My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0007886
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEBER
>
1325
>
3500 - Local Oversight Program
>
PR0545007
>
ARCHIVED REPORTS_XR0007886
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2019 2:39:06 PM
Creation date
12/5/2019 1:42:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0007886
RECORD_ID
PR0545007
PE
3528
FACILITY_ID
FA0025604
FACILITY_NAME
CATELLUS DEVELOPMENT PROPERTY
STREET_NUMBER
1325
Direction
W
STREET_NAME
WEBER
STREET_TYPE
AVE
City
STOCKTON
Zip
95203
CURRENT_STATUS
01
SITE_LOCATION
1325 W WEBER AVE
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
169
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INCHCAPE TESTING SERVICES, SAN JOSE LABORATORIES <br /> REPORT DESCRIPTION - INORGANICS <br /> Analytical Data Report(ADR) <br /> ' The ADR contains tabulated results for inorganic analytes All field samples, QC samples and blanks were prepared and analyzed <br /> according to procedures in the following references <br /> — "Test Methods for Evaluating Solid Waste,"SW-846,EPA,3rd Edition,1994 <br /> ' "Methods for Chemical Analysts of Water and Wastes,"EPA,3rd Edition,I983 <br /> CCR Title 22,Section 66261,Appendix 11,California Waste Extraction Test <br /> CCR Title 22 Section 66261,Appendix M,Organic Lead <br /> — "Standard Methods for the Examination of Water and Wastewater,"APHA,AW WA,WEF,' 18th Edition, 1992_ USEPA Contract Laboratory Program Statement of Work for Inorganic Analyses,ILM02 1,IL th E ti II 199 0, 1991-1995 <br /> Matrix Spike Report(MSR) <br /> The MSR summarizes the percent recovery and relative percent difference information for matrix spikes and matrix spike duplicates This <br /> ' Information is a statement of both accuracy and precision MSRs may not be provided with all analytical reports <br /> Laboratory Control Sample Report(LCSR) <br /> ' The LCSR summarizes percent recovery information for laboratory control spikes on reagent water or soil This information is a statement <br /> of performance for the method,i e,the samples are properly prepared and analyzed according to the applicable methods <br /> Method Blank Report(MBR) <br /> The MBR summarizes quality control information for rex <br /> the method blank should be below the method r eportmg lgents used in preparing samples The absolute value of each analyte measured in <br /> imit(PQL)for that analyte <br /> Post Digestion Spike Report(PDSR) <br /> The PDSR summarizes percent recovery information for post digestion spikes A post digestion spike is performed for a particular analyte <br /> if the matrix spike recovery is ou#sde of estabhshed controI limits Any percent recovery for a post digestion spike outside of established <br /> limits for an analyte indicates probable matrix effectsand interferences for that analyte <br /> Qualifiers(Q) <br /> ITS-SI uses several data qualifiers in inorganic reports These qualifiers give additional information on the analytes reported The following <br /> is a list of qualifiers and their meanings <br /> I- Sample was analyzed at the stated dilution due to interferences <br /> ' U- Analyte concentration was below the applicable reporting limit For matrix and post digestion spike reports a value of <br /> "0 0"is entered for calculation of the percent recovery <br /> B- Sample concentration was below the reporting limit but above the instrument detection limit Result is entered for <br /> calculation of the percent recovery only <br />' H- Spike percent recovery is not calculated due to possible interferences from relatively high concentration level of the <br /> analyte in the uuspiked sample <br /> Comment Codes <br />' In addition to qualifiers,the following codes are used In the comment section of all reports to give additional information about sample <br /> preparation methods p <br /> A- Sample was prepared for silver based on the silver digestion method developed by the Southern California Laboratory <br /> Department of Health Services "Acrd Ingestion for Sediments Sludges, Sorts and Solid Wastes A Proposed Alternative <br /> to EPA SW846 Method.3050"Environmental Science and Technology 1989,23,898-900 <br /> C- Spikes were prepared after extraction by the California Waste Extraction Test(CWET)method <br /> D- Reported results are dissolved,not total metals Spikes were prepared after filtration <br /> Reporting Conventions <br /> Analytical values reported are gross values i e,not corrected for method blank contamination Solid matrices are reported on a wet <br /> weight basis,unless noted <br /> f tirc[mclmehlslcove[ahllarddoc <br /> J � 05 ? <br />
The URL can be used to link to this page
Your browser does not support the video tag.