APEX ENVIROTECH, INC.,
<br /> STANDARD OPERATING PROCEDURES
<br /> Quarterly Monitoring Reports
<br /> recovered,or the well is bailed dry. When practical,the
<br /> groundwater sample should be collected when the water level in
<br /> SOP - 4 the well recovers to at least 80 percent of its static level,
<br /> SAMPLit~ 1K)KNTIFIOA1rION AND•OFiA1N-
<br /> OlR-oU STODY PROO>4DIrRxis The sampling equipment consists of either a'Teflori bailer.PVC
<br /> p dy procedures ensure bailer,or stainless steel bladder pump with a'Teflon'bladder. If
<br /> Sample n egrity as
<br /> and documents a the sampling system is dedicated to the well,then the bailer is
<br /> sample Integrity es well as document sample possession from the
<br /> time or collection to ultimate disposal. Each sample container usually`Teflon;but the bladder pump 4 PVC with a
<br /> submitted for analysis Is labeled to identify the job number,date, polypropylene bladder. In general and depending on the intended
<br /> time of sample collection,a sample number unique to the sample, laboratory analysis,40-milliliter glass,volatile organic analysis
<br /> any In-field measurements made,sampling methodology,name(s) (VOA)vials,with'Teflon'septa,are used as sample containers.
<br /> of on-site personnel,and any other pertinent field observations also
<br /> recorded on the field excavation or boring log. SOP - 7 3z
<br /> MILASURINQ L1Q1UJD Lt♦1i►rMLS USING
<br /> Chain-of-custody forms are used to record possession of WATMER LttdVAEL MIKTHR OR 1NTBF1PrAOIt
<br /> thosample from time of collection to arrival at the laboratory. PR OIIH
<br /> During shipment,the person with custody of the samples Wit
<br /> relinquish them to the next person by signing the chaln-okustody Field equipment used for ti uid-level au in
<br /> g typically includes the
<br /> form(s)and noting the date and time. The sample-control officer measuring instrument(water-tevel meter or interfacerobe)and
<br /> at the laboratory will verify sample integrity,correct preservation, product bailer(s). The field kit also includes cleaning su
<br /> confirm collection in the proper container(s),and ensure adequate 9 pplies
<br /> (buckets,solution,spray bottles,and deiontzed water to be used
<br /> volume for analysis. In cleaningthe )
<br /> equipment between welts.
<br /> If these conditions are met,the samples Wit be assigned unique
<br /> laboratory log numbers for Identification throughout analysis and Prior to measurement,the Instrument tip is lowered Into the well
<br /> reporting. The log numbers will be recorded on the chaln-of- until it touches bottom. Using the previously established top-of-
<br /> custody
<br /> op-0tcustody forms and in the Inalty-required log book maintain ad in casing or top-of-box(.e.,wellhead vault)point,the probe cord(or r
<br />` the laboratory. The sample description,date received,client's halyard)Is marked and a measuring tare(graduated In hundredths
<br /> name,and any other relevant information will also be recorded, of a foot)is used to determine the distance between the probe end
<br /> and the marking on the cord. This measurementdsthen recorded
<br /> SOP - G on the liquid-level data shoot as the*measured Total Depth`of the
<br /> LA13ORA'rORY ANALYTIOAL QUALITY welt.
<br /> ASSURANOR AND OONTROL
<br /> in addition to routine Instrument calibration,replicates,spikes, When necessary in using the interface probe to measure liquid
<br /> blanks,spiked blanks,and certified reference materials are levels,the probe Is first electrically grounded to either the metal
<br /> routinely analyzed at method-specific frequencies to monitor stove pipe or another metal object nearby. When no ground is
<br /> precision and bias. Additional components of the laboratory available,reproducible measurements can be obtained by clipping
<br /> Quality AssurancelQuality Control program include: the ground lead to the handle of the interface probe case.
<br /> 1. Participation to state and federal laboratory The probe tip Is then lowered into the wall and submerged In the
<br /> accreditation/certification programs; groundwater. An oscillating(beeping)tone Indicates the probe is
<br /> In water. The probe Is slowly raised until either the oscillating tone
<br /> 2. Participation in both U.S.EPA Performance Evaluation ceases or becomes a steady tone. In either lase,this Is the
<br /> studies(WS and WP studies)and inter-laboratory depth-to-water(OTM Indication and the DTW measurement 4
<br /> performance evaluation programs; made accordingly. The steady tone indicates floating liquid
<br /> 3. Standard operating procedures describing routine and hydrocarbons(FLH). In this case,the probe is slowly raised until
<br />` . periodic instrument maintenance; the steady tone ceases. This is the depth-to-product(DTP)
<br /> Indication and the DTP measurement Is made accordingly.
<br /> 4. 'Out-orControl'iCorractive Action documentallon
<br /> procedures;and. The process of lowering and raising the probe must be repeated
<br /> several times to ensure accurate measurements. The DTW and
<br /> S. Multi-levet review of raw data and client reports. DTP measurements are recorded on the liquid-level data sheet.
<br /> When FLH are Indicated by the probe's response,a product bailer
<br /> SOP - q Is lowered partially through the FLH water Interface to confirm the
<br /> GROUNDWATER PURGING AND FLH on the water surface and as further Indication afthe FLH
<br /> SAMPLING thickness,particularly In cases where the'FLH layerls quite thin.
<br /> This measurement Is recorded on the data sheet as'FLH
<br /> Prior to water sampling,each well is purged by evacuating a thickness.'
<br /> minimum of three wetted wall-casing volumes of groundwater.
<br /> When required,purging will continue until either the In order to avoid eress-contamination of wells during the Gquid-
<br /> dischargethree wetted wall-casing volumes of groundwater. level measurement process,wells are measured in the order or
<br /> When required,purging will continue until either the discharge 'clean'to'dirty'(where such information is available). Inaddition,
<br /> water temperature,conductivi-[y,or pH stabilize,a maximum of all measurement equipment is cleaned with solution and
<br /> ten wetted-casing volumes of groundwater have been thoroughly rinsed with dsionized water t)-afore use,between
<br /> measurements in respective wells,and at the completion of the
<br /> day's use.