ARCHIVED REPORTS_XR0006819
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6131
>
3500 - Local Oversight Program
>
PR0545003
>
ARCHIVED REPORTS_XR0006819
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/27/2019 11:48:20 AM
Creation date
11/27/2019 11:09:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0006819
RECORD_ID
PR0545003
PE
3526
FACILITY_ID
FA0002324
FACILITY_NAME
Pacific Service Station
STREET_NUMBER
6131
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
09746418
CURRENT_STATUS
02
SITE_LOCATION
6131 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
201
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
dispenser islands TPH-G concentrations were detected in soil samples ranging from ND to 19,000 <br /> 1 ppm Benzene concentrations were detected in soils ranging from ND to 280 ppm Monitoring wells <br /> MW-1 through MW-3 were installed to evaluate ground water quality Soils from these well borings <br /> contained TPH-G ranging from ND to 28 ppm and benzene ranging from ND to 0 38 ppm Vapor <br /> extraction well VEW-2 soils contained TPH-G ranging from 2,800 to 12,000 ppm and benzene <br /> ranging from 18 to 110 ppm Soil analytical results are presented in Table 1 - Analytical Results <br /> Soil (Fugro West, Inc , December 1995) In late 1991 and early 1992, a 75-day vapor extraction <br /> feasibility test was performed at the subject site using wells VEW-1, VEW-2, and MW-3 Wells <br /> VEW-1 and VEW-2 were tested to evaluate their feasibility in addressing petroleum hydrocarbons <br /> detected below the former USTs location Well MW-3 was selected based on previously detected <br /> separate-phase hydrocarbons (SPH) in this well However, SPH has not been detected in well MW-3 <br /> since August 1993 <br /> I <br /> In September 1995, four geoprobes (GE01 through GE04), were driven to depths up to 56 fbg and <br /> sampled Soil samples obtained from these probes contained TPH-G ranging from ND to 7,000 ppm <br /> and benzene ranging from ND to 10 ppm These soil data were obtained from samples collected <br /> from depths ranging from 16 to 49 fbg <br /> It appears that petroleum hydrocarbons in soil are primarily contained within a limited area beneath <br />• the former UST complex and along portions of the former product piping (3 fbg) Petroleum <br /> hydrocarbons were not detected in unsaturated soils analyzed from Borings MW-3, B-6, GE01, and <br /> GE04, located down-gradient from the former UST location Petroleum hydrocarbons were not <br /> detected in unsaturated soils analyzed from up-gradient wells MW-1 and MW-2, Borings B-2, B-5, <br /> and GE03 Petroleum hydrocarbons were also not detected in unsaturated soils analyzed from the <br /> new USTs location, Borings B-1, B-9, B-10, B-1 I, B-12, B-13 and B-14 <br /> Based on these data and the quarterly ground water monitoring reports, the SJCPHS requested that an <br /> additional soil and ground water investigation be performed The results of this investigation are <br /> presented below <br /> FIELD PROCEDURES <br /> is <br /> Exploratory Soil Borings Eight exploratory soil borings were drilled and sampled using hollow- <br /> stem auger drilling equipment Four soil borings (SB-1 through SB-4) were drilled on July 2, 1997 for <br /> the purpose of delineating the vertical extent of petroleum hydrocarbons in on-site soils Four soil <br /> borings (MW-4 through MW-7) were drilled between September 16, and 18, 1997 for the purpose of <br /> delineating the extent of petroleum hydrocarbons in on/off-site soils and ground water After <br /> drilling, Borings MW-4 through MW-7 were converted to ground water monitoring wells The boring <br /> and well locations are shown on Plates 2 and 3 <br /> 374 2 <br />