Laserfiche WebLink
r� <br /> EI1_wcp <br /> I Sam le Descri tion <br /> See the attached Sample Description Information. <br /> The samples were received under chain-of-custody. <br /> II Anal sis Re gest <br /> The following analytical tests were requested. <br /> Lab ID An alysis Descriyiion <br /> 060170-1 thru 5 Volatile Organics <br /> Total Petroleum Hydrocarbons (Gasoline) <br /> -3 thru 5 Total Petroleum Hydrocarbons (Triregional) <br /> -1 thru 5 Lead <br /> UL_Quality ontrol <br /> A. Proiect Saecific QC-- No project specific QC (i.e., spikes and/or <br /> duplicates) was requested. <br /> B. Method Blank Results_ A method blank is a laboratory-generated <br /> sample which assesses the degree to which laboratory operations <br /> and procedures cause false-positive analytical results for your <br /> samples. <br /> n,; trget witha <br /> ayour samplesers at thewere <br /> reporting limitthe <br /> levelsmethod <br /> notedblanks <br /> onassociated <br /> the <br /> Method Blank Report. <br /> Repetitions of method blanks (with identical QC Lot No.s and Run <br /> No.$) have been reported but do not indicate unique <br /> determinations. <br /> C. Laboratory Control Sam les - 1•he LCS Pra ram <br /> Du licate Control Sam les. A DCS is a well-characterized matrix <br /> (blank water, sand or celite) which is spiked with certain target <br /> parameters and analyzed at approximately 10% of the sample load in <br /> order to establish method-specific control limits. The DCS <br /> results associated with your samples are on the attached Duplicate <br /> Control Sample Report. <br />