Optional ISD Components <br /> X ISD VP Status 1 Emissions or Duty Cycle Test <br /> Part Numer Description Requirement <br /> 6, <br /> 331408-001 Dispenser Control Module for Single 1 module per <br /> Dispenser Shutdown 4 dispensers <br /> Typical ISD Configuration l� <br /> Vapor Pressure Sensor Kit for Mounting <br /> Carbon Canister 330020-630 on Vent Stack' 1 per Console <br /> I <br /> I 1 per Pressure Sensor <br /> t <br /> Dispenser Island 330020-716 Universal Enclosure Box when mounted on <br /> I Vent Stack <br /> 330020-717 "E"'Vapor Pressure Sensor Drying Tube Kit Replacement Part <br /> TLS Console ISD t <br /> n Pressure 1. Can only be used on wired installations. <br /> Sensor <br /> wlenclosure 2. Can only be used on wireless installations. <br /> - (Installation ; 3. Required when ordering 861190-201 sensor for wireless installations. <br /> Only l <br /> Option 2) i I 4. red for VST Vapor ISD O l � � : t Y reuor Processors.q � P <br /> Flowmeter t t I + wired sor <br /> s i 5.At least one seven channel module required when installing Carbon Canister Vapor <br /> ell111 <br /> t r I wireless , polisher,optional on all other ISD sites. <br /> Irll <br /> ISD Pressure Sensor <br /> (Installation Option 1) <br /> Wired Only To learn more, contact us at.888.561.7942, or visit www.veeder.com. <br /> 125 Powder Forest Drive,P.O.Box 2003,Simsbury,CT 06070 USA <br /> VEEDER-ROOT <br /> "> ©2013 Veeder-Root Company • 576047-065 Rev.F • Printed in USA <br />