Laserfiche WebLink
1 I <br /> APEX ENVIROTECH, INC. <br />{ STANDARD OPERATING PROCEDURES <br /> I Quarterly Monitoring Reports <br /> SOP - 4 When practical,the groundwater sample should be collected <br />} SAMPLE IDENTIFICATION AND CHAIN- when the water level in the well recovers to at least 80 percent <br /> OF-CUSTODY PROCEDURES of its static level. <br /> 1The sampling equipment consists of either a`Teflon"bailer, <br /> Sample identification and chain-0f-custody procedures ensure PVC bailer,or stainless steel bladder pump with a"Teflon' <br /> sample integrity as well as document sample possession from bladder. If the sampling system is dedicated to the well,then } <br /> the time of collection to ultimate disposal. Each sample the bailer Is usually"Teflon,"but the bladder pump is PVC with 1 <br /> container submitted for analysis is labeled to Identify the job a polypropylene bladder. In general and depending on the f <br /> number,date,time of sample collection,a sample number intended laboratory analysis,40-milliliter glass,volatile organic <br /> . unique to the sample,any in-field measurements made, analysis(VOA)vials,with"Teflon"septa,are used as sample <br /> sampling methodology,name(s)of on-site personnel,and any containers. <br /> other pertinent field observations also recorded on the field <br /> excavation or boring log. SOP - 112 <br /> MEASURING LIQUID LEVELS USING <br /> Chain-of-custody forms are used to record possession of the WATER LEVEL METER OR INTERFACE <br /> sample from time of collection to arrival at the laboratory, PRO113E <br /> During shipment,the person with custody of the samples will 1 <br /> relinquish them to the next person by signing the chain-of- Field equipment used for liquid-levei gauging typically includes <br /> custody form(s)and noting the date and time. The sample- the measuring instrument(water-level meter or interface probe) <br /> control officer at the laboratory will verify sample integrity, and product bailer(s). The field kit also includes cleaning_ <br /> correct preservation,confirm collection In the proper supplies(buckets,solution,spray bottles,and deionized water) ! <br /> container(s),and ensure adequate volume for analysis. to be used in cleaning the equipment between wells. <br /> If these conditions are met,the samples will be assigned Prier to measurement,the instrument Up is lowered into the well <br /> unique laboratory log numbers for identification throughout until it touches bottom. Using the previously established top-of- 3 <br /> analysis and reporting. The log numbers will be recorded on casing or top-of-box(i.e.,wellhead vault)point,the probe cord ; <br /> 6 the chain-of-custody forms and In the legally-required log book (or halyard)Is marked and a measuring tape(graduated In <br /> maintained in the laboratory. The sample description,date hundredths of a foot)Is used to determine the distance <br /> received,clients name,and any other relevant information will between the probe end and the marking on the cord. This <br /> also be recorded. measurement Is then recorded on the liquid-level data sheet as <br /> the"Measured Total Depth'of the well. <br />` SOP - S <br /> l When necessary in using the interface probe to measure liquid <br /> LAIBORATORY ANALYTICAL QUALITY levels,the probe is first electrically grounded to either the metal <br /> ASSURANCE AND CONTROL stove pipe or another metal object nearby. When no ground is <br /> available,reproducible measurements can be obtained by <br /> In addition to routine instrument calibration,replicates,spikes, gipping the ground lead to the handle of the interface probe <br /> blanks,spiked blanks,and certified reference materials are case. <br /> routinely analyzed at method-specific frequencies to monitor <br /> precision and bias. Additional components of the laboratory The probe tip is then lowered into the well and submerged In <br /> Quality Assurance/Quality Control program include: the groundwater. An oscillating(beeping)tone indicates the <br /> k probe is in water. The probe is slowly raised until either the <br /> 1 i. Participation in state and federal laboratory oscillating tone ceases or becomes a steady tone. In either <br /> accreditation/certification programs; case,this is the depth-to-water(DTW)indication and the DTW <br /> measurement is made accordingly. The steady tone Indicates <br /> 2. Participation in both U.S.EPA Performance floating liquid hydrocarbons(FLH). In this case,the probe is <br /> Evaluation studies(WS and WP studies)and inter- slowly raised until the steady tone ceases. This Is the depth-to- <br /> laboratory performance evaluation programs; product(DTP)indication and the DTP measurement Is made <br /> accordingly. <br /> 3. Standard operating procedures describing routine <br /> and periodic instrument maintenance; The process of lowering and raising the probe must be <br /> repeated several times to ensure accurate measurements. The <br /> DTW and DTP measurements are recorded on the liquid-level <br /> 4. "Out-of-ControE"ICarrective Action documentation <br /> procedures;and, data sheet. When FLH are indicated by the probe's response, <br /> a product bailer is lowered partially through the FLH-water <br /> 5. MutWevel review of raw data and client reports. interface to confirm the FLH on the water surface and as. } <br /> further indication of the FLH thickness,particularly In cases <br /> SOP - 7 where the FLH layer is quite thin. This measurement Is <br /> GROUNDWATER PURGING AND recorded on the data sheet as"FLH thickness" <br /> SAMPLING <br /> In order to avoid cross-contamination of welts during the ltquid- <br /> Prior to water sampling,each well is purged by evacuating a level measurement process,wells are measured in the order of <br />{I. minimum of three wetted well-casing volumes of groundwater. "clean"to"dirty"(where such information Is available). In <br /> When required,purging will continue until either the discharge addition,all measurement equipment Is cleaned with solution <br /> water temperature,conductivity,or pH stabilize,a maximum of and thoroughly rinsed with deionized water before use,between <br /> ten wetted-casing volumes of groundwater have been measurements In respective wells,and at the completion of the <br /> recovered,or the well is bailed dry. days use. <br /> i <br />