Laserfiche WebLink
2.2.3 Pipe assembly system tested after the product two halves with flanges as shown <br /> The containment pipe must be piping system has been tested. in Figure 2.2.3. <br /> positioned over the product pipe Note: Do not leave rocks, pea <br /> gravelsandor other debris in the Fittings are assembled with 1/4- <br /> , , <br /> before bonding the product pipe. inch 20NC hex head bolts or 1/4- <br /> Pre-installation of the secondary containment piping system. inch 20NC carriage bolts along <br /> containment pipe (only) is best Typically, the length of the con- with Smith Fiberglass Products <br /> accomplished at the same time the tainment pipe is determined from adhesive (mixed with filler). Note: <br /> product pipe is dry fitted together. the following formula, using Table Secondary containment fittings are <br /> This will speed up installation and 2.2.1 and Figure 2.2.2 as a supplied without hardware. See <br /> prevent unnecessary delays. reference: Table 2.2.2 for bolt information. <br /> Where possible,temporarily place L = (OAL of Product Piping) - B The bonding surfaces of the con- <br /> containment fitting halves around Note: When terminating with a tainment fittings are supplied from <br /> the product fittings. This measure termination concentric reducer, the factory pre-sanded.Two-piece <br /> will help prevent foreign material use the "C" dimension instead of secondary containment fittings must <br /> from entering the containment the "B" dimension in Table 2.2.1. be joined using a greater amount <br /> pipe. See Figure 2.2.3. of adhesive than is necessary for <br /> The containment fittings should be 2.2.4 Fitting assembly joining bell and spigot joints of <br /> installed and the containment All containment fittings consist of product piping. See Figure 2.2.4 <br /> TABLE 2.2.1 TABLE 2.2.2 <br /> DETERMINING LENGTH OF CONTAINMENT PIPE BOLT INFORMATION(NUMBER OF BOLT HOLES) <br /> Product Termination <br /> Pipe Size B C Size 90° 45° Concentric <br /> (in.) (mm) (in.) (mm) (in.) (mm) (in.) (mm) Elbow Tee Elbow Reducer Coupling <br /> 2 51 3 76 6 152 3 76 10 11 9 6 10 <br /> 3 76 3-1/2 89 6-1/2 165 4 102 10 11 9 6 10 <br /> 4 102 3-1/2 89 7-1/2 191 6 152 10 11 9 6 10 <br /> Example: If 2" (51 mm) product pipe is 20 ft., 6 in. Hex head bolts are 1/4-i nch 20NC x 1.0 inches long with two 1/4-inch <br /> (6m, 248 mm) long,cut the containment pipe 20 ft.,3 in. washers per hole.Carriage bolts are 1/4-inch 20 NC x 1.0 inches long <br /> (6m, 172 mm) long. with one 1/4-inch washer per hole.Standard nuts are 1/4-inch 20NC. <br /> Containment <br /> Pipe <br /> T Adhesive 1to <br /> Apply pi Product both halves <br /> and to pipe <br /> Pipe Q• 1/16"minimum thickness. <br /> L OAL <br /> 1 O O Box wrench or <br /> --LL impact wrench <br /> O / <br /> Figure 2.2.2 <br /> Q I I <br /> I t <br /> Box wrench <br /> \� Make sure pipe fits <br /> snugly into fitting socket <br /> eLay system and that no gap exists. <br /> ry joints. <br /> Figure 2.2.3 Figure 2.2.4 <br /> 25 <br />