My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
440
>
2300 - Underground Storage Tank Program
>
PR0231055
>
COMPLIANCE INFO_2012 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/27/2019 3:47:04 PM
Creation date
11/26/2019 9:20:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2018
RECORD_ID
PR0231055
PE
2361
FACILITY_ID
FA0002321
FACILITY_NAME
Delta arco
STREET_NUMBER
440
Direction
W
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
16503003
CURRENT_STATUS
01
SITE_LOCATION
440 W DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
364
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LOW PRODUCT 500 GROSS TEST FAIL L 7:DISP 5-6, <br /> .LEAK ALARM LIMIT: 99 ALARM DISABLED TRI-STATE (SINGLE FLOAT) <br /> ' SUDDEN LOSS LIMIT: 99 CATEGORY : DISPENSER PAN <br /> TANK TILT 0.00 PER TEST AVERAGING: OFF <br /> PROBE OFFSET 0.00 <br /> TANK TEST NOTIFY: OFF <br /> SIPHON MANIFOLDED TANKS TNK TST SIPHON BREAKOFF L B:DISP 7-8 <br /> TRI-STATE (SINGLE FLOAT) <br /> T#: NONE DELIV CATEGORY DISPENSER PAN <br /> LINE MANIFOLDED TANKS PUMP THRESHOLD 15 MIN <br /> T#: NONE <br /> LEAK MIN PERIODIC: 0 <br /> 0 <br /> PERIODIC TEST TYPE <br /> STANDARD <br /> PERIODIC TEST FAIL <br /> ALARM DISABLED <br /> GROSS TEST FAIL <br /> ALARM DISABLED LEAK TEST METHOD OUTPUT RELAY SETUP <br /> _ _ _ _ _ _ _ _ _ _ _ _ <br /> PER TEST AVERAGING: OFF - - - - - - - - - - - - <br /> TEST ON DATE : ALL TANK R 1 :87 STP <br /> TANK TEST NOTIFY: OFF JAN 29. 2009 <br /> START TIME : DISABLED TAPE: <br /> TNK TST '31OHON BREAK OFF TEST RATE :0.20 GAL/HR STANDARD <br /> DURATION 2 HOURS NORMALLY CLOSED <br /> DELIVERY DELAY 5 MIN o TANK <br /> STOP #: 1 <br /> PUMP THRESHOLD 10.00% TST EARLY :DISABLED <br /> LEAK TEST REPORT FORMAT LIQUID SENSOR ALMS <br /> NORMAL L 1 :FUEL ALARM <br /> L 5:FUEL ALARM <br /> L 6:FUEL ALARM <br /> L 7:FUEL ALARM <br /> L 8:FUEL ALARM <br /> L 1 :SENSOR OUT ALARM <br /> L 5:SENSOR OUT ALARM <br /> L 6:SENSOR OUT ALARM <br /> T 2:UL PREMIUM L 7:SENSOR OUT ALARM <br /> PRODUCT CODE 3 L S:SENSOR OUT ALARM <br /> THERMAL COEFF : .000700 L 1 :SHORT ALARM <br /> TANK DIAMETER 96.00 LIQUID SENSOR SETUP L S:SHORT ALARM <br /> TAN}; PROFILE 1 PT - - - - - - - - - - - - L 6:SHOkT ALARM <br /> FULL VOL 10020 L 7:SHORT ALARM <br /> L 1 :87 STP SUMP L 8:SHORT ALARM <br /> TRI-STATE (SINGLE FLOAT) <br /> FLOAT SIZE: 4.0 IN. CATEGORY : PIPING SUMP ISD SITE ALARMS <br /> ISD GROSS FRES FAIL <br /> WATER WARNING : 2.0 ISD DEGRD PRES FAIL <br /> HIGH WATER LIMIT: 3.0 L 2:57 ANN SPACE ISD VAPOR LEAK FAIL <br /> TRI-STATE (SINGLE FLOAT) ISD VP PRES FAIL <br /> MAX OR LABEL VOL: 10000 CATEGORY : ANNULAR SPACE ISD HOSE ALARMS <br /> OVERFILL LIMIT 90i ALL:GROSS COLLECT FAIL <br /> 9000 ALL:DEGRD COLLECT FAIL <br /> HIGH PRODUCT 95% ALL:FLOW COLLECT FAIL <br /> 9500 L 3:91 STP SUMP <br /> DELIVERY LIMIT 13% TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : STP SUMP k 2:91 STP <br /> 1400 TYPE: <br /> LOW PRODUCT 500 STANDARD <br /> LEAK ALARM LIMIT: 99 L 4:92 ANN SPACE IVORNIALLY CLOSED <br /> SUDDEN LOSS LIMIT: 99 TRI-STATE (SINGLE FLOAT) TANK #: 2 <br /> TANK TILT 0.50 CATEGORY : ANNULAR SPACE <br /> PROBE OFFSET 0.50 <br /> LIQUID SENSOR ALMS <br /> SIPHON MANIFOLDED TANKS L 5:DISP 1-2 L 3:FUEL ALARM <br /> L 5:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) <br /> T#: NONE <br /> LINE MANIFOLDED TANKS CATEGORY : DISPENSER PAN L 6:FUEL ALARM <br /> L 7:FUEL ALARM <br /> T#: NONE L 8:FUEL ALARM <br /> L 3:SENSOR OUT ALARM <br /> LEAK MIN PERIODIC: 0%, L 6:DISP 3-4 L 5:SENSOR OUT ALARM <br /> 0 TRI-STATE (S,INGLE FLOAT) L 6:SENSOR OUT ALARM <br /> PERIODIC TEST TYPE CATEGORY : DISPENSER PAN L 7:SENSOR OUT ALARM <br /> L 8:SENSOR OUT ALARM <br /> STANDARD L 3:SHORT ALARM <br /> PERIODIC TEST FAIL L 5:SHORT ALARM <br /> ALARM DISABLED T. (,:,SHORT ALARM <br />
The URL can be used to link to this page
Your browser does not support the video tag.