Laserfiche WebLink
V <br /> TABLE 3(continued) <br /> VAPOR EXTRACTION OPERATING DATA <br /> MOORE PETROLEUM, INC. <br /> 5491 F Street <br /> Banta, CA <br /> DATE HOUR FLOW ENGINE FLOW EX. INLET STACK COMMENTS <br /> METER PRESS. RPM RATE FLOW FID FID <br /> (in. H2O) (CFM) (SCFM) (ppm) (ppm) <br /> 06/13/96 2328 0.14 2500 19 76 250 5* Collected vapor samples for analysis <br /> 06/26/96 2641 0.12 2100 18 64 300 4* <br /> 07/19/96 3171 0.08 2300 14 70 550 2* Collected vapor samples for analysis <br /> 08/02/96 3385 0.10 2500 16 76 1050 <1* <br /> 08/16/96 3721 0.10 3000 16 91 350 2* Collected vapor samples for analysis <br /> 09/18/96 3720 0.11 2200 17 67 3500 <1* Collected vapor samples for analysis <br /> 10/03/96 3731 0.00 0 0 0 NM NM System down for repairs <br /> FO = Flame out on FID <br /> NM = Not measured <br /> * = Measured with PID <br /> ( ** = Hour meter broken <br /> APEX ENVIROTECH, INC. <br /> FOURTH QUARTER 1996 <br /> ERA02.004 <br />