My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
440
>
2300 - Underground Storage Tank Program
>
PR0231055
>
COMPLIANCE INFO_2012 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/27/2019 3:47:04 PM
Creation date
11/26/2019 9:20:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2018
RECORD_ID
PR0231055
PE
2361
FACILITY_ID
FA0002321
FACILITY_NAME
Delta arco
STREET_NUMBER
440
Direction
W
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
16503003
CURRENT_STATUS
01
SITE_LOCATION
440 W DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
364
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN.JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s4gov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Naley Delta Arco Facility Inspection 440 W. Dr. MILK, Jr. Blvd., Stkn Dateon Jul 11, 2012 <br /> Facility Title: <br /> Contact: Major Singh Owner rPM*) 465-2487 <br /> Inspection X Routine X Monitoring System Certification i i Installation i I Complaint-ID* Other: <br /> Type: <br /> (Authority HSC 25289) Major Singh Owner <br /> Consentfor. Xinspection XSampling XPhotos Granted by: g Title: <br /> Monitoring Gilbarco EMC Piping Overfill <br /> Panel: System: XPressurized I1 Suction i i Gravity Prevention: XMechanical i i Audible/visual <br /> USTDate: <br /> 10 11 <br /> Product 87-octan- -- -- 1-1--- - - - - - - - ------------- -------------- - - - - -------------- <br /> -------- ------------ -------------- <br /> 91-octane <br /> Designated <br /> ted Dave Winkler ICC Exp. <br /> Operato3/2/14 Violations: XM1-Release Detection !i M2-Release Prevention i M3-Both <br /> O r <br /> site service Dave Winkler ICC 6cp. 3/5/14 Manufacturers <br /> Te VR X. 2/13/14 VMI X. 11/10/13 <br /> Technician: Date: Training: <br /> VIOLATIONS <br /> # I C1 C2 M Code S@Ction HSC=California Health and Safety Code;CCR=California Code of Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> File Review <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tanks stem <br /> 104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Fortes not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br /> 108 X CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test notification <br /> not provided to the EHD at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 X CCR 2638 (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 HSC 25291(f) Annual line leak detector test not performed (M1) <br /> 111 HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (111112) <br /> permit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 1000'of public well,or <br /> failures not repaired and retested <br /> 117 CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 HSC 25298(b) Permit to temporarily Gose UST system not obtained <br /> 120 HSC 25298(c) Permit to dose UST system not obtained <br /> On Site Records <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6 Y2 years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment,ground water elevations,or other test results; 6 results of inventory readings and reconciliations <br /> 202 CCR 2712(i) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (M1) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned ul after eight hours,or a sudden lass of <br /> product was not reported to the EHD within 24 hours <br /> Inspector Received By: ��� TiUe: /1 4 <br /> Stacy Rivera (209) 468-3440 o-1 fJ �" <br /> EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.