INSTALL_2000
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
440
>
2300 - Underground Storage Tank Program
>
PR0231055
>
INSTALL_2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/27/2019 3:44:46 PM
Creation date
11/27/2019 9:04:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2000
RECORD_ID
PR0231055
PE
2361
FACILITY_ID
FA0002321
FACILITY_NAME
Delta arco
STREET_NUMBER
440
Direction
W
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
16503003
CURRENT_STATUS
01
SITE_LOCATION
440 W DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
279
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2.2.3 Pipe assembly system tested after the product two halves with flanges as shown <br /> The containment pipe must be piping system has been tested. in Figure 2.2.3. <br /> positioned over the product pipe Note: Do not leave rocks, pea <br /> gravelsandor other debris in the Fittings are assembled with 1/4- <br /> , , <br /> before bonding the product pipe. inch 20NC hex head bolts or 1/4- <br /> Pre-installation of the secondary containment piping system. inch 20NC carriage bolts along <br /> containment pipe (only) is best Typically, the length of the con- with Smith Fiberglass Products <br /> accomplished at the same time the tainment pipe is determined from adhesive (mixed with filler). Note: <br /> product pipe is dry fitted together. the following formula, using Table Secondary containment fittings are <br /> This will speed up installation and 2.2.1 and Figure 2.2.2 as a supplied without hardware. See <br /> prevent unnecessary delays. reference: Table 2.2.2 for bolt information. <br /> Where possible,temporarily place L = (OAL of Product Piping) - B The bonding surfaces of the con- <br /> containment fitting halves around Note: When terminating with a tainment fittings are supplied from <br /> the product fittings. This measure termination concentric reducer, the factory pre-sanded.Two-piece <br /> will help prevent foreign material use the "C" dimension instead of secondary containment fittings must <br /> from entering the containment the "B" dimension in Table 2.2.1. be joined using a greater amount <br /> pipe. See Figure 2.2.3. of adhesive than is necessary for <br /> The containment fittings should be 2.2.4 Fitting assembly joining bell and spigot joints of <br /> installed and the containment All containment fittings consist of product piping. See Figure 2.2.4 <br /> TABLE 2.2.1 TABLE 2.2.2 <br /> DETERMINING LENGTH OF CONTAINMENT PIPE BOLT INFORMATION(NUMBER OF BOLT HOLES) <br /> Product Termination <br /> Pipe Size B C Size 90° 45° Concentric <br /> (in.) (mm) (in.) (mm) (in.) (mm) (in.) (mm) Elbow Tee Elbow Reducer Coupling <br /> 2 51 3 76 6 152 3 76 10 11 9 6 10 <br /> 3 76 3-1/2 89 6-1/2 165 4 102 10 11 9 6 10 <br /> 4 102 3-1/2 89 7-1/2 191 6 152 10 11 9 6 10 <br /> Example: If 2" (51 mm) product pipe is 20 ft., 6 in. Hex head bolts are 1/4-i nch 20NC x 1.0 inches long with two 1/4-inch <br /> (6m, 248 mm) long,cut the containment pipe 20 ft.,3 in. washers per hole.Carriage bolts are 1/4-inch 20 NC x 1.0 inches long <br /> (6m, 172 mm) long. with one 1/4-inch washer per hole.Standard nuts are 1/4-inch 20NC. <br /> Containment <br /> Pipe <br /> T Adhesive 1to <br /> Apply pi Product both halves <br /> and to pipe <br /> Pipe Q• 1/16"minimum thickness. <br /> L OAL <br /> 1 O O Box wrench or <br /> --LL impact wrench <br /> O / <br /> Figure 2.2.2 <br /> Q I I <br /> I t <br /> Box wrench <br /> \� Make sure pipe fits <br /> snugly into fitting socket <br /> eLay system and that no gap exists. <br /> ry joints. <br /> Figure 2.2.3 Figure 2.2.4 <br /> 25 <br />