Laserfiche WebLink
FROM ' • • <br /> Discriminating Dispenser Pan • <br /> Containment • Sensors <br /> The housing is constructed of polyester; the sensing <br /> element is a combination of conductive elastomer and <br /> float-switch technologies. The sensors can be reused after <br /> an alarm condition is sensed, without degradation to the <br /> sensing materials. Remove and clean the sensor,then <br /> reinstall for the same reliable sensing as when it was new. <br /> The Discriminating Dispenser Pan and Containment <br /> Sump Sensors are easily installed using Veeder-Root's <br /> Universal Sensor Mounting Kit. <br /> xµ5 The Dispenser Pan and Containment Sump Sensors are <br /> warranted to be free from material defects for a period of <br /> one year from the date of installation or 15 months from the <br /> date of invoice. <br /> ► Low cost solution for total information Detection Capabilities <br /> management ► Sensor Alarm Conditions: <br /> ► Float switches determine presence of fluid, • Fuel at any height on the sensor even when <br /> floating on other liquid, triggers a Fuel Alarm. <br /> and trigger alarms at low level and high level • Liquid Warning is triggered when liquid reaches <br /> "trip"points. 1.0"high on both Dispenser Pan and Contain- <br /> No- Conductive elastomer differentiates between ment Sump Sensors. <br /> hydrocarbons and other liquids, and alarms • High Liquid Alarm is triggered when liquid <br /> when hydrocarbon is detected at any point reaches 8.0"on Dispenser Pan Sensor or 10"on <br /> on the sensor. Containment Sump Sensors. <br /> ►Accurate, reliable and reusable even ► Sensor should be tested in liquid at least once a <br /> after exposure to heavy concentrations year or as required by local codes. <br /> of hydrocarbons. Operating Capabilities <br /> ► Long-life, durable construction. ► Operating Temperature Range: -0°C to+70°C. <br /> Veeder-Root's Discriminating Dispenser Pan and Contain- <br /> ► Storage Temperature Range: -40°C to+70°C. <br /> ment Sump Sensors quickly and accurately detect the ► Cable Length:6 feet. <br /> presence of hydrocarbons or fluids, and differentiate be- ► Dispenser Pan Sensor Dimensions: 11.53"high, <br /> tween the two, in their respective locations. 2.13"diameter. <br /> Alarm conditions—Fuel, Liquid Warning, High Liquid Alarm, ► Containment Sump Sensor Dimensions:22.03" <br /> Sensor Out—detected by either sensor are indicated by high, 2.13"diameter. <br /> an audible alarm, a displayed message, and a printed mes- <br /> sage on the TLS-35OR or TLS-350.They are also recorded ► Withstand removal and replacement from sensing <br /> as part of the TLS-350R or TLS-350 Alarm History Report. environment without sensor damage. <br />