Laserfiche WebLink
FUTURE _ <br /> ISD SYSTEM REQUIREMENTS: ALARM TABLE: RE!PROVEN'DY <br /> The following table contains pan numbers, The following table contains a list of warnings <br /> as well as descriptions of the ISD components: and alarms generated by the ISD system: PAST <br /> Assist ISD <br /> Part Number Description Quantity Balance Assist Warning Days to Description <br /> 330020-445 Assist Vapor Flow Meter Kit 1 per dispenser ISD ISD Alarm Alarm <br /> 330020-515 Vapor Pressure Sensor Kit 1 per site X X ISD DEGRD PRESSURE 30 Vapor Overpressure Problem <br /> 331943-203 NVMEM 2(Report Storage) 1 per site x X ISD GROSS PRESSURE 7 Vapor Overpressure Problem <br /> 330160-xxx ISD Software Enhancement 1 per site X X ISD VAPOR LEAKAGE 7 Vapor Leakage Problem <br /> Module SEM <br /> X X ISD SENSOR OUT 7 Optional Sensor Problem <br /> Balance ISD <br /> X X ISD SETUP 7 Optional Setup problem <br /> Part Number Description Quantity X Hnn:DEGRD COLLECT 7 Hose A/L Problem <br /> 330020.585 Balance Vapor Flow Meter Kit 1 per dispenser X Hnn:GROSS COLLECT 1 Hose Blockage or A/L Problem <br /> 331943.203 NVMEM 2(Report Storage) 1 per site x Hnn:FLOW COLLECT 1 Hose Blockage Problem <br /> 330020-515 Vapor Pressure Sensor Kit 1 per site X ISD VP STATUS 1 Vapor Processor Problem <br /> 330160-xxx ISD Software Enhancement 1 per site x ISD VP PRESSURE 1 Vapor Processor Problem <br /> Module(SEM) <br /> PMC Components with VST <br /> Part Number Description Quantity <br /> 847490-315 PMC Port Controller for VST 1 per site <br /> 331943-203 NVMEM 2(Report Storage) 1 per site <br /> 330020-515 Vapor Pressure Sensor Kit 1 per site <br /> Typical ISD Installation <br /> Dispenser hydraulics cabinet <br /> I <br /> ISD Pressure Sensor <br /> (in 1 dispenser only)._f <br /> Cable <br /> r - ---- - -_---------- _ <br /> l INLET ressure sensing port Vapor return line <br /> \ from dispenser <br /> .�f �� ISD Flow Meter <br /> j <br /> in <br /> anywhere <br /> \ In vapor Ilne above Junction box <br /> / shear valve) Cable (customer <br /> Arrow must t/4"OD i supplied) <br /> point down rigid tubing <br /> I�• I as required <br /> ,Seal an <br /> y I Pit to �! Vapor return line (customer <br /> OUTLET —'dram t/4" •-'I supplied) <br /> \ Fbw meter 9n0 view per nt <br /> Shear valve <br /> -� <br /> horizontal <br /> __ �r <br /> uV �`Conduit to � <br /> Top of pedestal island I ( TLS Console <br /> _ I <br /> tD <br /> l , � <br /> o as QQe(7a ' <br /> L> 0 0 0 0 0 OQ A test port is required for <br /> �C�-'0�� O.4 introducing liquid during Flow Meter and Pressure <br /> 0 jj'Q TP-201.4 dynamic Sensor wiring may share <br /> a 0 0 backpressure test. the same conduit to console <br /> 6:Z0n�� C, <br /> 0 2"or 3"camnwn main vapor return line <br /> �o <br /> p op I <br /> O (�� Q O OQ Dispenser sump too <br /> -..... [] <br /> For more information on Veeder-Root's In-Station Diagnostics, please visit www.veeder.com/page/EVR_Solutions <br /> �fc. <br /> VEEDER-ROOT To learn more,contact us at 1-888-561-7942, or visit www.veeder.com <br /> 125 Powder Forest Drive,P.O.Box 2003,Simsbury,CT 06070 USA <br /> 02008 Veeder-Root Company P/N 0576047-065 Rev.0 Printed in USA <br />