m ' <br /> cme KEY TO RESULT FLAGS <br /> 0 <br /> * RPD between sample duplicates exceeds 30t <br /> *M RPD between sample duplicates or MS/MSD exceeds 20: <br /> + Correlation coefficient for the Method of Standard Additions is less than 0 995 <br /> c Sample result is less than reported value. <br /> S-I Value is between Method Detection Limit and Reporting Limit <br /> B-0 Analyte found in blank and sample <br /> C The result confirmed by secondary column or GC/MS analysis. <br /> CNA Cr+6 not analyzed; Total Chromium concentration below Cr+6 regulatory level <br /> COMP Sample composited by equal volume prior to analysis <br /> D- The result has an atypical pattern for Diesel analysis <br /> D1 The result for Diesel is an unknown hydrocarbon which consists of a single peak <br /> DH The result appears to be a heavier hydrocarbon than Diesel <br /> DL The result appears to be a lighter hydrocarbon than Diesel <br /> DR Elevated Reporting Limit due to Matrix <br /> DS Surrogate diluted out of range <br /> DX The result for Diesel is an unknown hydrocarbon which consists of several peaks <br /> FA Compound quantitated at a 2X dilution factor <br /> FB Compound quantitated at a 5X dilution factor <br /> FC Compound quantitated at a IOX dilution factor <br /> FD Compound quantitated at a 20X dilution factor <br /> FE Compound quantitated at a SOX dilution factor <br /> FF Compound quantitated at a 1OOX dilution factor <br /> FG Compound quantitated at a 20OX dilution factor <br />• FH Compound quantitated at a S00X dilution factor <br /> FI Compound quantitated at a IOOOX dilution factor <br /> FJ Compound quantitated at a greater than 1000x dilution factor <br /> FK Compound quantitated at a 25X dilution factor <br /> FL Compound quantitated at a 25OX dilution factor <br /> G- The result has an atypical pattern for Gasoline <br /> G1 The result for Gasoline is an unknown hydrocarbon which consists of a single peak <br /> GH The result appears to be a heavier hydrocarbon than Gasoline <br /> GL The result appears to be a lighter hydrocarbon than Gasoline. <br /> GX The result for Gasoline is an unknown hydrocarbon which consists of several peaks <br /> HX Peaks detected within the quantitation range do not match standard used. <br /> J Value is estimated <br /> MI Matrix Interference Suspected. <br /> MSA Value determined by Method of Standard Additions <br /> MSA* Value obtained by Method of Standard Additions, Correlation coefficient is c0.995 <br /> NI1 Sample spikes outside of QC limits, matrix interference suspected. <br /> NI2 Sample concentration is greater than 4X the spiked value; the spiked value is <br /> considered insignificant. <br /> U13 : Matrix Spike values exceed established QC limits, post digestion spike is in <br /> control. <br /> P7 : pH of sample > 2; sample analyzed past 7 days <br /> RSC : Refer 'to subcontract laboratory report for QC data. <br /> S2 : Matrix interference confirmed by repeat analysis <br /> SCN Thiocyanate not analyzed separately; total value is below the Reporting Limit for <br /> Free Cyanide. <br /> UMDL . Undetected at the Method Detection Limit <br />