Laserfiche WebLink
DELIVERY L I I°1 I T 13% <br /> IN-TANK SETUP 1400 L 3:91 STP SUMP <br /> - - - - - - - - - - - - TRI-STATE (SINGLE FLOAT) <br /> LOW PRODUCT 500 CATEGORY : STP SUMP <br /> T 1 :UNLEADED R LEAK ALARM LIMIT: 99 <br /> PRODUCT CODE I SUDDEN LOSS LIMIT: 99 <br /> THERMAL COEFF : .000700 TANK TILT - 0.50 L 4:92 ANN SPACE <br /> TANK DIAMETER' 128.00 PROBE OFFSET 0.50 TRI-STATE (SINGLE FLOAT) <br /> TANK PROFILE 1 FT CATEGORY : ANNULAR SPACE <br /> FULL VOL 20000 SIPHON MANIFOLDED TANKS <br /> T#: NONE <br /> FLOAT SIZE: " 4.0 IN. LINE MANIFOLDED TANKS L 5:DISP 1-2 <br /> T#: NONE TRI-STATE (SINGLE FLOAT) <br /> WATER WARNING 2.0 CATEGORY : DISPENSER PAN <br /> HIGH WATER LIMIT: 3.0 LEAK MIN PERIODIC: 0% <br /> MAX OR LABEL VOL: 20000 0 <br /> OVERFILL LIMIT 901/0 PERIODIC TEST TYPE L 6:DISP 3-4 <br /> 18000 STANDARD TRI-STATE (SINGLE FLOAT) <br /> HIGH PRODUCT 95% CATEGORY : DISPENSER PAN <br /> 19000 PERIODIC TEST FAIL <br /> DELIVERY LIMIT7% ALARM DISABLED <br /> .1400 GROSS TEST FAIL L 7:DISP 5-6 <br /> LOW PRODUCT 500 ALARM DISABLED TRI-STATE (SINGLE FLOAT) <br /> LEAK ALARM LIMIT: 99 PER TEST AVERAGING: OFF CATEGORY : DISPENSER PAN <br /> SUDDEN LOSS LIMIT: 99 <br /> TANK TILT 0.00 <br /> PROBE OFFSET 0.00 TANK TEST NOTIFY: OFF <br /> L B:DISP 7-8 <br /> TNK TST SIPHON BREAKOFF TRI-STATE (SINGLE FLOAT) <br /> SIPHON MANIFOLDED TANKS CATEGORY : DISPENSER PAN <br /> T#: NONE DELIVERY DELAY 5 MIN <br /> LINE MANIFOLDED TANKS PUMP THRESHOLD 10.00% <br /> T#: NONE <br /> LEAK MIN PERIODIC: 0% <br /> 0 <br /> PERIODIC TEST TYPE <br /> STANDARD <br /> PERIODIC TEST FAIL <br /> ALARM DISABLED <br /> GROSS TEST FAIL OUTPUT RELAY SETUP <br /> ALARM DISABLED LEAK TEST METHOD - - - - - - - - - - - - <br /> PER TEST AVERAGING: OFF TEST ON DATE : ALL TANK R 1 :87 STP <br /> JAN 29. 2009 TYPE: <br /> TANK TEST NOTIFY: OFF START TIME : DISABLED STANDARD <br /> TEST RATE :0.20 GAL/HR NORMALLY CLOSED <br /> TNK TST SIPHON BREAKOFF DURATION : 2 HOURS <br /> DELIVERY DELAY 5 MIN TST EARLY STOP:DISABLED TANK #: 1 <br /> PUMP THRESHOLD 10.00% LEAK TEST REPORT FORMAT LIQUID SENSOR ALMS <br /> NORMAL L 1 :FUEL ALARM <br /> L 5:FUEL ALARM <br /> L 6:FUEL ALARM <br /> L 7:FUEL ALARM <br /> L B:FUEL ALARM <br /> L 1 :SENSOR OUT ALARM <br /> L 5:SENSOR OUT ALARM <br /> L 6:SENSOR OUT ALARM <br /> L 7:SENSOR OUT ALARM <br /> L B:SENSOR OUT ALARM <br /> T 2:UL PREMIUM L 1 :SHORT ALARM <br /> PRODUCT CODE 3 L 5:SHORT ALARM <br /> THERMAL COEFF : .000700 LIQUID SENSOR SETUP L 6:SHORT ALARM <br /> TANK DIAMETER 96.00 - - - - - - - - - - - - L 7:SHORT ALARM <br /> TANK PROFILE 1 PT L B:SHORT ALARM <br /> FULL VOL 10020 L 1 :87 STP SUMP <br /> TRI-STATE (SINGLE FLOAT) ISD SITE ALARMS <br /> CATEGORY : PIPING SUMP ISD GROSS PRES FAIL <br /> FLOAT SIZE: 4.0 IN. ISD DEGRD PRES FAIL <br /> ISD VAPOR LEAK FAIL <br /> L 2:87 ANN SPACE <br /> WATER WARNING 2.0 ISD VP PRES FAIL <br /> HIGH WAFER LIMIT: 3.0 TRI-STATE (SINGLE FLGAT) <br /> CATEGORY : ANNULAR SPACE ISD HOSE ALARMS <br /> MAX OR LABEL VOL: 10000 ALL:GROSS COLLECT FAIL <br /> OVERFILL LIMIT 90% ALL:DEGRD COLLECT FAIL <br /> 9000 ALL:FLOW COLLECT FAIL <br /> HIGH PRODUCT 95% <br />