Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
440
>
2300 - Underground Storage Tank Program
>
PR0231055
>
INSTALL_2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/27/2019 3:44:46 PM
Creation date
11/27/2019 9:04:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2000
RECORD_ID
PR0231055
PE
2361
FACILITY_ID
FA0002321
FACILITY_NAME
Delta arco
STREET_NUMBER
440
Direction
W
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
16503003
CURRENT_STATUS
01
SITE_LOCATION
440 W DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
279
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- - 3' SECONDARY CONTAINMENT <br /> g 2' VENT 1a ,Ay �O _ _. /�___ _- 2" PRODUCT LINE <br /> CO <br /> /�7 <br /> F��10 So <br /> --RED JACKER FLEX CONNECTOR pum <br /> LEX C1 J�� RV I N IX AJSO IA I CJr �IV <br /> 2' VENT MANIFOLD - 2„ N P . FRQ TURBINEJPETRO <br /> PLUG <br /> --VALVE <br /> S1 TEE MUST BE n nn (� <br /> N THIS POSITIONUNION A R C H T E C T STO ELIMINATE `FUEL LOSS WHENOPENINGS P L A IV IV E RS <br /> ACCESS TOYTPNK &64Pp UPLUG SED. IS TO BE� ' VALVE —. rF.EVALVE --2" TEE W/PLUG <br /> TfOR NNRE <br /> UW=UNVENT ONE ' 3633 SEAPORT BLVD., SUITE C <br /> A. Q : 'os suMP / 7?, / sue PUMPyyEST SACRAMENTO. CA: 95691 <br /> VALV3" VAPOR RETURN LINE <br /> "r, <br /> TANK OR LONLY.T((Omrr ON DIESEL TANK),REFER TO PIDING PIAN FOR ACTUAL PFiCPE: (916) 373-9700 <br /> EXTRACTOR ASSEMBLY3" VR S CONFIGURATION & SIZE. ` FOR ,EM FAX: (918) 371-0200 <br /> NOTE: <br /> E-MAIL' Icasna.net <br /> s PIPES MUST EXIT PERPENDICULAR TO SUMP WALL <br /> " NEVER COVER UNUSED BUNGS W/ PIPE OR CONDUIT <br /> (Q1999 LEX COFFROTH & ASSOCIATES <br /> PLANS MAY NOT BE REVISED, COPIED, OR <br /> SUMP PLAN REUSED WITHOUT PRIOR WRITTEN PERMISSION <br /> 17 VAPOR MANIFOLD 13 AXONOMETRIC VIEW OF MANIFOLD 9 AXONOMETRIC VIEW OF MANIFOLD _SIDE _VIEW OF SUMP PLAN (GASOLINE/DIESEL TANK) OF LEX COFFROTH, ARCHITECT. <br /> SCALE: NT.S.. SCALE: N.T.S. SCALE: N.T.S. SCALE: 1" = 1'-0" � SCALE: 1/2" - l'-O" <br /> �NS9.D ARC <br /> H/r <br /> GENERAL NOTES: (* � G-13842 6 * <br /> - III �✓ I 1 I N�sa �� <br /> ALL TANK AND UNE INSTALLATIONS SHALL BE PERFORMED 1. FULL SYSTEMS PRECISION TANK & UNE TESTING _ _ <br /> TO BE ARRANGED BY FUEL SUBCONTRACTOR (NOTIFY — F <br /> BY LICENSED US MATE C-36, GENERAL AOR GENERAL B — Ir I — pF CALVE <br /> WITH HAZARDOUS MATERIALS GER➢FlCA1E CONTRACTOR GENERAL CONTRACTOR REPRESENTATIVE 2 WEEKS _ � Z � � —_ 36' DIA MANHOLE <br /> THESE PLANS ARE DOGRAMATIC IN NATURE AND ARE NOT IN ADVANCE). �'j �-- <br /> INTENDED TOBEEXACT REPRESENTATION OF THE FINAL 2, SUMP BOXES & TUR8INE SUMPS ARE TO BE 1 I I ,,,///���3 #4 BARS <br /> PRODUCT, THESE PLANS SHALL BE USED BY THE - WATER TESTED AS FOLLOWS: I ` ` �6' LONG TYP. CONTRACTOR: <br /> CONTRACTOR AS ANO ONLY, CONTRACTOR SHALL BE n IN1 4 TYP <br /> RESPONS18LE FOR THE COMPLETE INSTALLATION OF TANKS, 1. FILL WATER TO HIGHEST PENETRATION. ��.��� ��� ���f NCQ <br /> PIPES, AND ALL EQUIPMENT ASSOCIATED WITH SCOPE \ I I 1c,R.R�/ CONSTRUCTION'}�` `/�� 1 <br /> OF WORK. 3. ON <br /> AFTER PRESSURE TESTS ARE COMPLETED / ,I 'I� ` 4/®NI I LNVRI®N <br /> ON ALL THE LINES, PRESSURE MAY BE REDUCED <br /> ' TO A MINIMUM OF 20 PSI AND MUST BE MWNTAINED �I '^1 <br /> UNTIL ALL CONCRETE/ASPHALT SURFACES HAVE BEEN I ' ` !' 1 6" m'• INC. <br /> COMPLETED. pp C <br /> ` � 674EMS DLAG. <br /> LONG TYP <br /> 3633 SEAPORT BLVD. <br /> III ^ III WEST SACRAMENTO, CA 95691 <br /> Phone: 916-372-1985 <br /> - O- <br /> TANK LEVEL MONITOR <br /> Fax: 916-372-0911 <br /> VENT/VAPOR— O ' O TURBIN VAPOR RECOVERY O RLI, DEVELOPER: <br /> SUB-PUMP <br /> r"„�_M.H. REBAR DETAIL <br /> 1/2" = 1'-Q' <br /> REBAR 0 SUBPUMP . <br /> SEE l^ <br /> Maeerroslaluminumorros[iron C f m` A _ „-{ <br /> Mounhnyy nng Dwagard®tooled test iron <br /> Bellows:hlghdeemilypalyelhylene <br /> FOR DRY TANK HOLE }, Base:Duratull 16 <br /> 9' CONC. TANK k EXTRACTOR ASSEMBLY - ASPHALT OR CONC. YARD (lamps:sloinlesssleet - REVISIONS <br /> PRAIM VALVE <br /> SLAB W/ t REBAR FOR VENT k 4" PIPE SEE CIVIL SITE PLAN AT 24" O.C. EACH WAY CAP - VAPOR RISER (CMH ON DIESEL) Seals:bunatl cottons 1 DESCRIPTION I DATE '. <br /> 4" RISER & 36' DIA CONTAINMENT MANHOLE 3 I � D NO. s - .-.. L_-- -, <br /> CONC SHALL EXTEND A MINIMUM - .TANK LEVEL MONITOR i TL2 Ordering <br /> fa6 Ulr J QI_ <br /> CITY PLAN CHECK L9/14/99 <br /> OF 2'-0" BEYOND THE ENDS AND SLOPE CONI, DOWN 1 1/2' <br /> SIDES OF THE TANKS (SEE SITE SUB PUMP -. . . I FILL CAP ADAPTOR a .(over Lbs. 1:g. - -- <br /> PLAN FOR ACTUAL TANK SLAB SIZE). S .- - FROM MANHOLES, TYP. __ --- <br /> r LO-2000 LEAH DETECTOR 1X00 5 10 (asl ATummmn 39 11 <br /> A <br /> i I 38" DIA MANHOLE 1 "� I ANNULAR SPACE MONITOR RL2100 5 19 (aSI�ar�S2 24 B <br /> 2' MIN. 1 2" p.V..C, FOR PR 12115 IS 56_ Cast Aluminuld 4Stl <br /> • � 16' DIA MANHOLE -� <br /> --- - .-v OBE IG2115 IS Sd (asl Iron 60 i OPW 1,2100, 5 Gallon <br /> Replace enl Parts <br /> m <br /> _. SKIRT EXTENSION <br /> .;I & Ei0 SEE NLN. 2' FORA - -... PVC SCR. SOW/ I - lam 0mm YoTva Rtl j <br /> r <br /> MIN. 2" FOAM ----"' I FIBERGLASS SUMP I <br /> CONTAINMENT SUMP <br /> 121A( _46 <br /> T mmum(ove w e�al <br /> 1 1 / BRINE FILLED ANNULAR ( I L - I 1 21(( (osl Iron(ovepw / <br /> i I I I 18" MIN. RISER HEIGHT e 42" CONTAINMENT SUMP-�\ III ^ I 1 1 III 712229M F(arer Seal -- ,R - <br /> 0 o III +� 42 CONTAINMENT SUMP ''—� <br /> SPARE III I TANK LEVEL MONITOR � I I ' Ij - Dimensions v,7 <br /> FIBERGLASS ALL SUMPS _ ll -I 62100 1211$ <br /> TO TANK COLLARS- TYP. -Flrl7i In '41 In 4 <br /> I— _ - -- A 16 �. 1 <br /> — — — UQUID SENSING PROBE — — — — — — — — — — - — — -- — -_� B 14 ,.36 22' -.- S6^ DRAWINGS D FOR: <br /> D PREPARE <br /> 2% 24" FLEX CONNECTOR I i I l i PEABACGRAVEL �* ( 1S1F . 3 19P _ 9 / FILLNER <br /> FILL <br /> (O ITVAPOR/VENTDIESEL <br /> SERETURN PIPING I - _Q --- D 188 47 23Yr".., S9 / FILL SPILLTANK AND LINE <br /> 1 i I I (OMIT ON DIESEL TANK) i I OPW 6150 OVER I 1 18' MINI -. - <br /> FILLL�PREVENTION 'CONTAINMENT MANHOLE ST4CKTON <br /> FILTER FABRIC ` - I - I, CONIC. TANK SLAB FlLL CAP & ADAPTOR <br /> (IF REOIRED) <br /> LIQUID SENSING (. <br /> CORNER OF LINCOLN STREET AND <br /> i PROBE WHEN WEST CHARTER WAY <br /> ANNULAR SPACE �I STOCKTON. CA ' <br /> i IS DRY THIS DIMENSION IS <br /> DEPENDING ON UD - <br /> EXTENSION MANUF'G <br /> x TOP OF <br /> FILL ADAPTER SHEET TITLE: - <br /> �..� <br /> FOAM ---- 4" RISER PIPE <br /> I <br /> _ _ � TANK ' & LINE <br /> J ( GT`HBE <br /> — _ __ �_ _ �. _I _ _. ..— ( _ OLk�ERMINED BY I. <br /> �. -.- — .— — -.-" - _ _ — g g /� <br /> DEFLECTOR PLATE <br /> SLOPETANKDOWN 1-1/2" TO 2' TOWARDS RLL. (SPOT TANKS SHALL BE LEVEL) I -. I_ SPE IFIICATIONS .REDUCING CONTRACTOR IN FlELD). DETAILS <br /> UNDER ALL, _... _.... _. — I _ <br /> TANK BUNGS , PEA GRAVEL BED <br /> RING ' <br /> I { � -ITL— � I ;. I I � I , I <br /> FIBERGLASS SUMP <br /> FORNOTDETAILOF SPILL CONTAINERS <br /> I DATE. 8/27/99 SHEET N0. <br /> 171, <br /> DRAIN VALVE SEE ABOVE, PROJ.1d: 99-0804 <br /> -- <br /> . .. . SCALE: AS SHOWN TLA <br /> . 4 1 <br /> TYPICAL TANK, <br /> ELEVATION ON / SECTION . 4 ` <br /> RISER DETAIL DRAWN BY: RC <br /> (AUTO GASOUNE /DIESEL) SCALE: 1/2"=1 O" <br /> - <br /> SCALE: 1'. <br /> CHECKED BY: WA ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.