Laserfiche WebLink
L <br /> µ Sparger Analytical Laboratory Division <br /> Mobile Laboratory Division <br /> Scientfic Division <br /> T <br /> echnob9y lam• <br /> With Automation in Mind <br /> L <br /> r I Sample Description <br /> L p p <br /> See attached Samples Description Information. <br /> The samples <br /> were received under chain-of-custody. <br /> L <br /> r 11 Analysis Request <br /> L The following analytical tests were requested: <br /> LLab ID Your ID Analysis Description <br /> ST95-05-226A INLET TPHgas & BTEX <br /> ST95-05-227A STACK TPHgas & BTEX <br /> LIII Quality Control <br /> A. Proiect Specific QC. No project specific QC (i.e., spikes and/or <br /> Lduplicates) was requested. <br /> B. Method Blank Results. A method blank is a laboratory-generated <br /> L sample which assesses the degree to which laboratory operations and <br /> procedures cause false-positive analytical results for your sample. <br /> LNo target parameters were detected in the method blank associated with <br /> your sample at the reporting limit levels noted on the data sheets in the <br /> LAnalytical Results section. <br /> Accuracy is.measured by Percent Recovery as in: <br /> L o <br /> /o recovery = (measured concentration) x 100 <br /> (actual concentration) <br /> LIV Analysis Results <br /> Results are on the attached data sheets. <br /> L <br /> 3050 Fite Circle, Suite 112 • Sacramento, California 95827 • (916) 362-8947 • FAX (916) 362-0947 <br />