C A M B R I A Ms. Lori Duncan <br /> November 18,2005 <br /> Chemical Analyses: Selected soil samples from the well borings will be analyzed for TPHg, <br /> BTEX, fuel oxygenates (MTBE, ethyl tertiary butyl ether, DIPE, tertiary amyl methyl ether, and <br /> TBA), 1,2-DCA and ethylene dibromide (EDB) by EPA Method 8260B. Groundwater samples <br /> from wells VEW-3 through VEW-6 will be also analyzed for TPHg, BTEX, fuel oxygenates, 1,2- <br /> DCA, and EDB. Groundwater samples from the existing wells (MW-1 through MW-13 and <br /> VEW-2)will be analyzed per the existing protocol. <br /> Wellhead Survey Activities: Following monitoring well installation, a licensed surveyor will <br /> survey wellhead elevations relative to mean sea level and the wells' latitude and longitude. <br /> © Report Preparation: Following the receipt of analytical results from the laboratory, Cambria will <br /> prepare a written report, which will include field procedures,laboratory results, and boring logs. <br /> Cambria will perform the scope of work described in this work plan under the supervision of a <br /> professional geologist or engineer. <br /> Schedule <br /> Upon receiving work plan approval from SJCEHD, Cambria will schedule the field work and <br /> submit a permit application to SJCEHD. <br /> REMEDIAL ACTION PLAN <br /> DPE System <br /> System Design: The proposed DPE system design includes extraction from existing wells VEW-1 <br /> and VEW-2 and proposed wells VEW-3 through VEW-7. A Solleco trailer-mounted electric <br /> catalytic oxidizer (Solleco unit) will be used as the extraction and vapor treatment device. <br /> Specifically, the Solleco unit will be an ECAT (LR) Series Oxidizer. Solleco unit technical <br /> specifications are provided as Attachment C. The Solleco unit is equipped with a liquid-ring <br /> pump driven by a 20-horsepower motor. This pump and motor package can generate a vacuum <br /> up to 26 inches of mercury and an air flow rate up to 300 cubic feet per minute. A throttle valve <br /> will control the applied vacuum and vapor extraction flow rate. The Solleco unit is equipped with <br /> auto-dilution and manual dilution valves for additional vacuum and flow control, as well as to <br /> maintain oxidizer temperatures within the specified range. <br /> Downwell stingers will be set at target elevations at each extraction point. Extracted groundwater <br /> and soil vapors will be conveyed through a suction hose passing through an air-tight well seal. <br /> The suction hoses will extend from the extraction points to the remediation compound where they <br /> will be manifolded into a common header. From the header, the extracted groundwater and soil <br /> 7 <br />