Laserfiche WebLink
. CAMBRIA <br /> MW-10, and MW-11, located south of the subject site, are primarily caused by the presence of <br /> chlorinated compounds in the groundwater Benzene was detected in wells MW-2 through <br /> MW4, MW-6, and MW-7 at concentrations ranging from 0 52 to 3,800 ppb MTBE and DIPE <br /> were detected in well MW-4 at concentrations of 5 9 and 36 ppb, respectively TBA was <br /> detected in well MW-10 at 120 ppb No other fuel oxygenates were detected in wells sampled <br /> this quarter <br /> Groundwater chemical analytical data for CPT borings SB-5 and SB-6 are summarized in <br /> Table 3 and TPHg, benzene, and MTBE results are presented on Figure 3 The laboratory <br /> analytical report for SB-5 and SB-6 is presented in Appendix D Groundwater chemical <br /> analytical data for the monitoring wells are summarized in Blaine's Well Concentrations table <br /> (included in Appendix D) and Table 4 and benzene and MTBE results are presented on Figure 3 <br /> The laboratory analytical report for the monitoring wells is also presented in Appendix D <br /> SENSITIVE RECEPTOR SURVEY <br /> Cambria reviewed California Department of Water Resources (DWR) records to identify water- <br /> producing wells within a 2,000-foot radius of the subject site and identified surface water bodies <br /> within a 2,000-foot radius of the site by reviewing maps Table 5 summarizes the well <br /> information, and Figure 1 shows the area encompassed by the survey, the results of the well <br /> survey, and the surface water bodies <br /> Water Well Survey The DWR records identified four wells within the study area The wells <br /> were installed between 1951 and 1978 Three of the wells were installed for domestic use and <br /> one was installed for municipal use The closest well to the subject site is a domestic well <br /> located approximately 450 feet northeast of the site A second domestic well is located 850 feet <br /> northeast of the site The municipal well is located approximately 2,000 feet northwest of the <br /> site, and the remaining domestic well is located approximately 2,000 feet southwest of the site <br /> Available well construction information is summarized on Table 5 and the approximate well <br /> locations are plotted on Figure 1 <br /> Surface Water Bodies Cambria reviewed the United States Geological Survey 7 5 minute <br /> quadiangle indps for Stockton, California anti California State Automobile Association maps to <br /> evaluate the presence of surface water bodies within the survey area No surface water bodies <br /> were identified within the study area <br /> 0854 7 <br />