My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0011795
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
F
>
5491
>
3500 - Local Oversight Program
>
PR0545028
>
ARCHIVED REPORTS_XR0011795
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2019 5:12:18 PM
Creation date
12/6/2019 3:45:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0011795
RECORD_ID
PR0545028
PE
3528
FACILITY_ID
FA0003919
FACILITY_NAME
VAN DE POL ENTERPRISES
STREET_NUMBER
5491
STREET_NAME
F
STREET_TYPE
ST
City
BANTA
Zip
95304
CURRENT_STATUS
02
SITE_LOCATION
5491 F ST
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The sampling equipment consists of a"Tedlar"bag(available The probe tip is then lowered into the well and submerged in <br /> in 1,3,5,and 10 liter sizes),a diaphragm pump,and 1144nch- the groundwater. An oscillating(beeping)tone indicates the <br /> diameter polyethylene tubing(appro)amately 1 foot long). probe is in water. The probe is slowly raised until ether the <br /> oscillating tone ceases or becomes a steady tone. In either <br /> The sampling ports are brass connections,fitted with a silicone case,this Is the depth-to-water(DTW)indication and the DTW <br /> septa,and threaded into a tapped hole in the system piping. measurement is made accordingly. The steady tone indicates <br /> The sampling procedure requires one end of the tubing be floating liquid hydrocarbons(FLH). In this case,the probe is <br /> slipped over the sampling port and the other end over the slowly raised until the steady tone ceases. This is the depth-to- <br /> diaphragm pump to acquire an airdigM connection. The product(DTP)indication and the DTP measurement is made <br /> sampling pump is purged for 1 minute with the extracted vapor accordingly. <br /> to be sampled. Following purging,the discharge of the pump <br /> is then diverted through a two-way valve into the"Tedlar"bag, The process of lowering and raising the probe must be <br /> Mich should be filled to 314 of volume capacity. Caution repeated several times to ensure accurate measurements. The <br /> should be taken not to overfill the sampling bag. The sample is DTW and DTP measurements are recorded on the liquid-level <br /> placed in a non-refrigerated dry cooler with sufficient packing to data sheet. When FLH are indicated by the probe's response, <br /> eliminated damage during transport. Cooling samples will a product baiter is lowered partially through the FLH-water <br /> cause condensation of moisture within the sample,thereby interface to confirm the FLH on the water surface and as <br /> distorting laboratory analysis. further indication of the FLH thickness,particularly in cases <br /> where the FLH layer is quite thin. This measurement is <br /> For quality control purposes,a duplicate vapor sample should recorded on the data sheet as"FLH thickness," <br /> be collected from each sampling port This sample is then put <br /> on hold at the laboratory pending initial analysis. To ensure In order to avoid cross-contamination of wells during the liquid- <br /> quality control and minimize the potential for cross- level measurement process,wells are measured in the order of <br /> contamination prior to and during sampling,the diaphragm "clean"to"dirty"(where such information is available). In <br /> pump is thoroughly purged for approbmately 5 minutes with addition,all measurement equipment is cleaned with solution <br /> nitrogen or clean air(i.e.,compressed clean air), A"blame' and thoroughly rinsed with deionized water before use,between <br /> sample of the discharged air is raptured in a'Tedlar"bag at measurements in respective wells,and at the completion of the <br /> the end of the purging procedure and may be analyzed to day's use. <br /> ensure the purging was effective. <br /> To minimize the potential for cross-contamination between air <br /> samples,the polyethylene tubing,if not sample dedicated,is <br /> thoroughly cleaned and rinsed. <br /> Vapor samples are subject to very limited holding times, <br /> typically 48 hours. Thus,care must taken to avoid delays in <br /> '1 submittal of vapor samples to the laboratory. In the event the <br /> vapor samples cannot be submitted to the analytical laboratory <br /> on the same day they are collected,they are to be temporarily <br /> erated packed cooler until the very <br /> stored in the dry,non-refig ,p <br /> first opportunity for submittal welt within the required holding <br /> time,taWng into account the time needed for shipment to and <br /> receipt by the laboratory. <br /> SOP-1 2 <br /> MEASURING LIQUID LEVELS USING <br /> WATER LEVEL METER OR INTERFACE <br /> PROBE <br /> Field equipment used for liquid-level gauging typically includes <br /> the measuring instrument(water-level meter or interface probe) <br /> and product bailer(s). The field kit also includes cleaning <br /> supplies(buckets,solution,spray bottles,and deionized water) <br /> to be used in cleaning the equipment between wells. <br /> Prior to measurement,the instrument tip is lowered into the well <br /> until it touches bottom. Using the previously established top-of- <br /> casing or top-of-box(i.e.,wellhead vaulty point,the probe cord <br /> (or halyard)is marked and a measuring tape(graduated in <br /> hundredths of a foot)is used to determine the distance <br /> between the probe end and the marking on the cord. This <br /> measurement is then recorded on the liquid-level data sheet as <br /> the"Measured Total Depth"of the well. <br /> When necessary in using the Interface probe to measure liquid <br /> levels,the probe is first electrically grounded to either the metal <br /> stove pipe or another metal object nearby. When no ground is <br /> available,reproducible measurements can be obtained by <br /> clipping the ground lead to the handle of the interface probe <br /> case. <br /> Page 2-SOP Operation 8 Maintenance <br />
The URL can be used to link to this page
Your browser does not support the video tag.